Feras Alrowaie

Dr. Feras Alrowaie

Chemical Engineering, Jubail Industrial College, Jubail, Saudi Arabia
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2012 in Control Engineering Practice
Verified
Journal Article
Closed access
Feras AlrowaieFeras Alrowaie
Feras Alrowaie
RGR.B. Gopaluni
R.B. Gopaluni
KKK.E. Kwok
K.E. Kwok

28 July 2017 in AIChE Journal
Verified
Journal Article
Closed access
PDF file
ATAditya Tulsyan
Aditya Tulsyan
Feras AlrowaieFeras Alrowaie
Feras Alrowaie
BGBhushan Gopaluni
Bhushan Gopaluni

1 June 2014
Verified
Conference Paper
Closed access
Feras AlrowaieFeras Alrowaie
Feras Alrowaie
RGR.B. Gopaluni
R.B. Gopaluni
KKK.E. Kwok
K.E. Kwok
The nonlinear stochastic systems pose two important challenges in designing alarms: 1) measurements are not necessarily Gaussian distributed and 2) measurements are correlated - in particular for closed loop systems. We present an algorithm for designing alarms for such systems with unknown and known models. In the case of unknown models our approach is based on Monte Carlo simulations. In the case of known models, it makes use of a probability density function approximation algorithm called particle filtering. The alarm design algorithm is illustrated through two simulation examples. It was shown that the proposed alarm design was effective in detecting the fault even though the measurements were non-Gaussian.

17 July 2026 in Processes
Verified
Journal Article
Open access
PDF file
Feras AlrowaieFeras Alrowaie
Feras Alrowaie
Conventional hazard and operability (HAZOP) studies remain central to process safety management, but their periodic, document-centered implementation and dependence on expert judgment limit their ability to track dynamic operational risk across the full plant lifecycle. This critical literature review, drawing on 113 sources, examines how digital twin (DT) and artificial intelligence (AI) technologies may augment HAZOP practice, advancing an augmentation principle: DT–AI should strengthen expert-led hazard analysis as a decision-support layer, not replace human judgment. The review maps conventional HAZOP limitations to four complementary technology pathways: AI-assisted knowledge capture and deviation reasoning; DT-based hazard monitoring and early warning; hybrid physics–data modeling for predictive safety; and explainable AI for operator trust and regulatory acceptance. Four representative industrial case studies illustrate current practice, and a structured barrier analysis identifies why many pilots stall before reaching sustained deployment. These pathways offer strong potential to improve HAZOP coverage, traceability, operational relevance, and lifecycle learning, but a study-level evidence assessment finds that no reviewed study demonstrates long-term, multi-site validation of an integrated DT–AI–HAZOP system; most implementations remain at conceptual, prototype, or limited pilot levels. Key failure modes, including model drift, sensor faults, large language model hallucination, and automation complacency, are examined alongside a thirteen-item implementation risk register spanning technical, organizational, economic, security, and scalability concerns. The review proposes a phased industrial implementation roadmap, a lifecycle-oriented safety-management framework, and a three-horizon research agenda for advancing toward reliable, validated HAZOP-informed digital twin systems.

20 July 2026 in Catalysts
Verified
Journal Article
Open access
PDF file
Feras AlrowaieFeras Alrowaie
Feras Alrowaie
Catalyst activity loss reduces both the performance and operating flexibility of industrial sulfur dioxide converters, yet its consequences are rarely assessed beyond conversion declines. This work develops an activity-loss vulnerability framework for a four-bed double-contact SO2 converter model evaluated against an industrial fresh-catalyst benchmark and applies it to four prescribed activity scenarios (a=1.0, 0.8, 0.6, 0.4). At the reference inlet-temperature policy, reducing activity from a=1.0 to a=0.4 lowered conversion from 99.758% to 96.812%, increased outlet SO2 slip from 230 to 2960 ppmv, and raised the hotspot from 613.7 to 660.3 °C, exceeding the adopted illustrative limit of 650 °C. Sensitivity, vulnerability, hotspot risk, and feasible-region maps show that the prescribed activity loss progressively shrinks the permissible operating envelope and creates a coupled productivity–emissions–thermal-safety tradeoff. A non-uniform activity profile at the same mean activity as uniform a=0.6 produced a hotspot that was 9.3 °C higher, demonstrating that average activity alone is insufficient for thermal-risk assessment. Finally, a scenario-relative Operating Efficiency Reduction Index (OERI) integrates conversion loss, SO2-slip increase, and thermal-margin loss into an illustrative scenario-screening score. The results show that catalyst activity loss should be assessed as a coupled performance, emissions, and operational-vulnerability problem rather than conversion decline alone.

31 August 2026 in Catalysts
Verified
Journal Article
Open access
PDF file
Feras AlrowaieFeras Alrowaie
Feras Alrowaie
Routine model-based diagnosis of sulfuric acid converters can attribute performance loss to catalyst deactivation, fouling, bypass, or maldistribution before establishing whether routine measurements distinguish these causes. This study develops the Converter Condition Inference Framework (CCIF) for four-bed double-contact SO2 converters, placing a practical identifiability gate before mechanism-specific interpretation. A reported-parameter reaction and energy balance kernel using published feed, kinetics, and physical reaction enthalpy reproduces the industrial benchmark only approximately. An energy balance check indicates that the reported first-bed conversion and temperature require an effective enthalpy of about 1.6 times the physical value under the adopted thermochemical basis. At the reference condition, the uncertainty-scaled local sensitivity matrix has rank 1 for a six-state vector; this result persists across the tested inlet temperature range and rate and heat release perturbations. In the equilibrium-limited reduced model, catalyst activity loss and fouling down to 40% of fresh activity produce no resolvable change in conversion, outlet SO2 slip, or bed temperatures, whereas bypass alters the temperature signature. Even idealized bed-resolved catalyst condition observations raise the rank only to 5. CCIF therefore reports the evidence-supported state class and required measurement upgrades rather than a validated diagnosis. Unit-specific calibration and catalyst-side evidence remain necessary before mechanism-specific maintenance decisions.