Wei Wei

Wei Wei

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2019 in Fuel
Verified
Journal Article
Closed access
YWYu Wang
Yu Wang
YDYiming Ding
Yiming Ding
WWWei Wei
Wei Wei
YCYi Cao
Yi Cao
DDDavid F. Davidson
David F. Davidson
RHRonald K. Hanson
Ronald K. Hanson

1 April 2019 in Fuel
Verified
Journal Article
Closed access
YWYu Wang
Yu Wang
YCYi Cao
Yi Cao
WWWei Wei
Wei Wei
DDDavid F. Davidson
David F. Davidson
RHRonald K. Hanson
Ronald K. Hanson

1 October 2013 in Optics Communications
Verified
Journal Article
Closed access
BSB.N. Sun
B.N. Sun
JCJ. Chang
J. Chang
JLJ. Lian
J. Lian
ZWZ.L. Wang
Z.L. Wang
GLG.P. Lv
G.P. Lv
SZS.S. Zhang
S.S. Zhang

1 June 2017 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
FWFupeng Wang
Fupeng Wang
JCJun Chang
Jun Chang
Qiang WangQiang Wang
Qiang Wang
WWWei Wei
Wei Wei
ZQZengguang Qin
Zengguang Qin

12 December 2018 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
WWWei Wei
Wei Wei
WPWen Yu Peng
Wen Yu Peng
YWYu Wang
Yu Wang
RCRishav Choudhary
Rishav Choudhary
SWShengkai Wang
Shengkai Wang
RHRonald K. Hanson
Ronald K. Hanson

27 October 2016 in Photonic Sensors
Verified
Journal Article
Open access
PDF file
XCXi Chen
Xi Chen
JCJun Chang
Jun Chang
FWFupeng Wang
Fupeng Wang
ZWZongliang Wang
Zongliang Wang
WWWei Wei
Wei Wei
ZQZengguang Qin
Zengguang Qin
A portable analog lock-in amplifier capable of accurate phase detection is proposed in this paper. The proposed lock-in amplifier, which uses the dual-channel orthometric signals as the references to build the xy coordinate system, can detect the relative phase between the input and x-axis based on trigonometric function. The sensitivity of the phase measurement reaches 0.014 degree, and a detection precision of 0.1 degree is achieved. At the same time, the performance of the lock-in amplifier is verified in the high precision optical oxygen concentration detection. Experimental results reveal that the portable analog lock-in amplifier is accurate for phase detection applications. In the oxygen sensing experiments, 0.058% oxygen concentration resulted in 0.1 degree phase shift detected by the lock-in amplifier precisely. In addition, the lock-in amplifier is small and economical compared with the commercial lock-in equipments, so it can be easily integrated in many portable devices for industrial applications.