Juan Anso

Dr. Juan Anso


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2017 in Acta Oto-Laryngologica
Verified
Journal Article
Closed access
MCMarco Caversaccio
Marco Caversaccio
KGKate Gavaghan
Kate Gavaghan
WWWilhelm Wimmer
Wilhelm Wimmer
TWTom Williamson
Tom Williamson
JAJuan Anso
Juan Anso
SWStefan Weber
Stefan Weber
Conclusion: A system for robotic cochlear implantation (rCI) has been developed and a corresponding surgical workflow has been described. The clinical feasibility was demonstrated through the conduction of a safe and effective rCI procedure. Objectives: To define a clinical workflow for rCI and demonstrate its feasibility, safety, and effectiveness within a clinical setting. Method: A clinical workflow for use of a previously described image guided surgical robot system for rCI was developed. Based on pre-operative images, a safe drilling tunnel targeting the round window was planned and drilled by the robotic system. Intra-operatively the drill path was assessed using imaging and sensor-based data to confirm the proximity of the facial nerve. Electrode array insertion was manually achieved under microscope visualization. Electrode array placement, structure preservation, and the accuracy of the drilling and of the safety mechanisms were assessed on post-operative CT images. Results: Robotic drilling was conducted with an accuracy of 0.2 mm and safety mechanisms predicted proximity of the nerves to within 0.1 mm. The approach resulted in a minimal mastoidectomy and minimal incisions. Manual electrode array insertion was successfully performed through the robotically drilled tunnel. The procedure was performed without complications, and all surrounding structures were preserved.

1 March 2017 in Science Robotics
Verified
Journal Article
Closed access
PDF file
SWStefan Weber
Stefan Weber
KGKate Gavaghan
Kate Gavaghan
WWWilhelm Wimmer
Wilhelm Wimmer
TWTom Williamson
Tom Williamson
NGNicolas Gerber
Nicolas Gerber
MCMarco Caversaccio
Marco Caversaccio
Image-guided robotic surgery, designed for operating on small structures, is demonstrated for robotic cochlear implantation.

2 August 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MCMarco Caversaccio
Marco Caversaccio
WWWilhelm Wimmer
Wilhelm Wimmer
JAJuan Anso
Juan Anso
GMGeorgios Mantokoudis
Georgios Mantokoudis
NGNicolas Gerber
Nicolas Gerber
SWStefan Weber
Stefan Weber
To demonstrate the feasibility of robotic middle ear access in a clinical setting, nine adult patients with severe-to-profound hearing loss indicated for cochlear implantation were included in this clinical trial. A keyhole access tunnel to the tympanic cavity and targeting the round window was planned based on preoperatively acquired computed tomography image data and robotically drilled to the level of the facial recess. Intraoperative imaging was performed to confirm sufficient distance of the drilling trajectory to relevant anatomy. Robotic drilling continued toward the round window. The cochlear access was manually created by the surgeon. Electrode arrays were inserted through the keyhole tunnel under microscopic supervision via a tympanomeatal flap. All patients were successfully implanted with a cochlear implant. In 9 of 9 patients the robotic drilling was planned and performed to the level of the facial recess. In 3 patients, the procedure was reverted to a conventional approach for safety reasons. No change in facial nerve function compared to baseline measurements was observed. Robotic keyhole access for cochlear implantation is feasible. Further improvements to workflow complexity, duration of surgery, and usability including safety assessments are required to enable wider adoption of the procedure.

31 March 2022 in Journal of Neural Engineering
Verified
Journal Article
Open access
JAJuan Anso
Juan Anso
MBMoaad Benjaber
Moaad Benjaber
BPBrandon Parks
Brandon Parks
SPSamuel Parker
Samuel Parker
COCarina Renate Oehrn
Carina Renate Oehrn
TDTimothy Denison
Timothy Denison
Objective. To provide a design analysis and guidance framework for the implementation of concurrent stimulation and sensing during adaptive deep brain stimulation (aDBS) with particular emphasis on artifact mitigations. Approach. We defined a general architecture of feedback-enabled devices, identified key components in the signal chain which might result in unwanted artifacts and proposed methods that might ultimately enable improved aDBS therapies. We gathered data from research subjects chronically-implanted with an investigational aDBS system, Summit RC + S, to characterize and explore artifact mitigations arising from concurrent stimulation and sensing. We then used a prototype investigational implantable device, DyNeuMo, and a bench-setup that accounts for tissue–electrode properties, to confirm our observations and verify mitigations. The strategies to reduce transient stimulation artifacts and improve performance during aDBS were confirmed in a chronic implant using updated configuration settings. Main results. We derived and validated a ‘checklist’ of configuration settings to improve system performance and areas for future device improvement. Key considerations for the configuration include (a) active instead of passive recharge, (b) sense-channel blanking in the amplifier, (c) high-pass filter settings, (d) tissue–electrode impedance mismatch management, (e) time-frequency trade-offs in the classifier, (f) algorithm blanking and transition rate limits. Without proper channel configuration, the aDBS algorithm was susceptible to limit-cycles of oscillating stimulation independent of physiological state. By applying the checklist, we could optimize each block’s performance characteristics within the overall system. With system-level optimization, a ‘fast’ aDBS prototype algorithm was demonstrated to be feasible without reentrant loops, and with noise performance suitable for subcortical brain circuits. Significance. We present a framework to study sources and propose mitigations of artifacts in devices that provide chronic aDBS. This work highlights the trade-offs in performance as novel sensing devices translate to the clinic. Finding the appropriate balance of constraints is imperative for successful translation of aDBS therapies. Clinical trial: Institutional Review Board and Investigational Device Exemption numbers: NCT02649166/IRB201501021 (University of Florida), NCT04043403/IRB52548 (Stanford University), NCT03582891/IRB1824454 (University of California San Francisco). IDE #180 097.

6 September 2023 in Brain Stimulation
Verified
Journal Article
Open access
JSJames J. Sermon
James J. Sermon
MOMaria Olaru
Maria Olaru
JAJuan Anso
Juan Anso
SCStephanie Cernera
Stephanie Cernera
SLSimon Little
Simon Little
BDBenoit Duchet
Benoit Duchet
The exact mechanisms of deep brain stimulation (DBS) are still an active area of investigation, in spite of its clinical successes. This is due in part to the lack of understanding of the effects of stimulation on neuronal rhythms. Entrainment of brain oscillations has been hypothesised as a potential mechanism of neuromodulation. A better understanding of entrainment might further inform existing methods of continuous DBS, and help refine algorithms for adaptive methods. The purpose of this study is to develop and test a theoretical framework to predict entrainment of cortical rhythms to DBS across a wide range of stimulation parameters. We fit a model of interacting neural populations to selected features characterising PD patients' off-stimulation finely-tuned gamma rhythm recorded through electrocorticography. Using the fitted models, we predict basal ganglia DBS parameters that would result in 1:2 entrainment, a special case of sub-harmonic entrainment observed in patients and predicted by theory. We show that the neural circuit models fitted to patient data exhibit 1:2 entrainment when stimulation is provided across a range of stimulation parameters. Furthermore, we verify key features of the region of 1:2 entrainment in the stimulation frequency/amplitude space with follow-up recordings from the same patients, such as the loss of 1:2 entrainment above certain stimulation amplitudes. Our results reveal that continuous, constant frequency DBS in patients may lead to nonlinear patterns of neuronal entrainment across stimulation parameters, and that these responses can be predicted by modelling. Should entrainment prove to be an important mechanism of therapeutic stimulation, our modelling framework may reduce the parameter space that clinicians must consider when programming devices for optimal benefit.

10 September 2015 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
AFArne Feldmann
Arne Feldmann
JAJuan Anso
Juan Anso
BBBrett Bell
Brett Bell
TWTom Williamson
Tom Williamson
KGKate Gavaghan
Kate Gavaghan
PZPhilippe Zysset
Philippe Zysset