Jalil Shaeri

Jalil Shaeri

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2019 in Environments
Verified
Journal Article
Open access
PDF file
JSJalil Shaeri
Jalil Shaeri
AHAmin Habibi
Amin Habibi
MYMahmood Yaghoubi
Mahmood Yaghoubi
Ata ChokhachianAta Chokhachian
Ata Chokhachian
About half of the energy loss in buildings is wasted through windows. Determining the optimum window-to-wall ratio (WWR) for different building facades would reduce such energy losses. The optimum WWR is the window area that minimizes the total annual energy of cooling, heating, and lighting. The purpose of this study is to investigate the optimum WWR of different facades of an office building. For this purpose, a sample building is simulated by means of DesignBuilder software in order to investigate the annual solar heat gain, cooling load, heating load, and lighting consumption for the three cities of Bushehr, Shiraz, and Tabriz, and optimum window areas of office buildings for the three cities are determined. Based on the results, the optimum window area for the north building facade for all climates is 20–30%. This amount for the southern facade of the building in Bushehr, Shiraz, and Tabriz is, respectively, 20–30%, 10–30%, and 20–50%. The optimum window area for the eastern and western building facades in Bushehr is 30–50%; in Tabriz it is 40–70%, and in Shiraz it is 20–60% and 40–70%, respectively. The difference between the maximum and minimum energy consumption with different window areas in Bushehr and Shiraz is 20–100% and in Tabriz it is 16–25%.

9 September 2018 in Buildings
Verified
Journal Article
Open access
PDF file
JSJalil Shaeri
Jalil Shaeri
MYMahmood Yaghoubi
Mahmood Yaghoubi
AAArdalan Aflaki
Ardalan Aflaki
AHAmin Habibi
Amin Habibi
A considerable amount of energy is being consumed for heating and cooling indoor environments in order to provide thermal comfort. For older buildings located in the southern parts of Iran, particularly in Bushehr, many climatic and passive design strategies are being used to provide indoor thermal comfort. This architecture and these elements have been developed in response to unfavorable weather conditions. The current study aimed to identify those passive elements and evaluate indoor thermal comfort in older houses. To achieve these objectives, passive elements in main houses located in the ancient urban structure were first identified. Then, a house in the coastal belt, Tabib’s house, and another house inside the ancient urban structure, Nozari’s house, were selected for the purpose of field measurement. The results revealed that the passive techniques used in these older houses significantly provide sufficient indoor thermal conditions. The mean measured predicted mean vote (PMV) of Tabib’s rooms was 0.88 and the mean measured PMV of Nozari’s rooms was 0.91, which were in an acceptable range. The measured predicted percentage of dissatisfied of rooms in both houses were lower than 10%. The main factor in creating indoor thermal comfort in these houses was the natural ventilation and its availability in the selected houses.

17 April 2023 in Energy
Verified
Journal Article
Closed access
AGAli Goharian
Ali Goharian
KDKhosro Daneshjoo
Khosro Daneshjoo
JSJalil Shaeri
Jalil Shaeri
MMMohammadjavad Mahdavinejad
Mohammadjavad Mahdavinejad
MYMansour Yeganeh
Mansour Yeganeh

22 August 2022 in Journal of Building Engineering
Verified
Journal Article
Closed access
JSJalil Shaeri
Jalil Shaeri
Mohammadjavad MahdavinejadMohammadjavad Mahdavinejad
Mohammadjavad Mahdavinejad
MPMohammad Hossein Pourghasemian
Mohammad Hossein Pourghasemian

9 January 2019 in Sustainability
Verified
Journal Article
Open access
PDF file
JSJalil Shaeri
Jalil Shaeri
MYMahmood Yaghoubi
Mahmood Yaghoubi
AHAmin Habibi
Amin Habibi
Ata ChokhachianAta Chokhachian
Ata Chokhachian
Extensive cost in the building industry comes from cooling and heating to create thermal comfort. Hence, it is necessary to utilize passive solutions, in addition to suitable design, in order to reduce energy consumption. This research attempts to investigate the impact of archetype patterns in office buildings on annual energy consumption for cooling, heating and daylight loads. For this purpose, the DesignBuilder software was used to compare the forms. In this study, four conventional construction forms were considered, including the single and dense form, central courtyard buildings, U form and linear form, and each was considered with two, four and six-stories. Forms were simulated in the three cities of Bushehr, Shiraz and Tabriz, with hot-humid, hot-dry and cold climates, respectively. The results revealed that the office building with a linear form in Bushehr had the lowest energy consumption in the two and four-story forms, and also in the six-story form, the central courtyard form had the lowest energy consumption. Additionally, the central courtyard forms in Tabriz and Shiraz had the lowest energy consumption in all cases. Finally, the linear form possessed the most natural daylight through all of the studied cases for the three cities in terms of natural light gain.

10 July 2022 in International Journal of Ambient Energy
Verified
Journal Article
Closed access
JSJalil Shaeri
Jalil Shaeri
Mohammadjavad MahdavinejadMohammadjavad Mahdavinejad
Mohammadjavad Mahdavinejad
In the current study, the passive strategies in traditional houses of Shiraz were investigated and correlation between PMV/PPD model and environmental parameters have been evaluated topredict thermal comfort in traditional houses. In this study, firstly a traditional house as a case study was selected and the thermal comfort conditions of the talar room were analyzed with the PMV/PPD model by DesignBuilder software. Results revealed that PMV of talar room in May, June, September, and October were in the range of -1 and 1 which shows thermal comfort condition has been convenient. Additionally, PMV possessed the highest correlation coefficients with Ta (r = 0.84), Tr (r = 0.84), Top (r = 0.84), Tout (r = 0.82) and lowest correlation coefficients with RH (r = 0.69). It has been discovered that PMV is more similar to PPD (r = 0.95).