Panayiotis Mavroidis

Prof. Panayiotis Mavroidis


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2010 in Journal of Contemporary Brachytherapy
Verified
Journal Article
Open access
PMPanayiotis Mavroidis
Panayiotis Mavroidis
ZKZaira Katsilieri
Zaira Katsilieri
VKVasiliki Kefala
Vasiliki Kefala
NMNatasa Milickovic
Natasa Milickovic
NPNikos Papanikolaou
Nikos Papanikolaou
DBDimos Baltas
Dimos Baltas
Purpose: One of the issues that a planner is often facing in HDR brachytherapy is the selective existence of high dose volumes around some few dominating dwell positions. If there is no information available about its necessity (e.g. location of a GTV), then it is reasonable to investigate...

18 May 2011 in Cancers
Verified
Journal Article
Open access
PDF file
MAMagdalena Adamus-Górka
Magdalena Adamus-Górka
PMPanayiotis Mavroidis
Panayiotis Mavroidis
BLBengt K. Lind
Bengt K. Lind
Anders BrahmeAnders Brahme
Anders Brahme
Seven different radiobiological dose-response models have been compared with regard to their ability to describe experimental data. The first four models, namely the critical volume, the relative seriality, the inverse tumor and the critical element models are mainly based on cell survival biology. The other three models: the Lyman (Gaussian distribution), the parallel architecture and the Weibull distribution models are semi-empirical and rather based on statistical distributions. The maximum likelihood estimation was used to fit the models to experimental data and the χ2-distribution, AIC criterion and F-test were applied to compare the goodness-of-fit of the models. The comparison was performed using experimental data for rat spinal cord injury. Both the shape of the dose-response curve and the ability of handling the volume dependence were separately compared for each model. All the models were found to be acceptable in describing the present experimental dataset (p > 0.05). For the white matter necrosis dataset, the Weibull and Lyman models were clearly superior to the other models, whereas for the vascular damage case, the Relative Seriality model seems to have the best performance although the Critical volume, Inverse tumor, Critical element and Parallel architecture models gave similar results. Although the differences between many of the investigated models are rather small, they still may be of importance in indicating the advantages and limitations of each particular model. It appears that most of the models have favorable properties for describing dose-response data, which indicates that they may be suitable to be used in biologically optimized intensity modulated radiation therapy planning, provided a proper estimation of their radiobiological parameters had been performed for every tissue and clinical endpoint.

3 July 2002 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PMPanayiotis Mavroidis
Panayiotis Mavroidis
KTKyriaki Theodorou
Kyriaki Theodorou
DLDimitrios Lefkopoulos
Dimitrios Lefkopoulos
FNFranccedilois Nataf
Franccedilois Nataf
MSMichel Schlienger
Michel Schlienger
Anders BrahmeAnders Brahme
Anders Brahme
This study was carried out in order to derive the radiobiological parameters of the dose-response relation for the obliteration of arteriovenous malformation (AVM) following single fraction stereotactic radiotherapy. Furthermore, the accuracy by which the linear Poisson model predicts the probability of obliteration and how the haemorrhage history, location and volume of the AVM influence its radiosensitivity are investigated. The study patient material consists of 85 patients who received radiation for AVM therapy. Radiation-induced AVM obliterations were assessed on the basis of post-irradiation angiographies and other radiological findings. For each patient the dose delivered to the clinical target volume and the clinical treatment outcome were available. These data were used in a maximum likelihood analysis to calculate the best estimates of the parameters of the linear Poisson model. The uncertainties of these parameters were also calculated and their individual influence on the dose-response curve was studied. AVM radiosensitivity was assumed to be the same for all the patients. The radiobiological model used was proved suitable for predicting the treatment outcome pattern of the studied patient material. The radiobiological parameters of the model were calculated for different AVM locations, bleeding histories and AVM sizes. The range of parameter variability had considerable effect on the dose-response curve of AVM. The correlation between the dosimetric data and their corresponding clinical effect could be accurately modelled using the linear Poisson model. The derived response parameters can be introduced into the clinical routine with the calculated accuracy assuming the same methodology in target definition and delineation. The known volume dependence of AVM radiosensitivity was confirmed. Moreover, a trend relating AVM location with its radiosensitivity was observed.

1 February 2011 in British Journal of Radiology
Verified
Journal Article
Closed access
PMPanayiotis Mavroidis
Panayiotis Mavroidis
CSC Shi
C Shi
GPG A Plataniotis
G A Plataniotis
MDM G Delichas
M G Delichas
BFBrigida Costa Ferreira
Brigida Costa Ferreira
NPN Papanikolaou
N Papanikolaou
Objectives: The aim of this study was to compare three-dimensional (3D) conformal radiotherapy and the two different forms of IMRT in lung cancer radiotherapy. Methods: Cases of four lung cancer patients were investigated by developing a 3D conformal treatment plan, a linac MLC-based step-and-shoot IMRT plan and an HT plan for each case. With the use of the complication-free tumour control probability (P+) index and the uniform dose concept as the common prescription point of the plans, the different treatment plans were compared based on radiobiological measures. Results: The applied plan evaluation method shows the MLC-based IMRT and the HT treatment plans are almost equivalent over the clinically useful dose prescription range; however, the 3D conformal plan inferior. At the optimal dose levels, the 3D conformal treatment plans give an average P+ of 48.1% for a effective uniform dose to the internal target volume (ITV) of 62.4 Gy, whereas the corresponding MLC-based IMRT treatment plans are more effect...

31 December 2010 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
ELEleftherios Lavdas
Eleftherios Lavdas
PMPanayiotis Mavroidis
Panayiotis Mavroidis
KVKaterina Vassiou
Katerina Vassiou
VRVioleta Roka
Violeta Roka
IFIoannis V. Fezoulidis
Ioannis V. Fezoulidis
MVMarianna Vlychou
Marianna Vlychou

27 April 2011 in Medical Physics
Verified
Journal Article
Closed access
PMPanayiotis Mavroidis
Panayiotis Mavroidis
BFBrigida Costa Ferreira
Brigida Costa Ferreira
MLMaria Do Carmo Lopes
Maria Do Carmo Lopes