A large area silicon drift detectors (SDDs) system and its readout electronics have been developed by the SIDDHARTA-2 Collaboration, aiming to perform high-precision light kaonic atoms x-ray spectroscopy for the investigation of the strong interaction in the low-energy QCD regime. To perform these measurements, a linear energy response and a good energy resolution are mandatory requirements for the system, to be preserved along the whole DAQ (analog and digital) chain; such task is made even harder in the experimental environment of particles colliders, where the high background due to ionizing particles and radiation is present. The energy response of the SDDs system has been characterized with the beam-originating background generated during the commissioning phase of the DAΦNE electron–positron collider (INFN-LNF) in early 2020. The data analysis has been optimized to describe the system’s response and the background. The calibration procedure demonstrates that, despite the high and variable background of the collider, the energy response of the system is linear at the level of few eV ( ), with an energy resolution of eV for the Fe K line.
The VIolation of Pauli exclusion principle -2 experiment, or VIP-2 experiment, at the Laboratori Nazionali del Gran Sasso searches for X-rays from copper a
20 June 2022 in Measurement Science and Technology
The current work presents the optimization of large area silicon drift detectors developed by the SIDDHARTA-2 collaboration for high precision x-ray measurements of light exotic atom transitions. Two different radiation sources were employed in the study: an x-ray tube, for investigating the energy resolution and the charge collection efficiency of the device in the range 4000 eV–13 000 eV, and a β−90 Sr radioactive source for measuring the timing response, thus qualifying the charge drift parameters inside the semiconductor. The study reports the spectroscopic response optimization, together with the tuning of the electron dynamics for the given Silicon technology, by adjusting the applied electric field and the working temperature, which allow a good control of the device’s performances for high precision, timed x-ray spectroscopy applications.
Kaonic atoms measure the antikaon-nucleus interaction at almost zero relative energy, allowing one to determine basic low-energy quantum chromodynamics (QCD) quantities, namely, the antikaon-nucleon ( N) scattering lengths. The latter are important for extracting the sigma terms which are built on the symmetry breaking part of the Hamiltonian, thereby providing a measure of chiral and SU(3) symmetries breaking. After discussing the sigma terms and their relations to the kaonic atoms, we describe the most precise measurement in the literature of kaonic hydrogen, performed at LNF-INFN by the SIDDHARTA experiment. Kaonic deuterium is still to be measured, and two experiments are planned. The first, SIDDHARTA-2 at LNF-INFN was installed on DA NE in spring 2019 and will collect data in 2020. The second, E57 at J-PARC, will become operative in 2021.
Novel, large-area silicon drift detectors (SDDs) have been developed to perform precision measurements of kaonic atom X-ray spectroscopy, for the study the N strong interaction in the low-energy regime. These devices have special geometries, field configurations and read-out electronics, resulting in excellent performances in terms of linearity, stability and energy resolution. In this work the SDDs energy response in the energy region between 4000 eV and 12,000 eV is reported, revealing a stable linear response within 1 eV and good energy resolution.