Jakob Wilm

Dr. Jakob Wilm

Syddansk Universitet
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2013 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
MFMads Fogtmann
Mads Fogtmann
SSSharmishtaa Seshamani
Sharmishtaa Seshamani
CKChristopher Kroenke
Christopher Kroenke
XCXi Cheng
Xi Cheng
TCTeresa Chapman
Teresa Chapman
CSColin Studholme
Colin Studholme
This paper presents an approach to 3-D diffusion tensor image (DTI) reconstruction from multi-slice diffusion weighted (DW) magnetic resonance imaging acquisitions of the moving fetal brain. Motion scatters the slice measurements in the spatial and spherical diffusion domain with respect to the underlying anatomy. Previous image registration techniques have been described to estimate the between slice fetal head motion, allowing the reconstruction of 3D a diffusion estimate on a regular grid using interpolation. We propose Approach to Unified Diffusion Sensitive Slice Alignment and Reconstruction (AUDiSSAR) that explicitly formulates a process for diffusion direction sensitive DW-slice-to-DTI-volume alignment. This also incorporates image resolution modeling to iteratively deconvolve the effects of the imaging point spread function using the multiple views provided by thick slices acquired in different anatomical planes. The algorithm is implemented using a multi-resolution iterative scheme and multiple real and synthetic data are used to evaluate the performance of the technique. An accuracy experiment using synthetically created motion data of an adult head and an experiment using synthetic motion added to sedated fetal monkey dataset show a significant improvement in motion-trajectory estimation compared to current state-of-the-art approaches. The performance of the method is then evaluated on challenging but clinically typical in utero fetal scans of four different human cases, showing improved rendition of cortical anatomy and extraction of white matter tracts. While the experimental work focuses on DTI reconstruction (second-order tensor model), the proposed reconstruction framework can employ any 5-D diffusion volume model that can be represented by the spatial parameterizations of an orientation distribution function.

7 April 2016 in The International Archives of the Photogrammetry, Remote Sensing and Spatial Information Sciences
Verified
Journal Article
Open access
PDF file
EEE. R. Eiríksson
E. R. Eiríksson
JWJakob Wilm
Jakob Wilm
DPDavid B. Pedersen
David B. Pedersen
HAH. Aanæs
H. Aanæs
Structured light systems are popular in part because they can be constructed from off-the-shelf low cost components. In this paper we quantitatively show how common design parameters affect precision and accuracy in such systems, supplying a much needed guide for practitioners. Our quantitative measure is the established VDI/VDE 2634 (Part 2) guideline using precision made calibration artifacts. Experiments are performed on our own structured light setup, consisting of two cameras and a projector. We place our focus on the influence of calibration design parameters, the calibration procedure and encoding strategy and present our findings. Finally, we compare our setup to a state of the art metrology grade commercial scanner. Our results show that comparable, and in some cases better, results can be obtained using the parameter settings determined in this study.

19 September 2017 in Applied Optics
Verified
Journal Article
Closed access
PDF file
JSJonathan Dyssel Stets
Jonathan Dyssel Stets
ACAlessandro Dal Corso
Alessandro Dal Corso
JNJannik Boll Nielsen
Jannik Boll Nielsen
RLRasmus Ahrenkiel Lyngby
Rasmus Ahrenkiel Lyngby
SJSebastian Hoppe Nesgaard Jensen
Sebastian Hoppe Nesgaard Jensen
HAHenrik Aanæs
Henrik Aanæs
Transparent objects require acquisition modalities that are very different from the ones used for objects with more diffuse reflectance properties. Digitizing a scene where objects must be acquired with different modalities requires scene reassembly after reconstruction of the object surfaces. This reassembly of a scene that was picked apart for scanning seems unexplored. We contribute with a multimodal digitization pipeline for scenes that require this step of reassembly. Our pipeline includes measurement of bidirectional reflectance distribution functions and high dynamic range imaging of the lighting environment. This enables pixelwise comparison of photographs of the real scene with renderings of the digital version of the scene. Such quantitative evaluation is useful for verifying acquired material appearance and reconstructed surface geometry, which is an important aspect of digital content creation. It is also useful for identifying and improving issues in the different steps of the pipeline. In this work, we use it to improve reconstruction, apply analysis by synthesis to estimate optical properties, and to develop our method for scene reassembly.

24 April 2020 in Robotica
Verified
Journal Article
Open access
PDF file
LEL.-P. Ellekilde
L.-P. Ellekilde
JWJakob Wilm
Jakob Wilm
ONO. W. Nielsen
O. W. Nielsen
CKC. Krogh
C. Krogh
EKE. Kristiansen
E. Kristiansen
Henrik Gordon PetersenHenrik Gordon Petersen
Henrik Gordon Petersen
SUMMARY This paper presents a novel solution for precision draping of prepreg composite fabrics onto double curved molds. Our contributions relate to system design, including hardware and software components, and to system integration. On the hardware side, design and implementation of a drape tool with up to 120 suction cups positioned individually by linear actuators are described. On the software side, design and implementation of the software architecture are presented, along with necessary algorithms within sensor technologies and mathematical modeling. The essential system’s components were verified individually, and the entire integrated system was successfully validated in the Proof-of-Concept experiments, performed on an experimental physical model of the system.

4 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JJJanus Nørtoft Jensen
Janus Nørtoft Jensen
MHMorten Rieger Hannemose
Morten Rieger Hannemose
ABAndreas Bærentzen
Andreas Bærentzen
JWJakob Wilm
Jakob Wilm
Jeppe Revall FrisvadJeppe Revall Frisvad
Jeppe Revall Frisvad
ADAnders Dahl
Anders Dahl
When 3D scanning objects, the objective is usually to obtain a continuous surface. However, most surface scanning methods, such as structured light scanning, yield a point cloud. Obtaining a continuous surface from a point cloud requires a subsequent surface reconstruction step, which is directly affected by any error from the computation of the point cloud. In this work, we propose a one-step approach in which we compute the surface directly from structured light images. Our method minimizes the least-squares error between photographs and renderings of a triangle mesh, where the vertex positions of the mesh are the parameters of the minimization problem. To ensure fast iterations during optimization, we use differentiable rendering, which computes images and gradients in a single pass. We present simulation experiments demonstrating that our method for computing a triangle mesh has several advantages over approaches that rely on an intermediate point cloud. Our method can produce accurate reconstructions when initializing the optimization from a sphere. We also show that our method is good at reconstructing sharp edges and that it is robust with respect to image noise. In addition, our method can improve the output from other reconstruction algorithms if we use these for initialization.

7 March 2014
Verified
Conference Paper
Closed access
PDF file
JWJakob Wilm
Jakob Wilm
OOOline V. Olesen
Oline V. Olesen
RLRasmus Larsen
Rasmus Larsen
Much work has been devoted to the calibration of optical cameras, and accurate and simple methods are now available which require only a small number of calibration targets. The problem of obtaining these parameters for light projectors has not been studied as extensively and most current methods require a camera and involve feature extraction from a known projected pattern. In this work we present a novel calibration technique for DLP Projector systems based on phase shifting profilometry projection onto a printed calibration target. In contrast to most current methods, the one presented here does not rely on an initial camera calibration, and so does not carry over the error into projector calibration. A radial interpolation scheme is used to convert features coordinates into projector space, thereby allowing for a very accurate procedure. This allows for highly accurate determination of parameters including lens distortion. Our implementation acquires printed planar calibration scenes in less than 1s. This makes our method both fast and convenient. We evaluate our method in terms of reprojection errors and structured light image reconstruction quality.