Paola Catalfamo Formento

Dr. Paola Catalfamo Formento

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 June 2010 in Sensors
Verified
Journal Article
Open access
PDF file
PFPaola Catalfamo Formento
Paola Catalfamo Formento
SGSalim Ghoussayni
Salim Ghoussayni
DEDavid Ewins
David Ewins
Gyroscopes have been proposed as sensors for ambulatory gait analysis and functional electrical stimulation systems. Accurate determination of the Initial Contact of the foot with the floor (IC) and the final contact or Foot Off (FO) on different terrains is important. This paper describes the evaluation of a gyroscope placed on the shank for determination of IC and FO in subjects walking outdoors on level ground, and up and down an incline. Performance was compared with a reference pressure measurement system. The mean difference between the gyroscope and the reference was less than –25 ms for IC and less than 75 ms for FO for all terrains. Detection success was over 98%. These results provide preliminary evidence supporting the use of the gyroscope for gait event detection on inclines as well as level walking.

1 September 2020 in Gait & Posture
Verified
Journal Article
Closed access
MRMauricio Riveras
Mauricio Riveras
EREmiliano Ravera
Emiliano Ravera
DEDavid Ewins
David Ewins
ASAliah F. Shaheen
Aliah F. Shaheen
PFPaola Catalfamo Formento
Paola Catalfamo Formento

3 February 2020 in Journal of Mechanical Science and Technology
Verified
Journal Article
Closed access
PDF file
MRM. Riveras
M. Riveras
ERE. Ravera
E. Ravera
ASA. F. Shaheen
A. F. Shaheen
DED. Ewins
D. Ewins
PFPaola Catalfamo Formento
Paola Catalfamo Formento

26 July 2024 in Physical Therapy in Sport
Verified
Journal Article
Closed access
MAMaximiliano Ezequiel Arlettaz
Maximiliano Ezequiel Arlettaz
LDLucas Nahuel Dorsch
Lucas Nahuel Dorsch
PFPaola Catalfamo Formento
Paola Catalfamo Formento

30 October 2024 in Journal of Biomechanics
Verified
Journal Article
Closed access
ELEugenia Soledad Muñoz Larrosa
Eugenia Soledad Muñoz Larrosa
MRMauricio Riveras
Mauricio Riveras
MOMatthew Oldfield
Matthew Oldfield
ASAliah F Shaheen
Aliah F Shaheen
GSGaston Schlotthauer
Gaston Schlotthauer
PFPaola Catalfamo Formento
Paola Catalfamo Formento

20 November 2024 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
MRMauricio Riveras
Mauricio Riveras
MOMatthew Oldfield
Matthew Oldfield
PFPaola Catalfamo Formento
Paola Catalfamo Formento
Subjects with unilateral transtibial amputation exhibit altered minimum toe clearance (MTC) depending on the ankle prosthesis used. It has been suggested that a limited prosthetic ankle angle could be the cause of the change. The aim of this study was to investigate the alterations in kinematics in the joints responsible for the changes in MTC when using an articulating hydraulic ankle (AHA) prosthesis compared to a nonarticulating ankle (NAA) prosthesis. Twelve participants with unilateral transtibial amputation walked at their self-selected speed on a 10 m pathway. They used both the same AHA and NAA prosthetic models and the prosthetic characteristics were unchanged except for the ankle mechanisms and, consequently, its mass. Data from MTC and hip, knee, and ankle angles in the sagittal, frontal, and transversal plane at the time of MTC were statistically analyzed with a paired sample t-test. The AHA prosthesis showed significantly higher MTC mean (AHA=24.7 ± 9.6 mm versus NAA=17.4 ± 5.2 mm, P<0.01) and variability (13.4 ± 9.6 mm versus 6.7 ± 4.2 mm, P=0.03) on the prosthetic limb than the NAA. A higher mean MTC could be explained by an increase in ankle angle dorsiflexion (AHA=−1.2 ± 2.6 deg versus NAA=−2.9 ± 1.5 deg, P=0.01), while the variability of the prosthetic MTC appears to be influenced by changes in prosthetic mass. The results of this study suggest that ankle dorsiflexion during swing and the mass of the prosthesis have a direct influence in mean MTC and its variability, respectively.