Daniela Blessent

Daniela Blessent

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2011 in Advances in Water Resources
Verified
Journal Article
Closed access
Daniela BlessentDaniela Blessent
Daniela Blessent
RTRene Therrien
Rene Therrien
CGCarl W. Gable
Carl W. Gable

1 September 2009 in Computers & Geosciences
Verified
Journal Article
Closed access
Daniela BlessentDaniela Blessent
Daniela Blessent
RTRene Therrien
Rene Therrien
KMKerry MacQuarrie
Kerry MacQuarrie

5 March 2013 in Groundwater
Verified
Journal Article
Closed access
PDF file
Daniela BlessentDaniela Blessent
Daniela Blessent
PJPeter R. Jørgensen
Peter R. Jørgensen
RTRene Therrien
Rene Therrien

7 November 2018 in Energies
Verified
Journal Article
Open access
PDF file
MMMaria Isabel Velez Marquez
Maria Isabel Velez Marquez
JRJasmin Raymond
Jasmin Raymond
Daniela BlessentDaniela Blessent
Daniela Blessent
MPMikael Philippe
Mikael Philippe
NSNataline Simon
Nataline Simon
LLLouis Lamarche
Louis Lamarche
Thermal response tests are used to assess the subsurface thermal conductivity to design ground-coupled heat pump systems. Conventional tests are cumbersome and require a source of high power to heat water circulating in a pilot ground heat exchanger. An alternative test method using heating cable was verified in the field as an option to conduct this heat injection experiment with a low power source and a compact equipment. Two thermal response tests using heating cable sections and a continuous heating cable were performed in two experimental heat exchangers on different sites in Canada and France. The temperature evolution during the tests was monitored using submersible sensors and fiber optic distributed temperature sensing. Free convection that can occur in the pipe of the heat exchanger was evaluated using the Rayleigh number stability criterion. The finite and infinite line source equations were used to reproduce temperature variations along the heating cable sections and continuous heating cable, respectively. The thermal conductivity profile of each site was inferred and the uncertainly of the test was evaluated. A mean thermal conductivity 15% higher than that revealed with the conventional test was estimated with heating cable sections. The thermal conductivity evaluated using the continuous heating cable corresponds to the value estimated during the conventional test. The average uncertainly associated with the heating cable section test was 15.18%, while an uncertainty of 2.14% was estimated for the test with the continuous heating cable. According to the Rayleigh number stability criterion, significant free convection can occur during the heat injection period when heating cable sections are used. The continuous heating cable with a low power source is a promising method to perform thermal response tests and further tests could be carried out in deep boreholes to verify its applicability.

9 January 2024 in Energy
Verified
Journal Article
Closed access
HShamza semmari
hamza semmari
FBFoued bouaicha
Foued bouaicha
SASofiane Aberkane
Sofiane Aberkane
Abdelkader FilaliAbdelkader Filali
Abdelkader Filali
Daniela BlessentDaniela Blessent
Daniela Blessent
MBMessaoud Badache
Messaoud Badache