Xiaofeng Chang

Xiaofeng Chang


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 June 2019 in Cells
Verified
Journal Article
Open access
PDF file
JLJin Liu
Jin Liu
JRJianping Ruan
Jianping Ruan
Michael WeirMichael Weir
Michael Weir
KRKe Ren
Ke Ren
Abraham SchneiderAbraham Schneider
Abraham Schneider
HXHockin Xu
Hockin Xu
Periodontitis is a prevalent infectious disease worldwide, causing the damage of periodontal support tissues, which can eventually lead to tooth loss. The goal of periodontal treatment is to control the infections and reconstruct the structure and function of periodontal tissues including cementum, periodontal ligament (PDL) fibers, and bone. The regeneration of these three types of tissues, including the re-formation of the oriented PDL fibers to be attached firmly to the new cementum and alveolar bone, remains a major challenge. This article represents the first systematic review on the cutting-edge researches on the regeneration of all three types of periodontal tissues and the simultaneous regeneration of the entire bone-PDL-cementum complex, via stem cells, bio-printing, gene therapy, and layered bio-mimetic technologies. This article primarily includes bone regeneration; PDL regeneration; cementum regeneration; endogenous cell-homing and host-mobilized stem cells; 3D bio-printing and generation of the oriented PDL fibers; gene therapy-based approaches for periodontal regeneration; regenerating the bone-PDL-cementum complex via layered materials and cells. These novel developments in stem cell technology and bioactive and bio-mimetic scaffolds are highly promising to substantially enhance the periodontal regeneration including both hard and soft tissues, with applicability to other therapies in the oral and maxillofacial region.

1 September 2017 in Dental Materials
Verified
Journal Article
Closed access
MWMichael D. Weir
Michael D. Weir
JRJianping Ruan
Jianping Ruan
NZNing Zhang
Ning Zhang
LCLaurence C. Chow
Laurence C. Chow
KZKe Zhang
Ke Zhang
HXHockin H.K. Xu
Hockin H.K. Xu

14 May 2024 in Head & Face Medicine
Verified
Journal Article
Open access
PDF file
HYHamza Younis
Hamza Younis
CLChengpeng Lv
Chengpeng Lv
BXBoya Xu
Boya Xu
HZHuixia Zhou
Huixia Zhou
LDLiangzhi Du
Liangzhi Du
LHLonglong He
Longlong He
Background: Computer-guided implant surgery has improved the quality of implant treatment by facilitating the placement of implants in a more accurate manner. This study aimed to assess the accuracy of implant placement in a clinical setting using three techniques: dynamic navigation, static surgical guides, and freehand placement. We also investigated potential factors influencing accuracy to provide a comprehensive evaluation of each technique’s advantages and disadvantages. Materials and methods: Ninety-four implants in 65 patients were included in this prospective study. Patients were randomly assigned to one of three groups: dynamic navigation, static surgical guides, or freehand placement. Implants were placed using a prosthetically oriented digital implant planning approach, and postoperative CBCT scans were superimposed on preoperative plans to measure accuracy. Seven deviation values were calculated, including angular, platform, and apical deviations. Demographic and consistency analyses were performed, along with one-way ANOVA and post-hoc tests for deviation values. Results: The mean global platform, global apical, and angular deviations were 0.99 mm (SD 0.52), 1.14 mm (SD 0.56), and 3.66° (SD 1.64°) for the dynamic navigation group; 0.92 mm (SD 0.36), 1.06 mm (SD 0.47), and 2.52° (SD 1.18°) for the surgical guide group; and 1.36 mm (SD 0.62), 1.73 mm (SD 0.66), and 5.82° (SD 2.79°) for the freehand group. Both the dynamic navigation and surgical guide groups exhibited statistically significant differences in all values except depth deviations compared to the freehand group (p < 0.05), whereas only the angular deviation showed a significant difference between the dynamic navigation and surgical guide groups (p = 0.002). Conclusion: Our findings highlight the superior accuracy and consistency of dynamic navigation and static surgical guides compared to freehand placement in implant surgery. Dynamic navigation offers precision and flexibility. However, it comes with cost and convenience considerations. Future research should focus on improving its practicality. Trial Registration: This study was retrospectively registered at the Thai Clinical Trials Register-Medical Research Foundation of Thailand (MRF) with the TCTR identification number TCTR20230804001 on 04/08/2023. It was also conducted in accordance with the Declaration of Helsinki and approved by the institutional ethics committee at the Xian Jiaotong University Hospital of Stomatology, Xian, China (xjkqII[2021] No: 043). Written informed consent was obtained from all participants.

1 September 2018 in Dental Materials
Verified
Journal Article
Closed access
YLYuncong Li
Yuncong Li
XHXiaoyi Hu
Xiaoyi Hu
YXYang Xia
Yang Xia
YJYadong Ji
Yadong Ji
JRJianping Ruan
Jianping Ruan
HXHockin Xu
Hockin Xu

1 July 2019 in Dental Materials
Verified
Journal Article
Closed access
YLYing Lin
Ying Lin
SHShuheng Huang
Shuheng Huang
RZRui Zou
Rui Zou
XGXianling Gao
Xianling Gao
JRJianping Ruan
Jianping Ruan
HXHockin Xu
Hockin Xu

1 August 2019 in Dental Materials
Verified
Journal Article
Closed access
JWJunling Wu
Junling Wu
CZChuanjian Zhou
Chuanjian Zhou
JRJianping Ruan
Jianping Ruan
MWMichael D. Weir
Michael D. Weir
FTFranklin Tay
Franklin Tay
HXHockin Xu
Hockin Xu