Thomas P. Burg

Prof. Thomas P. Burg


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 January 2018 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
RFRaffaele Faoro
Raffaele Faoro
MBMargherita Bassu
Margherita Bassu
YMYara X. Mejia
Yara X. Mejia
TSTill Stephan
Till Stephan
NDNikunj Dudani
Nikunj Dudani
TBThomas P. Burg
Thomas P. Burg
Cryogenic fluorescent light microscopy of flash-frozen cells stands out by artifact-free fixation and very little photobleaching of the fluorophores used. To attain the highest level of resolution, aberration-free immersion objectives with accurately matched immersion media are required, but both do not exist for imaging below the glass-transition temperature of water. Here, we resolve this challenge by combining a cryoimmersion medium, HFE-7200, which matches the refractive index of room-temperature water, with a technological concept in which the body of the objective and the front lens are not in thermal equilibrium. We implemented this concept by replacing the metallic front-lens mount of a standard bioimaging water immersion objective with an insulating ceramic mount heated around its perimeter. In this way, the objective metal housing can be maintained at room temperature, while creating a thermally shielded cold microenvironment around the sample and front lens. To demonstrate the range of potential applications, we show that our method can provide superior contrast in Escherichia coli and yeast cells expressing fluorescent proteins and resolve submicrometer structures in multicolor immunolabeled human bone osteosarcoma epithelial (U2OS) cells at −140°C. Significance Cryofluorescence imaging is of great interest in biological microscopy because vitrified samples (i.e., frozen without ice crystallization) are free from fixation artifacts, are highly photostable, and allow direct correlation with electron cryomicroscopy. Here, we show a concept for conducting cryo-light microscopy in immersion that provides a twofold to fivefold increase in image brightness and higher resolution than are attainable with air objectives. Spherical aberration at an imaging temperature below the glass transition of water (−135 °C) is corrected by our approach.

29 October 2013 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
MMMario M. Modena
Mario M. Modena
YWYu Wang
Yu Wang
DRDietmar Riedel
Dietmar Riedel
TBThomas P. Burg
Thomas P. Burg
We introduce the use of correlation analysis to extend the dynamic range of suspended micro- and nanochannel resonator (SMR/SNR) mass sensors by over five orders of magnitude. This method can analyze populations of particles flowing through an embedded channel micromechanical resonator, even when the individual particle masses are far below the noise floor. To characterize the method, we measured the mass of polystyrene nanoparticles with 300 zg resolution. As an application, we monitored the time course of insulin amyloid formation from pre-fibrillar aggregates to mature fibrils of 15 MDa average mass. Results were compared with thioflavin-T (ThT) assays and electron microscopy (EM). Mass measurements offer additional information over ThT during the fluorescent inaccessible lag period, and the average fibril dimensions calculated from the mass signal are in good accordance with EM. In the future, we envision that more detailed modeling will allow the computational deconvolution of multicomponent samples, enabling the mass spectrometric characterization of a variety of biomolecular complexes, small organelles, and nanoparticles in solution.

24 October 2017 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
FPFoelke Purr
Foelke Purr
MBM. Bassu
M. Bassu
RLR. D. Lowe
R. D. Lowe
BTB. Thürmann
B. Thürmann
Andreas DietzelAndreas Dietzel
Andreas Dietzel
TBThomas P. Burg
Thomas P. Burg
Measuring small changes in refractive index can provide both sensitive and contactless information on molecule concentration or process conditions for a wide range of applications. However, refractive index measurements are easily perturbed by non-specific background signals, such as temperature changes or non-specific binding. Here, we present an optofluidic device for measuring refractive index with direct background subtraction within a single measurement. The device is comprised of two interdigitated arrays of nanofluidic channels designed to form an optical grating. Optical path differences between the two sets of channels can be measured directly via an intensity ratio within the diffraction pattern that forms when the grating is illuminated by a collimated laser beam. Our results show that no calibration or biasing is required if the unit cell of the grating is designed with an appropriate built-in asymmetry. In proof-of-concept experiments we attained a noise level equivalent to ∼10−5 refractive index units (30 Hz sampling rate, 4 min measurement interval). Furthermore, we show that the accumulation of biomolecules on the surface of the nanochannels can be measured in real-time. Because of its simplicity and robustness, we expect that this inherently differential measurement concept will find many applications in ultra-low volume analytical systems, biosensors, and portable devices.

8 August 2018 in Journal of Microscopy
Verified
Journal Article
Open access
PDF file
MFM. Fuest
M. Fuest
GNG. M. Nocera
G. M. Nocera
MMM. M. Modena
M. M. Modena
DRD. Riedel
D. Riedel
YMY. X. Mejia
Y. X. Mejia
TBThomas P. Burg
Thomas P. Burg
Summary: Correlating live‐cell imaging with electron microscopy is among the most promising approaches to relate dynamic functions of cells or small organisms to their underlying ultrastructure. The time correlation between light and electron micrographs, however, is limited by the sample handling and fixation required for electron microscopy. Current cryofixation methods require a sample transfer step from the light microscope to a dedicated instrument for cryofixation. This transfer step introduces a time lapse of one second or more between live imaging and the fixed state, which is studied by electron microscopy. In this work, we cryofix Caenorhabditis elegans directly within the light microscope field of view, enabling millisecond time‐correlated live imaging and electron microscopy. With our approach, the time‐correlation is limited only by the sample cooling rate. C. elegans was used as a model system to establish compatibility of in situ cryofixation and subsequent transmission electron microscopy (TEM). TEM images of in situ cryofixed C. elegans show that the ultrastructure of the sample was well preserved with this method. We expect that the ability to correlate live imaging and electron microscopy at the millisecond scale will enable new paradigms to study biological processes across length scales based on real‐time selection and arrest of a desired state.Lay Description: Researchers seek to link cellular functions to their smallest structural components. Currently this requires correlation of two imaging techniques, live imaging and electron microscopy. Current correlative methods, however, have limited time resolution due to the sample preparation procedures for electron microscopy. Following live imaging, samples are transferred from the light microscope to a cryofixation, or ultra‐fast freezing, instrument. The biological process progresses until the sample freezes, 1 second or more after the last live image. In this work, samples are cryofixed directly within the light microscope field of view. By eliminating the transfer step, time correlation between light and electron microscopy images of our samples is limited only by the freezing rate to the order of milliseconds rather than seconds.

27 September 2013 in The European Physical Journal E
Verified
Journal Article
Closed access
PDF file
Rohit JainRohit Jain
Rohit Jain
MPM. Petri
M. Petri
SKS. Kirschbaum
S. Kirschbaum
HFH. Feindt
H. Feindt
SSS. Steltenkamp
S. Steltenkamp
STS. Techert
S. Techert

27 May 2018 in Small
Verified
Journal Article
Open access
PDF file
MMMario M. Modena
Mario M. Modena
PHPatrick Hirschle
Patrick Hirschle
SWStefan Wuttke
Stefan Wuttke
TBThomas P. Burg
Thomas P. Burg
The interplay of physical and chemical properties at the nanometer scale provides porous nanoparticles with unique sorption and interaction capabilities. These properties have aroused great interest toward this class of materials for application ranging from chemical and biological sensing to separation and drug delivery. However, so far the preferential uptake of different components of mixed solvents by porous nanoparticles is not measured due to a lack of methods capable of detecting the resulting change in physical properties. Here, a new method, nanomechanical mass correlation spectroscopy, is used to reveal an unexpected dependence of the effective mass density of porous metal–organic framework (MOF) nanoparticles on the chemistry of the solvent system and on the chemical functionalization of the MOF's internal surface. Interestingly, the pore size of the nanoparticles is much too large for the exclusion of small solvent molecules by steric hindrance. The variation of effective density of the nanoparticles with the solvent composition indicates that a complex solvent environment can form within or around the nanoparticles, which may substantially differ from the solvent composition.