Jean-Sébastien Roy

Prof. Jean-Sébastien Roy

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2009 in Arthritis Care & Research
Verified
Journal Article
Closed access
PDF file
JRJean-Sébastien Roy
Jean-Sébastien Roy
JMJoy C. MacDermid
Joy C. MacDermid
LWLinda J. Woodhouse
Linda J. Woodhouse

31 March 2019 in Sensors
Verified
Journal Article
Open access
PDF file
IPIsabelle Poitras
Isabelle Poitras
FDFrédérique Dupuis
Frédérique Dupuis
MBMathieu Bielmann
Mathieu Bielmann
Alexandre Campeau-LecoursAlexandre Campeau-Lecours
Alexandre Campeau-Lecours
Catherine MercierCatherine Mercier
Catherine Mercier
JRJean-Sébastien Roy
Jean-Sébastien Roy
Motion capture systems are recognized as the gold standard for joint angle calculation. However, studies using these systems are restricted to laboratory settings for technical reasons, which may lead to findings that are not representative of real-life context. Recently developed commercial and home-made inertial measurement sensors (M/IMU) are potentially good alternatives to the laboratory-based systems, and recent technology improvements required a synthesis of the current evidence. The aim of this systematic review was to determine the criterion validity and reliability of M/IMU for each body joint and for tasks of different levels of complexity. Five different databases were screened (Pubmed, Cinhal, Embase, Ergonomic abstract, and Compendex). Two evaluators performed independent selection, quality assessment (consensus-based standards for the selection of health measurement instruments [COSMIN] and quality appraisal tools), and data extraction. Forty-two studies were included. Reported validity varied according to task complexity (higher validity for simple tasks) and the joint evaluated (better validity for lower limb joints). More studies on reliability are needed to make stronger conclusions, as the number of studies addressing this psychometric property was limited. M/IMU should be considered as a valid tool to assess whole body range of motion, but further studies are needed to standardize technical procedures to obtain more accurate data.

11 February 2015 in British Journal of Sports Medicine
Verified
Journal Article
Open access
PDF file
JRJean-Sébastien Roy
Jean-Sébastien Roy
CBCaroline Braën
Caroline Braën
JLJean Leblond
Jean Leblond
FDFrançois Desmeules
François Desmeules
CDClermont E. Dionne
Clermont E. Dionne
PFPierre Frémont
Pierre Frémont
Background Different diagnostic imaging modalities, such as ultrasonography (US), MRI, MR arthrography (MRA) are commonly used for the characterisation of rotator cuff (RC) disorders. Since the most recent systematic reviews on medical imaging, multiple diagnostic studies have been published, most using more advanced technological characteristics. The first objective was to perform a meta-analysis on the diagnostic accuracy of medical imaging for characterisation of RC disorders. Since US is used at the point of care in environments such as sports medicine, a secondary analysis assessed accuracy by radiologists and non-radiologists. Methods A systematic search in three databases was conducted. Two raters performed data extraction and evaluation of risk of bias independently, and agreement was achieved by consensus. Hierarchical summary receiver-operating characteristic package was used to calculate pooled estimates of included diagnostic studies. Results Diagnostic accuracy of US, MRI and MRA in the characterisation of full-thickness RC tears was high with overall estimates of sensitivity and specificity over 0.90. As for partial RC tears and tendinopathy, overall estimates of specificity were also high (>0.90), while sensitivity was lower (0.67–0.83). Diagnostic accuracy of US was similar whether a trained radiologist, sonographer or orthopaedist performed it. Conclusions Our results show the diagnostic accuracy of US, MRI and MRA in the characterisation of full-thickness RC tears. Since full thickness tear constitutes a key consideration for surgical repair, this is an important characteristic when selecting an imaging modality for RC disorder. When considering accuracy, cost, and safety, US is the best option.

21 June 2012 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
FDFrançois Desmeules
François Desmeules
JRJean-Sébastien Roy
Jean-Sébastien Roy
JMJoy MacDermid
Joy MacDermid
FCFrançois Champagne
François Champagne
OHOdette Hinse
Odette Hinse
LWLinda June Woodhouse
Linda June Woodhouse
The convergence of rising health care costs and physician shortages have made health care transformation a priority in many countries resulting in the emergence of new models of care that often involve the extension of the scope of practice for allied health professionals. Physiotherapists in advanced practice/extended scope roles have emerged as key providers in such new models, especially in settings providing services to patients with musculoskeletal disorders. However, evidence of the systematic evaluation of advance physiotherapy practice (APP) models of care is scarce. A systematic review was done to update the evaluation of physiotherapists in APP roles in the management of patients with musculoskeletal disorders. Structured literature search was conducted in 3 databases (Medline, Cinahl and Embase) for articles published between 1980 and 2011. Included studies needed to present original quantitative data that addressed the impact or the effect of APP care. A total of 16 studies met all inclusion criteria and were included. Pairs of raters used four structured quality appraisal methodological tools depending on design of studies to analyse included studies. Included studies varied in designs and objectives and could be categorized in four areas: diagnostic agreement or accuracy compared to medical providers, treatment effectiveness, economic efficiency or patient satisfaction. There was a wide range in the quality of studies (from 25% to 93%), with only 43% of papers reaching or exceeding a score of 70% on the methodological quality rating scales. Their findings are however consistent and suggest that APP care may be as (or more) beneficial than usual care by physicians for patients with musculoskeletal disorders, in terms of diagnostic accuracy, treatment effectiveness, use of healthcare resources, economic costs and patient satisfaction. The emerging evidence suggests that physiotherapists in APP roles provide equal or better usual care in comparison to physicians in terms of diagnostic accuracy, treatment effectiveness, use of healthcare resources, economic costs and patient satisfaction. There is a need for more methodologically sound studies to evaluate the effectiveness APP care.

8 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MBMarianne Boyer
Marianne Boyer
Laurent BouyerLaurent Bouyer
Laurent Bouyer
JRJean-Sébastien Roy
Jean-Sébastien Roy
Alexandre Campeau-LecoursAlexandre Campeau-Lecours
Alexandre Campeau-Lecours
Electromyography (EMG) is gaining importance in many research and clinical applications, including muscle fatigue detection, control of robotic mechanisms and prostheses, clinical diagnosis of neuromuscular diseases and quantification of force. However, EMG signals can be contaminated by various types of noise, interference and artifacts, leading to potential data misinterpretation. Even assuming best practices, the acquired signal may still contain contaminants. The aim of this paper is to review methods employed to reduce the contamination of single channel EMG signals. Specifically, we focus on methods which enable a full reconstruction of the EMG signal without loss of information. This includes subtraction methods used in the time domain, denoising methods performed after the signal decomposition and hybrid approaches that combine multiple methods. Finally, this paper provides a discussion on the suitability of the individual methods based on the type of contaminant(s) present in the signal and the specific requirements of the application.

1 January 2015 in Journal of Foot and Ankle Research
Verified
Journal Article
Open access
PDF file
JEJean‐Francois Esculier
Jean‐Francois Esculier
BDBlaise Dubois
Blaise Dubois
CDClermont E. Dionne
Clermont E. Dionne
JLJean Leblond
Jean Leblond
JRJean-Sébastien Roy
Jean-Sébastien Roy
Background: While minimalist running shoes may have an influence on running biomechanics and on the incidence of overuse injuries, the term “minimalist” is currently used without standardisation. The objectives of this study were to reach a consensus on a standard definition of minimalist running shoes, and to develop and validate a rating scale that could be used to determine the degree of minimalism of running shoes, the Minimalist Index (MI).Methods: For this modified Delphi study, 42 experts from 11 countries completed four electronic questionnaires on an optimal definition of minimalist shoes and on elements to include within the MI. Once MI was developed following consensus, 85 participants subjectively ranked randomly assigned footwear models from the most to the least minimalist and rated their degree of minimalism using visual analog scales (VAS), before evaluating the same footwear models using MI. A subsample of thirty participants reassessed the same shoes on another occasion. Construct validity and inter‐ and intra‐rater reliability (intraclass correlation coefficients [ICC]; Gwet's AC1) of MI were evaluated.Results: The following definition of minimalist shoes was agreed upon by 95 % of participants: “Footwear providing minimal interference with the natural movement of the foot due to its high flexibility, low heel to toe drop, weight and stack height, and the absence of motion control and stability devices”. Characteristics to be included in MI were weight, flexibility, heel to toe drop, stack height and motion control/stability devices, each subscale carrying equal weighing (20 %) on final score. Total MI score was highly correlated with VAS (r = 0.91). A significant rank effect (p < 0.001) confirmed the MI's discriminative validity. Excellent intra‐ and inter‐rater reliability was found for total MI score (ICC = 0.84‐0.99) and for weight, stack height, heel to toe drop and flexibility subscales (AC1 = 0.82‐0.99), while good inter‐rater reliability was found for technologies (AC1 = 0.73).Conclusion: This standardised definition of minimalist shoes developed by an international panel of experts will improve future research on minimalist shoes and clinical recommendations. MI's adequate validity and reliability will allow distinguishing running shoes based on their degree of minimalism, and may help to decrease injuries related to footwear transition.