This paper presents a research focused on embroidered temperature and humidity sensor elements for smart textile applications in health and medical care. Smart textile products face desirable textile properties for health care use include durability, “launderability” (washing resistance), flexibility and non-toxicity and the comfort aspect of clothing is also very important. For these reasons, the presented research was concentrated on the development of sensor elements based on specially prepared conductive yarns which are integrated into textile fabric with the familiar textile technique - embroidery and connected to control unit through snap fasteners. All the sensor element manufacturing steps are fully compatible with textile processing techniques. The preliminary investigation into the design, manufacturing and testing of the textile based temperature and humidity sensor elements are described in the paper.
The presented study is focused on the improvements of static and dynamic characteristics of organic electrochemical transistor (OECT). Especially the switching speed, the switching ratio and stability were examined. For the given study a special structure of the OECT has been developed for the evaluation of various materials and their influence on selected characteristics. Conductive polymer poly(3,4-ethylene dioxythiophene)-poly(styrene sulfonate) (PEDOT:PSS) was used as the main material for channel of OECT device. The influence of two ionic liquids (ILs) used as an electrolyte in OECT is compared. The results indicate a significant difference between ILs and their suitability to be used as electrolyte in the OECT.
30 September 2016 in Periodica Polytechnica Electrical Engineering and Computer Science
The study is focused on a comparison of quasi-solid and liquid electrolytes for organic electrochemical transistor (OECT). Especially influences of used electrolytes on the switching speed and the switching ratio were compared. For the given study a three electrode structure of the OECT has been used for the evaluation of various materials and their influence on selected characteristics. For the channel of the OECT device, conductive polymer poly(3,4-ethylenedioxythiophene) poly(styrene sulfonate) (PEDOT.PSS) was used. Two different ionic liquids and one quasi-solid state electrolyte were used and compared in OECT structure. The results show that both OECTs with ionic liquids are faster than the OECT with quasi-solid state electrolyte but have approximately 10 times smaller switching ratio.
The paper is focused on the study of electric and temperature properties of electrochemical transistor based on ionic liquid, 1-ethyl-3-methylimidazolium ethyl sulfate. The transistor shows good output source-drain character- istics. The switching characteristics are as follows: The current switching is from –1.1×10−4 A to –1.5 ×10−7A, i.e., the switching ratio is about 700. The current kinetics can be described by stretched exponential function. The current-temperature dependence follows well the Arrhenius equation. Activation energy of the source-drain current is 0.1 eV in the closed state and 0.02 eV in the open state. Both activation energies are voltage independent.
The paper deals with the description of the measuring method of temperature modulated electric current and influence of electric field on current in organic electrochemical transistors (OECT). The results of temperature dependences of current-voltage characteristics and their interpretation are presented. The measurements were performed on the organic electrochemical transistors with 3 ionic liquids: a) 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imid (No1), b) 1-ethyl-3-methylimidazolium ethyl sulfate (No4) and c) 1-ethyl-3-methylimidazolium tetrafluoroborate (No9). The method enables to measure the voltage and temperature dependence of the current in one step. Thus, the measured current response is influenced not only by temperature change but also by relaxation processes at the same time. The result is the dependence of activation energy on the source-drain voltage.