James McGrath

Dr. James McGrath

School of Physics & Ryan Institute’s Centre for Climate and Air Pollution Studies, National University of Ireland Galway, H91 CF50 Galway, Ireland
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2019 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
JMJames McGrath
James McGrath
AOAndrew O'Sullivan
Andrew O'Sullivan
GBGavin Bennett
Gavin Bennett
COCiarraí O'Toole
Ciarraí O'Toole
MJMary Joyce
Mary Joyce
Ronan MacLoughlinRonan MacLoughlin
Ronan MacLoughlin
Background: Secondary inhalation of medical aerosols is a significant occupational hazard in both clinical and homecare settings. Exposure to fugitive emissions generated during aerosol therapy increases the risk of the unnecessary inhalation of medication, as well as toxic side effects. Methods: This study examines fugitively-emitted aerosol emissions when nebulising albuterol sulphate, as a tracer aerosol, using two commercially available nebulisers in combination with an open or valved facemask or using a mouthpiece with and without a filter on the exhalation port. Each combination was connected to a breathing simulator during simulated adult breathing. The inhaled dose and residual mass were quantified using UV spectrophotometry. Time-varying fugitively-emitted aerosol concentrations and size distributions during nebulisation were recorded using aerodynamic particle sizers at two distances relative to the simulated patient. Different aerosol concentrations and size distributions were observed depending on the interface. Results: Within each nebuliser, the facemask combination had the highest time-averaged fugitively-emitted aerosol concentration, and values up to 0.072 ± 0.001 mg m−3 were recorded. The placement of a filter on the exhalation port of the mouthpiece yielded the lowest recorded concentrations. The mass median aerodynamic diameter of the fugitively-emitted aerosol was recorded as 0.890 ± 0.044 µm, lower the initially generated medical aerosol in the range of 2–5 µm. Conclusions: The results highlight the potential secondary inhalation of exhaled aerosols from commercially available nebuliser facemask/mouthpiece combinations. The results will aid in developing approaches to inform policy and best practices for risk mitigation from fugitive emissions.

15 November 2022 in Toxics
Verified
Journal Article
Open access
PDF file
Alison ConnollyAlison Connolly
Alison Connolly
Holger KochHolger Koch
Holger Koch
DBDaniel Bury
Daniel Bury
SKStephan Koslitz
Stephan Koslitz
MKMarike Kolossa-Gehring
Marike Kolossa-Gehring
MCMarie A. Coggins
Marie A. Coggins
Glyphosate-based pesticides are the highest-volume used herbicides worldwide. International concerns regarding the potential human adverse effects of glyphosate exposures have heightened since IARC classified glyphosate as probably carcinogenic to humans. Human biomonitoring (HBM) studies have identified ubiquitous exposure to glyphosate and its main breakdown product, aminomethylphosphonic acid (AMPA), from environmental exposures. The IMAGE research project aimed to investigate farm and non-farm families’ exposure to glyphosate while aligning with the Human Biomonitoring for Europe (HBM4EU) initiative. The study recruited non-farm and farm families (who use glyphosate on their farms). Each family member provided a urine sample that was analysed using gas chromatography coupled with tandem mass spectrometry, with a limit of quantification of 0.05 µg/L for glyphosate and AMPA. In addition to general information on background exposures in farm and non-farm families, we investigated relationships in exposure between families and family members. We recruited 68 families, including 54 non-farm and 14 farm families (180 vs. 45 individuals). Some pesticide users (n = 14, all male farmers) had slightly elevated AMPA levels compared to other adult participants but, overall, we observed no significant differences between farm and non-farm families. The main metabolite, AMPA, was quantifiable in twice as many samples as glyphosate (61% vs. 32%), with a maximum concentration of 7.24 µg/L vs. 3.21 µg/L. Compared to previous studies, exposure levels were relatively low and far below current health-based guidance values (3% or less for glyphosate and AMPA). Study results suggest potential exposures from residential co-exposures or living with a pesticide user. This is the first study internationally to investigate glyphosate and AMPA across family members (farm and non-farm). We found comparably low glyphosate and AMPA exposures among these families. These results enhance our understanding of glyphosate exposures for different demographic groups and contribute to the scientific knowledge on exposures required for regulatory risk assessments and the re-evaluation of glyphosate in 2022 by the European Commission.

1 May 2021 in Building and Environment
Verified
Journal Article
Open access
JMJames McGrath
James McGrath
Reihaneh AghamolaeiReihaneh Aghamolaei
Reihaneh Aghamolaei
JOJames O'Donnell
James O'Donnell
MBMiriam A. Byrne
Miriam A. Byrne

1 June 2019 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
JMJames McGrath
James McGrath
COCiarraí O'Toole
Ciarraí O'Toole
GBGavin Bennett
Gavin Bennett
MJMary Joyce
Mary Joyce
MBMiriam A. Byrne
Miriam A. Byrne
Ronan MacLoughlinRonan MacLoughlin
Ronan MacLoughlin
Background: Nebulised medical aerosols are designed to deliver drugs to the lungs to aid in the treatment of respiratory diseases. However, an unintended consequence is the potential for fugitive emissions during patient treatment, which may pose a risk factor in both clinical and homecare settings. Methods: The current study examined the potential for fugitive emissions, using albuterol sulphate as a tracer aerosol during high-flow therapy. A nasal cannula was connected to a head model or alternatively, a interface was connected to a tracheostomy tube in combination with a simulated adult and paediatric breathing profile. Two aerodynamic particle sizers (APS) recorded time-series aerosol concentrations and size distributions at two different distances relative to the simulated patient. Results: The results showed that the quantity and characteristics of the fugitive emissions were influenced by the interface type, patient type and supplemental gas-flow rate. There was a trend in the adult scenarios; as the flow rate increased, the fugitive emissions and the mass median aerodynamic diameter (MMAD) of the aerosol both decreased. The fugitive emissions were comparable when using the adult breathing profiles for the nasal cannula and tracheostomy interfaces; however, there was a noticeable distinction between the two interfaces when compared for the paediatric breathing profiles. The highest recorded aerosol concentration was 0.370 ± 0.046 mg m−3 from the tracheostomy interface during simulated paediatric breathing with a gas-flow rate of 20 L/min. The averaged MMAD across all combinations ranged from 1.248 to 1.793 µm by the APS at a distance of 0.8 m away from the patient interface. Conclusions: Overall, the results highlight the potential for secondary inhalation of fugitive emissions released during simulated aerosol treatment with concurrent high-flow therapy. The findings will help in developing policy and best practice for risk mitigation from fugitive emissions.

1 May 2017 in Building and Environment
Verified
Journal Article
Closed access
JMJames McGrath
James McGrath
JSJ.N. Sheahan
J.N. Sheahan
SDSani Dimitroulopoulou
Sani Dimitroulopoulou
MAM.R. Ashmore
M.R. Ashmore
ATA.C. Terry
A.C. Terry
MBM.A. Byrne
M.A. Byrne

2 February 2021 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
MJMary Joyce
Mary Joyce
JMJames McGrath
James McGrath
MEMarc Mac Giolla Eain
Marc Mac Giolla Eain
AOAndrew O’Sullivan
Andrew O’Sullivan
MBMiriam Byrne
Miriam Byrne
Ronan MacLoughlinRonan MacLoughlin
Ronan MacLoughlin
COVID-19 may lead to serious respiratory complications which may necessitate ventilatory support. There is concern surrounding potential release of patient-derived bioaerosol during nebuliser drug refill, which could impact the health of caregivers. Consequently, mesh nebulisers have been recommended by various clinical practice guidelines. Currently, there is a lack of empirical data describing the potential for release of patient-derived bioaerosol during drug refill. This study examined the release of simulated patient-derived bioaerosol, and the effect on positive end expiratory pressure during nebuliser refill during mechanical ventilation of a simulated patient. During jet nebuliser refill, the positive end expiratory pressure decreased from 4.5 to 0 cm H2O. No loss in pressure was noted during vibrating mesh nebuliser refill. A median particle number concentration of 710 particles cm−3 above ambient was detected when refilling the jet nebuliser in comparison to no increase above ambient detected when using the vibrating mesh nebuliser. The jet nebuliser with the endotracheal tube clamped resulted in 60 particles cm−3 above ambient levels. This study confirms that choice of nebuliser impacts both the potential for patient-derived bioaerosol release and the ability to maintain ventilator circuit pressures and validates the recommended use of mesh nebulisers during mechanical ventilation.