Mandeep Kaur

Ms. Mandeep Kaur

MENRVA Research Group, School of Mechatronic Systems Engineering, Simon Fraser University, Surrey, BC V3T 0A3, Canada
+2
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Mandeep KaurMandeep Kaur
Mandeep Kaur
PLPierre Lane
Pierre Lane
Carlo MenonCarlo Menon
Carlo Menon
Endoscopes are used routinely in modern medicine for in-vivo imaging of luminal organs. Technical advances in the micro-electro-mechanical system (MEMS) and optical fields have enabled the further miniaturization of endoscopes, resulting in the ability to image previously inaccessible small-caliber luminal organs, enabling the early detection of lesions and other abnormalities in these tissues. The development of scanning fiber endoscopes supports the fabrication of small cantilever-based imaging devices without compromising the image resolution. The size of an endoscope is highly dependent on the actuation and scanning method used to illuminate the target image area. Different actuation methods used in the design of small-sized cantilever-based endoscopes are reviewed in this paper along with their working principles, advantages and disadvantages, generated scanning patterns, and applications.

29 September 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Mandeep KaurMandeep Kaur
Mandeep Kaur
PLPierre Lane
Pierre Lane
Carlo MenonCarlo Menon
Carlo Menon
The growth and development of optical components and, in particular, the miniaturization of micro-electro-mechanical systems (MEMSs), has motivated and enabled researchers to design smaller and smaller endoscopes. The overarching goal of this work has been to image smaller previously inaccessible luminal organs in real time, at high resolution, in a minimally invasive manner that does not compromise the comfort of the subject, nor introduce additional risk. Thus, an initial diagnosis can be made, or a small precancerous lesion may be detected, in a small-diameter luminal organ that would not have otherwise been possible. Continuous advancement in the field has enabled a wide range of optical scanners. Different scanning techniques, working principles, and the applications of endoscopic scanners are summarized in this review.

1 January 2021 in Optical Fiber Technology
Verified
Journal Article
Open access
Mandeep KaurMandeep Kaur
Mandeep Kaur
GHGeoffrey Hohert
Geoffrey Hohert
PLPierre Lane
Pierre Lane
CMCarlo Menon
Carlo Menon

4 May 2020 in IEEE Sensors Journal
Verified
Journal Article
Open access
Mandeep KaurMandeep Kaur
Mandeep Kaur
MBMalcolm Brown
Malcolm Brown
PLPierre Lane
Pierre Lane
Carlo MenonCarlo Menon
Carlo Menon

30 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Mandeep KaurMandeep Kaur
Mandeep Kaur
Carlo MenonCarlo Menon
Carlo Menon
Optical scanners are used frequently in medical imaging units to examine and diagnose cancers, assist with surgeries, and detect lesions and malignancies. The continuous growth in optics along with the use of optical fibers enables fabrication of imaging devices as small as a few millimeters in diameter. Most forward viewing endoscopic scanners contain an optical fiber acting as cantilever which is vibrated at resonance. In many cases, more than one actuating element is used to vibrate the optical fiber in two directions giving a 2D scan. In this paper, it is proposed to excite the cantilever fiber using a single actuator and scan a 2D region from its vibrating tip. An electrothermal actuator is optimized to provide a bidirectional (horizontal and vertical) displacement to the cantilever fiber placed on it. A periodic current, having a frequency equal to the resonant frequency of cantilever fiber, was passed through the actuator. The continuous expansion and contraction of the actuator enabled the free end of fiber to vibrate in a circle like pattern. A small change in the actuation frequency permitted the scanning of the area inside the circle.

1 March 2019 in Actuators
Verified
Journal Article
Open access
PDF file
AAAydin Aghajanzadeh Ahrabi
Aydin Aghajanzadeh Ahrabi
Mandeep KaurMandeep Kaur
Mandeep Kaur
YLYasong Li
Yasong Li
PLPierre Lane
Pierre Lane
Carlo MenonCarlo Menon
Carlo Menon
Medical professionals increasingly rely on endoscopes to carry out many minimally invasive procedures on patients to safely examine, diagnose, and treat a large variety of conditions. However, their insertion tube diameter dictates which passages of the body they can be inserted into and, consequently, what organs they can access. For inaccessible areas and organs, patients often undergo invasive and risky procedures—diagnostic confirmation of peripheral lung nodules via transthoracic needle biopsy is one example from oncology. Hence, this work sets out to present an optical-fiber scanner for a scanning fiber endoscope design that has an insertion tube diameter of about 0.5 mm, small enough to be inserted into the smallest airways of the lung. To attain this goal, a novel approach based on resonance thermal excitation of a single-mode 0.01-mm-diameter fiber-optic cantilever oscillating at 2–4 kHz is proposed. The small size of the electro-thermal actuator enables miniaturization of the insertion tube. Lateral free-end deflection of the cantilever is used as a benchmark for evaluating performance. Experimental results show that the cantilever can achieve over 0.2 mm of displacement at its free end. The experimental results also support finite element simulation models which can be used for future design iterations of the endoscope.