The effect of using basalt fibers on the fresh, mechanical, durability, and corrosion properties of reinforced concrete was investigated in this study. The study was performed using different basalt fiber volume fractions of 0.15%, 0.30%, 0.45%, and 0.50%, while two different water/cement (w/c) ratios of 0.35 and 0.40 were utilized. The results were compared to conventional concrete (PC) as well as steel fiber concrete (SFC) with 0.30% and 0.50% steel fibers volume fractions. An extensive experimental program of 336 samples was conducted in four stages as follows: testing for fresh properties included slump and unit weight tests; mechanical properties testing included compressive strength tests, split tensile strength tests, flexural strength tests, and average residual strength tests; durability testing included unrestrained shrinkage and surface resistivity tests; and a Rapid Macrocell corrosion evaluation test for corrosion properties. The test results showed that the use of basalt fibers reduces slump values as the fiber volume fraction increases; however, with the use of the appropriate amount of High Range Water Admixture (HRWA), target slump values can be achieved. Moreover, a considerable improvement in the compressive, tensile, flexural, average residual strength and durability properties was achieved in case of using basalt fibers. On the other hand, corrosion rates increased with the increase in fiber volumes. However, it can be concluded that utilizing a 0.30% fibers volume fraction is the optimum ratio with an overall acceptable performance with respect to mechanical and corrosion properties.
Energy consumption, specifically in the building sector, is expected to rise. One potential way to reduce energy consumption, or to slow this increase, is to reduce the heat loss in residential homes. Silica aerogels have grown in popularity as an insulating material due to their extremely low thermal conductivity. However, the benefits of using silica aerogels as an insulator in residential buildings have not been thoroughly studied. To understand the benefits of using silica aerogels as a thermal insulator in residential homes, experimentally validated simulations were performed. The simulations were performed on a model of a full-scale residential house using the multiphysics software ANSYS FLUENT 2019 R2. The simulations helped predict the actual saving benefits of using aerogels as an insulator. Aerogels have the potential to be used as an insulator in both the walls and windows due to its semitransparency. The results showed that the average kWh savings using one half-inch layer of wall aerogel insulation coupled with window aerogel insulation was 20.9% for the single-family house compared to traditional insulation. On average, the energy lost through the windows was 39.1% lower when using aerogel insulation compared to standard insulating materials. The energy lost through the house walls was 13.3% lower on average when using a thin layer of aerogel insulation. While a thin layer of aerogel insulation provided a benefit when used in the house walls, the potential for savings per quantity used was greater in the windows.
16 February 2021 in International Journal of Concrete Structures and Materials
The shear span-to-effective depth ratio (a/d) is one of the factors governing the shear behavior of reinforced concrete (RC) beams, with or without shear reinforcement. In high-strength concrete (HSC), cracks may propagate between the aggregate particles and result in a brittle failure which is against the philosophy of most design guidelines. The experimental results of six HSC beams, with and without shear reinforcement, tested under four-point bending with a/d ranged from 2.0 to 3.0 are presented and compared with different model equations in design codes. The a/d ratio has higher influence on the shear strength of reinforced HSC beams without shear reinforcement than beams with shear reinforcement. Most of the shear resistance prediction models underestimate the concrete shear strength of the beams but overpredict shear resistance of beams with shear reinforcement. However, the fib Model code 2010 accurately predicted the shear resistance for all the beams within an appropriate level of approximation (LoA).
16 August 2018 in International Journal of Civil Engineering