Chinh Nguyen

Dr. Chinh Nguyen


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2014 in Materials and Structures
Verified
Journal Article
Closed access
PDF file
PLPaul Lambert
Paul Lambert
CNChinh Nguyen
Chinh Nguyen
PMPritpal Mangat
Pritpal Mangat
FOFinbar J. O’flaherty
Finbar J. O’flaherty
GJGraeme Jones
Graeme Jones

19 March 2018 in Structure and Infrastructure Engineering
Verified
Journal Article
Closed access
CNChinh Nguyen
Chinh Nguyen
PLPaul Lambert
Paul Lambert
Impressed anodic current techniques are used widely to accelerate corrosion of steel embedded in concrete in the laboratory. This paper investigates the relationship between applied current density, degree of corrosion, type of corrosion and ultimate strength of corroded beams. Twenty beams were divided into four groups with a 0.5, 1, 2.5 or 5% degree of corrosion. Current densities of 0.25, 0.5, 1.0 or 2.5 mA/cm2 were applied to each group, respectively. The beams were flexurally tested and the reinforcing steel bars were retrieved, cleaned, weighed and the surface examined. The results demonstrated that higher current densities and degree of corrosion caused more localised corrosion. The applied current density has little effect on the degree of corrosion and on ultimate strength of the same degree of corroded beam. Based on this work, a current density of 1 mA/cm2 is recommended for the artificial acceleration of corrosion for steel embedded in concrete.

16 February 2019 in Materials
Verified
Journal Article
Open access
PDF file
CNChinh Nguyen
Chinh Nguyen
PLPaul Lambert
Paul Lambert
QTQuang Hung Tran
Quang Hung Tran
Vietnamese fly ash was used as a partial replacement for ordinary Portland cement in the proportions of 10%, 20% and 40%, while the water to cementitious ratios were kept constant at 0.42, 0.5 and 0.55, respectively, for three groups. The compressive strengths of all mixes were determined up to 90 days. The acid resistance of fly ash concrete was examined by the mass loss and compressive strength loss of 100 × 100 × 100 mm3 cubes immersed in a 10% H2SO4 solution. The probability of steel corrosion in the fly ash concrete was assessed by measuring the half-cell potentials of steel bars within beams dimensions of 100 × 100 × 500 mm3, and the flexural strengths of these beams after 300 days of immersion in a 5% NaCl solution were determined. The results demonstrate that the compressive strength of fly ash concrete is reduced at an early age but increases as the concrete continues to hydrate. The fly ash increases the sulfuric acid resistance of concrete. Fly ash additions have only a limited effect on reducing the risk of probability of corrosion of steel in the concrete. The load capacities of 10% and 20% fly ash reinforced concrete beams are higher than that of the control beams after 300 days immersed in a 5% NaCl solution.

20 December 2012 in ISRN Corrosion
Verified
Journal Article
Open access
PDF file
CNChinh Nguyen
Chinh Nguyen
PLPaul Lambert
Paul Lambert
PMPal Mangat
Pal Mangat
FOFin O’flaherty
Fin O’flaherty
GJGraeme Jones
Graeme Jones
Cathodic protection has been proven to be one of the most widely applicable and cost-effective solutions for tackling steel corrosion in reinforced concrete. In this study, the possible use of carbon fibre composites, which are primarily used to strengthen concrete members, has been investigated as impressed current cathodic protection anodes. Carbon fibre anodes have been assessed in both concrete and calcium hydroxide solution. Two bonding mediums incorporating epoxy and geopolymer have also been investigated. The results demonstrate that epoxy resin can be used for bonding carbon fibre fabric anodes to reinforced concrete structures while geopolymer is more effective for bonding carbon fibre reinforced polymer (CFRP) rod into preformed grooves in the concrete surface. The dissolution of carbon fibre anode appears to stablise after a period of time, dependent upon the size and shape of the anode and applied voltage and current. Based on the present results, a maximum current density of 128 mA/m2of reinforcing steel area is recommended for the operation of CFRP fabric anode and 64 mA/m2of reinforcing steel area for that of CFRP rod anode.

14 January 2020 in International Journal of Civil Engineering
Verified
Journal Article
Closed access
PDF file
CNChinh Nguyen
Chinh Nguyen
PLPaul Lambert
Paul Lambert
VBVu Ngoc Bui
Vu Ngoc Bui

3 March 2015 in Structure and Infrastructure Engineering
Verified
Journal Article
Closed access
CNChinh Nguyen
Chinh Nguyen
PLPaul Lambert
Paul Lambert
PMPritpal S. Mangat
Pritpal S. Mangat
FOFin J. O'FLaherty
Fin J. O'FLaherty
GJGraeme Jones
Graeme Jones