Objective. The purpose of this study was to compare the color changes and microhardness of a nanocomposite after four bleaching regimens.Materials. Twenty-five specimenswere made with a nanocomposite resin (Filtek Supreme XT). The specimens were divided into five groups equally: bleaching groups and control group, as follows: G1: artificial saliva atC; (control) G2: hydrogen peroxide (HP) at 7%; G3: hydrogen peroxide (HP) at 35%; G4: carbamide peroxide (CP) at 10%; G5: carbamide peroxide (CP) 35%. Color measurements were made with spectrophotometer using CIELAB color scale. The Vickers hardness (VHN) measurements were performed at the top surface. The data were analyzed with two-way Analysis of Variance.Results.E and VHN mean values into the groups were not statistically different, however, the VHN mean values before and after storage and bleaching showed statistically significant differences.Conclusion. Nanocomposite samples showed no significant alteration (color and microhardness) after bleaching. Thus, no replacement of restorations is required after bleaching.
The different parameters used for the photoactivation process provide changes in the degree of conversion (DC%) and temperature rise (TR) of the composite resins. Thus, the purpose of this study was to evaluate the DC (%) and TR of the microhybrid composite resin photoactivated by a new generation LED. For the KBr pellet technique, the composite resin was placed into a metallic mould (1-mm thickness and 4-mm diameter) and photoactivated as follows: continuous LED LCU with different power density values (50–1000 mW/cm2). The measurements for the DC (%) were made in a FTIR Spectrometer Bomen (model MB-102, Quebec-Canada). The spectroscopy (FTIR) spectra for both uncured and cured samples were analyzed using an accessory for the diffuse reflectance. The measurements were recorded in the absorbance operating under the following conditions: 32 scans, 4-cm−1 resolution, and a 300 to 4000-cm−1 wavelength. The percentage of unreacted carbon-carbon double bonds (% C=C) was determined from the ratio of the absorbance intensities of aliphatic C=C (peak at 1638 cm−1) against an internal standard before and after the curing of the specimen: aromatic C-C (peak at 1608 cm−1). For the TR, the samples were made in a metallic mould (2-mm thickness and 4-mm diameter) and photoactivated during 5, 10, and 20 s. The thermocouple was attached to the multimeter to allow the temperature readings. The DC (%) and TR were calculated by the standard technique and submitted to ANOVA and Tukey’s test (p < 0.05). The degree of conversion values varied from 35.0 (±1.3) to 45.0 (±2.4) for 5 s, 45.0 (±1.3) to 55.0 (±2.4) for 10 s, and 47.0 (±1.3) to 52.0 (±2.4) for 20 s. For the TR, the values ranged from 0.3 (±0.01) to 5.4 (±0.11)°C for 5 s, from 0.5 (±0.02) to 9.3 (±0.28)°C for 10 s, and from 1.0 (±0.06) to 15.0 (±0.95)°C for 20 s. The power densities and irradiation times showed a significant effect on the degree of conversion and temperature rise.
The indirect adhesive procedures constitute recently a substantial portion of contemporary esthetic restorative treatments. The resin cements have been used to bond tooth substrate and restorative materials. Due to recently introduction of the self-bonding resin luting cement based on a new monomer, filler and initiation technology has become important to study the degree of conversion of these new materials. In the present work the polymerization reaction and the filler content of dual-cured dental resin cements were studied by means of infra-red spectroscopy (FT-IR) and thermogravimetry (TG). Twenty specimens were made in a metallic mold (8 mm diameter × 1 mm thick) from each of 2 cements, Panavia® F2.0 (Kuraray) and RelyX™ Unicem Applicap (3M/ESPE). Each specimen was cured with blue LED with power density of 500 mW/cm2 for 30 s. Immediately after curing, 24 and 48 h, and 7 days DC was determined. For each time interval 5 specimens were pulverized, pressed with KBr and analyzed with FT-IR. The TG measurements were performed in Netzsch TG 209 under oxygen atmosphere and heating rate of 10°C/min from 25 to 700°C. A two-way ANOVA showed DC (%) mean values statistically significance differences between two cements (p < 0.05). The Tukey’s test showed no significant difference only for the 24 and 48 h after light irradiation for both resin cements (p > 0.05). The Relx-Y™ Unicem mean values were significantly higher than Panavia® F 2.0. The degree of conversion means values increasing with the storage time and the filler content showed similar for both resin cements.
The purpose of this study was to evaluate the transmittance of seven different composite resins. Ten specimens were prepared (10 mm diameter, 2 mm thickness) for each experimental group, as follows: G1- Charisma® A 2 (Heraeus-Kulzer); G2- Filtek™ Supreme A 2E (3M/ESPE); G3- Filtek™ Supreme A2B (3M/ESPE); G4-Filtek™ Supreme YT (3M/ESPE); G5- Esthet-X® A2 (Dentsply); G6- Esthet-X® YE (Dentsply); G7- Durafill® A 2 (Heraeus-Kulzer) and G8- Filtek™ Z-100 A2 (3M/ESPE). The transmittance mode was measured using a UV-visible spectrophotometer (Cary Instruments) at 400-760 nm. The specimens were evaluated at three different times: zero hour (initial), 24 hours and 10 days after immersion in artificial saliva. The differences in transmittance were determined by two-way analysis of variance (ANOVA) and Tukey's test. The various composite resins showed significant differences in the wavelength dependence of transmittance. The mean values of transmittance increased significantly, with wavelengths increasing from 400 to 760 nm. The performance of the experimental groups was similar in terms of immersion time, considering that at time zero and after 10 days, all the groups showed similar results, which were statistically higher than the values obtained after 24 hours of immersion. The Filtek™ Supreme YT composite resin presented the highest mean transmittance values along the wavelengths at the three measured times. Esthet-X® YE and Durafill® yielded similar mean transmittance values, which were higher than those of the other groups. This study shows that the transmittance values of composite resins are directly related with the type, size and amount of inorganic filler particles
Different light sources and power densities used on the photoactivation process may provide changes in the degree of conversion (DC%) and temperature (T) of the composite resins. Thus, the purpose of this study was to evaluate the DC (%) and T (°C) of the microhybrid composite resin (Filtek™ Z-250, 3M/ESPE) photoactivated with one argon laser and one LED (light-emitting diode) with different power densities. For the KBr pellet technique, the composite resin was placed into a metallic mould (2-mm thickness, 4-mm diameter) and photoactivated as follows: a continuous argon laser (CW) and LED LCUs with power density values of 100, 400, 700, and 1000 mW/cm2 for 20 s. The measurements for DC (%) were made in a FTIR spectrometer Bomen (model MB 102, Quebec, Canada). Spectroscopy (FTIR) spectra for both uncured and cured samples were analyzed using an accessory of the reflectance diffusion. The measurements were recorded in absorbance operating under the following conditions: 32 scans, 4 cm−1 resolution, 300 to 4000-cm−1 wavelength. The percentage of unreacted carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1638 cm−1) against an internal standard before and after the curing of the specimen: aromatic C-C (peak at 1608 cm−1). For T (°C), the samples were created in a metallic mould (2-mm thickness, 4-mm diameter) and photoactivated for 20 s. The thermocouple was attached to the multimeter allowing temperature readings. The DC (%) and T (°C) were submitted to ANOVA and Tukey’s test (p < 0.05). The degree of conversion values varied from 35.0 to 50.0% (100 to 1000 mW/cm2) for an argon laser and from 41.0 to 49% (100 to 1000 mW/cm2) for an LED. The temperature change values varied from 1.1 to 13.1 °C (100 to 1000 mW/cm2) for an argon laser and from 1.9 to 15.0 °C (100 to 1000 mW/cm2) for an LED. The power densities showed a significant effect on the degree of conversion and changes the temperature for both lightcuring units.