Giovanni Bolelli

Prof. Giovanni Bolelli

Department of Engineering "Enzo Ferrari", University of Modena and Reggio Emilia, Via P. Vivarelli 10/1, I-41125 Modena (MO), Italy
orcid

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2006 in Wear
Verified
Journal Article
Closed access
Giovanni BolelliGiovanni Bolelli
Giovanni Bolelli
Valeria CannilloValeria Cannillo
Valeria Cannillo
Luca LusvarghiLuca Lusvarghi
Luca Lusvarghi
TMTiziano Manfredini
Tiziano Manfredini

1 January 2014 in Wear
Verified
Journal Article
Closed access
Giovanni BolelliGiovanni Bolelli
Giovanni Bolelli
LBLutz-Michael Berger
Lutz-Michael Berger
MBMatteo Bonetti
Matteo Bonetti
Luca LusvarghiLuca Lusvarghi
Luca Lusvarghi

1 March 2015 in Surface and Coatings Technology
Verified
Journal Article
Open access
Giovanni BolelliGiovanni Bolelli
Giovanni Bolelli
LBLutz-Michael Berger
Lutz-Michael Berger
TBT. Börner
T. Börner
Heli KoivuluotoHeli Koivuluoto
Heli Koivuluoto
Luca LusvarghiLuca Lusvarghi
Luca Lusvarghi
Petri VuoristoPetri Vuoristo
Petri Vuoristo
This paper provides a comprehensive assessment of the sliding and abrasive wear behaviour of WC-10Co4Cr hardmetal coatings, representative of the existing state-of-the-art. A commercial feedstock powder with two different particle size distributions was sprayed onto carbon steel substrates using two HVOF and two HVAF spray processes. Mild wear rates of <10-7mm3/(Nm) and friction coefficients of ≈0.5 were obtained for all samples in ball-on-disk sliding wear tests at room temperature against Al2O3 counterparts. WC-10Co4Cr coatings definitely outperform a reference electrolytic hard chromium coating under these test conditions. Their wear mechanisms include extrusion and removal of the binder matrix, with the formation of a wavy surface morphology, and brittle cracking. The balance of such phenomena is closely related to intra-lamellar features, and rather independent of those properties (e.g. indentation fracture toughness, elastic modulus) which mainly reflect large-scale inter-lamellar cohesion, as quantitatively confirmed by a principal component analysis. Intra-lamellar dissolution of WC into the matrix indeed increases the incidence of brittle cracking, resulting in slightly higher wear rates. At 400°C, some of the hardmetal coatings fail because of the superposition between tensile residual stresses and thermal expansion mismatch stresses (due to the difference between the thermal expansion coefficients of the steel substrate and of the hardmetal coating). Those which do not fail, on account of lower residual stresses, exhibit higher wear rates than at room temperature, due to oxidation of the WC grains.The resistance of the coatings against abrasive wear, assessed by dry sand-rubber wheel testing, is related to inter-lamellar cohesion, as proven by a principal component analysis of the collected dataset. Therefore, coatings deposited from coarse feedstock powders suffer higher wear loss than those obtained from fine powders, as brittle inter-lamellar detachment is caused by their weaker interparticle cohesion, witnessed by their systematically lower fracture toughness as well

1 July 2016 in Wear
Verified
Journal Article
Open access
Giovanni BolelliGiovanni Bolelli
Giovanni Bolelli
LBLutz-Michael Berger
Lutz-Michael Berger
TBT. Börner
T. Börner
Heli KoivuluotoHeli Koivuluoto
Heli Koivuluoto
VMVille Matikainen
Ville Matikainen
Petri VuoristoPetri Vuoristo
Petri Vuoristo
This paper provides a comprehensive characterisation of HVOF- and HVAF-sprayed Cr3C2-25 wt.% NiCr hardmetal coatings. One commercial powder composition with two different particle size distributions was processed using five HVOF and HVAF thermal spray systems. All coatings contain less Cr3C2 than the feedstock powder, possibly due to the rebound of some Cr3C2-rich particles during high-velocity impact onto the substrate. Dry sand-rubber wheel abrasive wear testing causes both grooving and pull-out of splat fragments. Mass losses depend on inter- and intra-lamellar cohesion, being higher (≥70 mg after a wear distance of 5904 m) for the coatings deposited with the coarser feedstock powder or with one type of HVAF torch. Sliding wear at room temperature against alumina involves shallower abrasive grooving, small-scale delamination and carbide pull-outs, and it is controlled by intra-lamellar cohesion. The coatings obtained from the fine feedstock powder exhibit the lowest wear rates (≈5×10-6 mm3/(Nm)). At 400 °C, abrasive grooving dominates the sliding wear behaviour; wear rates increase by one order of magnitude but friction coefficients decrease from ≈0.7 to ≈0.5. The thermal expansion coefficient of the coatings (11.08×10-6 °C-1 in the 30-400 °C range) is sufficiently close to that of the steel substrate (14.23×10-6 °C-1) to avoid macro-cracking

1 October 2017 in Wear
Verified
Journal Article
Closed access
VMVille Matikainen
Ville Matikainen
Giovanni BolelliGiovanni Bolelli
Giovanni Bolelli
Heli KoivuluotoHeli Koivuluoto
Heli Koivuluoto
PSP. Sassatelli
P. Sassatelli
Luca LusvarghiLuca Lusvarghi
Luca Lusvarghi
Petri VuoristoPetri Vuoristo
Petri Vuoristo

1 February 2012 in Wear
Verified
Journal Article
Closed access
Giovanni BolelliGiovanni Bolelli
Giovanni Bolelli
BBBenedetta Bonferroni
Benedetta Bonferroni
JLJussi Laurila
Jussi Laurila
Luca LusvarghiLuca Lusvarghi
Luca Lusvarghi
AMAndrea Milanti
Andrea Milanti
Petri VuoristoPetri Vuoristo
Petri Vuoristo