Stanislav Ďuriš

Prof. Stanislav Ďuriš


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
PGPatrik Grosinger
Patrik Grosinger
JRJan Rybář
Jan Rybář
ŠDŠtefan Dunaj
Štefan Dunaj
SĎStanislav Ďuriš
Stanislav Ďuriš
BHBranislav Hučko
Branislav Hučko
Measuring the swing angle of a crane load is a relatively well-known but unsatisfactorily solved problem in technical practice. This measurement is necessary for the automatic stabilization of load swing without human intervention. This article describes a technically simple and new approach to solving this problem. The focus of this work is to determine the accuracy of the measuring device. The focus of this work remains on the design, the principle of operation of the equipment, and the determination of accuracy. The basic idea is to apply the strain gauge on an elastic, easily deformable component that is part of the device. One part of the elastic component is fixedly connected to the frame; the other part is connected to the crane rope by means of pulleys close to the rope. In this way, the bending of the elastic component in proportion to the swing angle of the payload is ensured.

29 April 2016 in Measurement Techniques
Verified
Journal Article
Closed access
PDF file
RPR. Palencar
R. Palencar
SĎStanislav Ďuriš
Stanislav Ďuriš
ZDZ. Durisova
Z. Durisova
VBV. Brokes
V. Brokes
PPP. Pavlasek
P. Pavlasek

29 October 2018 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
JRJan Rybář
Jan Rybář
MCMiroslav Chytil
Miroslav Chytil
SĎStanislav Ďuriš
Stanislav Ďuriš
BHBranislav Hučko
Branislav Hučko
FMFilip Maukš
Filip Maukš
PPPeter Pavlásek
Peter Pavlásek
The article deals with types of artificial corneal material designed for the eye model, which is designed to calibrate the optical tonometers. This article is focused on the comparison of suitable materials for artificial cornea, measurement and evaluation of the data on the selected contact and non-contact optical tonometers. It sets partial conclusions for the calibration of optical tonometers in ophthalmological practice from the point of view of the materials used.

26 June 2015 in International Journal of Thermophysics
Verified
Journal Article
Closed access
PDF file
VWViktor Witkovský
Viktor Witkovský
GWGejza Wimmer
Gejza Wimmer
SĎStanislav Ďuriš
Stanislav Ďuriš

17 December 2019
Verified
Book Chapter
Closed access
PDF file
ĽKĽuboš Kučera
Ľuboš Kučera
JPJakub Palenčár
Jakub Palenčár
RPRudolf Palenčár
Rudolf Palenčár
SĎStanislav Ďuriš
Stanislav Ďuriš
Jan VachalekJan Vachalek
Jan Vachalek
JRJan Rybář
Jan Rybář

24 July 2026 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
JRJan Rybář
Jan Rybář
SZSohaibullah Zarghoon
Sohaibullah Zarghoon
SMSardar Maroofi
Sardar Maroofi
SSSayed Yousuf Sayed
Sayed Yousuf Sayed
SĎStanislav Ďuriš
Stanislav Ďuriš
POPeter Onderčo
Peter Onderčo
In this study a transient finite element model was developed to examine the temperature evolution of continuous casting blooms during reheating prior to rail rolling. The simulation was carried out using COMSOL Multiphysics 5.6, incorporating convective and radiative heat transfer mechanisms under a three-zone furnace (preheating, heating and soaking) temperature schedule. The temperature distribution and soaking uniformity were evaluated over a 7200 s heating cycle. The results indicate that proper adjustment of furnace setpoints enables the bloom center to reach approximately 1220 °C while maintaining acceptable temperature uniformity ∆T≤50 ℃. This study shows how numerical modeling can be used to improve thermal homogeneity prior to hot rolling and optimize reheating furnace performance.