Isabella Marchesi

Isabella Marchesi

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
SPStefania Paduano
Stefania Paduano
AGAntonella Greco
Antonella Greco
LBLucia Borsari
Lucia Borsari
CSChiara Salvia
Chiara Salvia
STStefano Tancredi
Stefano Tancredi
IMIsabella Marchesi
Isabella Marchesi
Children obesity is a serious public health issue. This study aimed to investigate physical/sedentary activities of first-year primary schools children in Modena, and their association with overweight/obesity and dietary habits of children and family characteristics to identify the risk factors for unhealthy lifestyles. Child physical/sedentary activities were gathered through an anonymous questionnaire administered to parents, as well as family characteristics and weight/height of child and parents. Logistic regression models, eventually adjusted for parents’ sociodemographic characteristics, were used to analyze data. Questionnaires were delivered by 660 families (74.2%), of which 72 without anthropometric data were excluded. Three out of four children spent in physical activities less than 7 h/week, while 63.9% dedicated to sedentary activities two or more hours/day. From multivariate analysis, the habit significantly affecting children’s overweight/obesity was spending time on tablets/Personal Computers/mobile phones/videogames. Higher parental education level resulted in a protective factor for implementing unhealthy lifestyles in terms of time dedicated to physical/sedentary activities. Our results suggest the need of interventions to increase time for physical activity and to promote a responsible use of digital media involving the entire families to reach all parents regardless of their education and nationality with a possible relapse on other family members.

15 May 2016 in Applied and Environmental Microbiology
Verified
Journal Article
Open access
PDF file
IMIsabella Marchesi
Isabella Marchesi
GFGreta Ferranti
Greta Ferranti
AMAntonella Mansi
Antonella Mansi
AMAnna M. Marcelloni
Anna M. Marcelloni
APAnna R. Proietto
Anna R. Proietto
Annalisa BARGELLINIAnnalisa BARGELLINI
Annalisa BARGELLINI
Physical and chemical disinfection methods have been proposed with the aim of controlling Legionella water contamination. To date, the most effective procedures for reducing bacterial contamination have not yet been defined. The aim of this study was to assess the long-term effectiveness of various disinfection procedures in order to reduce both culturable and nonculturable (NC) legionellae in different hospital water networks treated with heat, chlorine dioxide, monochloramine, and hydrogen peroxide. The temperature levels and biocide concentrations that proved to give reliable results were analyzed. In order to study the possible effects on the water pipes, we verified the extent of corrosion on experimental coupons after applying each method for 6 months. The percentage of positive points was at its lowest after treatment with monochloramine, followed by chlorine dioxide, hydrogen peroxide, and hyperthermia. Different selections of Legionella spp. were observed, as networks treated with chlorine-based disinfectants were contaminated mainly by Legionella pneumophila serogroup 1, hyperthermia was associated with serogroups 2 to 14, and hydrogen peroxide treatment was associated mainly with non- pneumophila species. NC cells were detected only in heat-treated waters, and also when the temperature was approximately 60°C. The corrosion rates of the coupons were within a satisfactory limit for water networks, but the morphologies differed. We confirm here that chemical disinfection controls Legionella colonization more effectively than hyperthermia does. Monochloramine was the most effective treatment, while hydrogen peroxide may be a promising alternative to chlorine-based disinfectants due to its ability to select for other, less virulent or nonpathogenic species.

IMIsabella Marchesi
Isabella Marchesi
SPStefania Paduano
Stefania Paduano
GFGiuseppina Frezza
Giuseppina Frezza
LSLuca Sircana
Luca Sircana
EVElena Vecchi
Elena Vecchi
Annalisa BARGELLINIAnnalisa BARGELLINI
Annalisa BARGELLINI
The formation of potentially carcinogenic N-nitrosamines, associated with monochloramine, requires further research due to the growing interest in using this biocide for the secondary disinfection of water in public and private buildings. The aim of our study was to evaluate the possible formation of N-nitrosamines and other toxic disinfection by-products (DBPs) in hospital hot water networks treated with monochloramine. The effectiveness of this biocide in controlling Legionella spp. contamination was also verified. For this purpose, four different monochloramine-treated networks, in terms of the duration of treatment and method of biocide injection, were investigated. Untreated hot water, municipal cold water and, limited to N-nitrosamines analysis, hot water treated with chlorine dioxide were analyzed for comparison. Legionella spp. contamination was successfully controlled without any formation of N-nitrosamines. No nitrification or formation of the regulated DBPs, such as chlorites and trihalomethanes, occurred in monochloramine-treated water networks. However, a stable formulation of hypochlorite, its frequent replacement with a fresh product, and the routine monitoring of free ammonia are recommended to ensure a proper disinfection. Our study confirms that monochloramine may be proposed as an effective and safe strategy for the continuous disinfection of building plumbing systems, preventing vulnerable individuals from being exposed to legionellae and dangerous DBPs.

28 December 2016 in Environmental Science and Pollution Research
Verified
Journal Article
Closed access
PDF file
Annalisa BARGELLINIAnnalisa BARGELLINI
Annalisa BARGELLINI
FVFrancesco Venturelli
Francesco Venturelli
ECElisabetta Casali
Elisabetta Casali
AFAngela Ferrari
Angela Ferrari
IMIsabella Marchesi
Isabella Marchesi
PBPaola Borella
Paola Borella

25 October 2017 in Water Supply
Verified
Journal Article
Closed access
PDF file
SPStefania Paduano
Stefania Paduano
FVFederica Valeriani
Federica Valeriani
Vincenzo Romano SpicaVincenzo Romano Spica
Vincenzo Romano Spica
Annalisa BARGELLINIAnnalisa BARGELLINI
Annalisa BARGELLINI
PBPaola Borella
Paola Borella
IMIsabella Marchesi
Isabella Marchesi
In literature, the microbial diversity of hot spring waters has been the focus of extensive research, while there is a paucity of studies on thermal water distribution network of spa centres and as yet no studies have been carried out on the bacterial population of thermal muds. In this context, the aim of our study is to characterize the microbial community of sulphurous-bromine-iodine thermal water and mud within an Italian spa complex using Next Generation Sequencing (NGS) technologies. This is the first report of microbiome characterization along a water supply network from the spring to points of use within a spa. According to the 16S rRNA gene sequences analysis, our data highlight the presence of a typical microbial community, mainly composed of sulphur-cycling bacteria belonging to Desulfomonile, Thermodesulfovibrio, Geothermobacterium, Thermus, Thiofaba and Syntrophomonas genera. In addition, the characterization and evolution of the bacterial community in thermal muds during the maturation process is investigated for the first time. Interestingly, the microbiome of mature mud resulted dominated by bacteria capable of lipid biosynthesis, suggesting that these bacteria may play a role in the anti-rheumatic properties of thermal mud.

2 September 2013 in Journal of Water and Health
Verified
Journal Article
Closed access
PDF file
IMIsabella Marchesi
Isabella Marchesi
GFGreta Ferranti
Greta Ferranti
Annalisa BARGELLINIAnnalisa BARGELLINI
Annalisa BARGELLINI
PMPatrizia Marchegiano
Patrizia Marchegiano
GPGuerrino Predieri
Guerrino Predieri
PBPaola Borella
Paola Borella
Legionella colonization in hospital hot water distribution networks was evaluated following 36 months of continuous treatment with monochloramine and compared with chlorine dioxide. Nitrite, nitrate, chlorite, chlorate, bromide, trihalomethanes and haloacetic acids as well as the biocide concentration at sampled points were measured. Only 8/84 samples treated with monochloramine were found contaminated and after the first 8 months of treatment no Legionella was isolated. Chlorine dioxide was associated with a strong reduction in Legionella contamination compared to pre-treatment, but differences according to the device were observed. Monochloramine between 2 and 3 mg l−1 and chlorine dioxide between 0.50 and 0.70 mg l−1 were needed to control Legionella colonization. Comparing no- and post-flush samples, a higher frequency of no-flush positive samples was noted using chlorine dioxide, suggesting an increased risk for patients when they open the tap. No increase in chlorite levels and no water nitrification occurred by using monochloramine. Chlorite at levels exceeding the limit requested for drinking water was measured when chlorine dioxide was applied. In conclusion, we highlight that continuous injection of monochloramine should be considered as an effective alternative to chlorine dioxide in controlling legionellae contamination inside hospital water distribution systems.