Plate heat exchangers have the advantages of high heat transfer coefficients and compact structures, and they are widely used in aerospace, nuclear power, and other fields. Nevertheless, several scalability challenges have emerged during the utilization process. If not addressed promptly, the issue will reduce heat transfer efficiency, consequently causing energy waste, diminished production capacity, and a shortened lifespan. In this study, we employed the long short-term memory (LSTM) algorithm model and the multi-layer perceptron (MLP) algorithm model to monitor the health status of plate heat exchangers. This was achieved by fine-tuning the hidden layers and neurons of the models. The individual model exhibiting the highest prediction accuracy was incorporated into a more sophisticated ensemble model to monitor the health status of plate heat exchangers. The study revealed that the MLP 2 × 64 + LSTM 2 × 64 model achieved the highest prediction accuracy, scoring 0.9942. According to the simulation program for plate heat exchangers, the fouling thermal resistance was determined to be 0.0003 m2·K/W when the heat exchange efficiency decreased by 50%. An early warning threshold was established within the health condition value (HCV), triggering an alert when the heat transfer efficiency of the plate heat exchanger fell below 50%. Combining the LSTM and MLP algorithms provides new ideas and technical support for the health assessment and maintenance of plate heat exchangers.
Accurate and rapid forecasting of short-term loads facilitates demand-side management by electricity retailers. The complexity of customer demand makes traditional forecasting methods incapable of meeting the accuracy requirements, so a self-attention based short-term load forecasting (STLF) considering demand-side management is proposed. In the data preprocessing stage, non-parametric kernel density estimation is used to construct customer electricity consumption feature curves, and then historical load data are used to delineate the feasible domain range for outlier detection. In the feature selection stage, the feature data are selected using variational modal decomposition and a maximum information coefficient to enhance the model prediction accuracy. In the model prediction stage, the decomposed intrinsic mode function components are independently predicted and reconstructed using an Informer based on improved self-attention. Additionally, the novel AdaBlief optimizer is used to optimize the model parameters. Cross-sectional and longitudinal experiments are conducted on a regional-level load dataset set in Spain. The experimental results prove that the proposed method is superior to other methods in STLF.
1 January 2025 in Protection and Control of Modern Power Systems
In general, the seasonal characteristics of small hydropower (SHP) especially the power transmission during the summer flood season would lead to the steady overvoltage of the distribution network. In order to suppress this steady overvoltage, a strategy for coordinated cooperation between generator phase-in operation and shunt reactors which can be called cooperative control is proposed. The distribution network of SHP stations connected to the 35 kV Bantao substation in southern Shaanxi is taken as an example to study the mechanism of overvoltage after the SHP is connected to the grid. A distribution network model with SHP units is established. Based on the model, the effect of separately installing shunt reactors on the node voltage is studied in the case of generator lag phase operation and the influence of the operation mode of SHP unit on the node voltage is also analyzed separately. Finally, the improvement measures of cooperative control between the generator phase-in operation and the parallel reactors are analyzed by simulation. Results are presented to verify the improvement measures that can effectively restrain the overvoltage of the distribution network in the SHP area.