Rotating machinery in cold and humid regions is prone to icing. For exploring the characteristics of icing on objects rotating around a vertical axis, such as vertical axis wind turbines (VAWT), a cylinder rotating around the vertical axis was selected as the research object in this study. Three cylinders with different diameters were selected, and icing tests carried out under different tip speed ratios (TSR) in a self-built icing wind tunnel. The icing characteristics were quantitatively analyzed using characteristic parameters, including the icing area, the dimensionless icing area, the stagnation point thickness and the dimensionless stagnation point thickness. The dimensionless stagnation point thickness decreased with increases in the diameter of the cylinder. The icing limit decreased with an increase in the rotational speed of the cylinder, and reached 50% under the high TSR condition. Various icing characteristics were also analyzed for two rotation modes: rotation around the vertical axis and around the horizontal axis. The research findings in the present study lay the theoretical and experimental foundations for exploring VAWT icing in depth.
8 July 2008 in Frontiers of Energy and Power Engineering in China
The asymmetric faults often cause the power grid current imbalance and power grid oscillation, which brings great instability risk to the power grid. To address this problem, this paper presented a modeling and parameter optimization method of grid-connected photovoltaic (PV) systems, considering the low voltage ride-through (LVRT) control. The harmonics of the grid current under asymmetric faults were analyzed based on the negative-sequence voltage feedforward control method. The notch filter was added to the voltage loop to filter out the harmonic components of the DC bus voltage and reduce the harmonic contents of the given grid current value. The proportional resonant (PR) controller was added to the current loop. The combination of these two components could reduce the 3rd, 5th, and 7th harmonics of the grid current and the output power fluctuation. Then, the parameters of the inverter controller were identified by the adaptive differential evolution (ADE) algorithm based on the sensitivity analysis. The effectiveness of the proposed method was compared with two other strategies under the asymmetric grid faults. The suppression of DC bus voltage fluctuation, power fluctuation, and low-order harmonics of the grid current all had better results, ensuring the safe and stable operation of the PV plant under grid faults.