Yasue Mitsukura

Prof. Dr. Yasue Mitsukura

Keio University

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2018 in Sensors
Verified
Journal Article
Open access
PDF file
MOMikito Ogino
Mikito Ogino
YMYasue Mitsukura
Yasue Mitsukura
Drowsiness detection has been studied in the context of evaluating products, assessing driver alertness, and managing office environments. Drowsiness level can be readily detected through measurement of human brain activity. The electroencephalogram (EEG), a device whose application relies on adhering electrodes to the scalp, is the primary method used to monitor brain activity. The many electrodes and wires required to perform an EEG place considerable constraints on the movement of users, and the cost of the device limits its availability. For these reasons, conventional EEG devices are not used in practical studies and businesses. Many potential practical applications could benefit from the development of a wire-free, low-priced device; however, it remains to be elucidated whether portable EEG devices can be used to estimate human drowsiness levels and applied within practical research settings and businesses. In this study, we outline the development of a drowsiness detection system that makes use of a low-priced, prefrontal single-channel EEG device and evaluate its performance in an offline analysis and a practical experiment. Firstly, for the development of the system, we compared three feature extraction methods: power spectral density (PSD), autoregressive (AR) modeling, and multiscale entropy (MSE) for detecting characteristics of an EEG. In order to efficiently select a meaningful PSD, we utilized step-wise linear discriminant analysis (SWLDA). Time-averaging and robust-scaling were used to fit the data for pattern recognition. Pattern recognition was performed by a support vector machine (SVM) with a radial basis function (RBF) kernel. The optimal hyperparameters for the SVM were selected by the grind search method so as to increase drowsiness detection accuracy. To evaluate the performance of the detections, we calculated classification accuracy using the SVM through 10-fold cross-validation. Our model achieved a classification accuracy of 72.7% using the PSD with SWLDA and the SVM. Secondly, we conducted a practical study using the system and evaluated its performance in a practical situation. There was a significant difference (* p < 0.05) between the drowsiness-evoked task and concentration-needed task. Our results demonstrate the efficacy of our low-priced portable drowsiness detection system in quantifying drowsy states. We anticipate that our system will be useful to practical studies with aims as diverse as measurement of classroom mental engagement, evaluation of movies, and office environment evaluation.

26 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
BSBrian Sumali
Brian Sumali
YMYasue Mitsukura
Yasue Mitsukura
KLKuo-Ching Liang
Kuo-Ching Liang
MYMichitaka Yoshimura
Michitaka Yoshimura
MKMomoko Kitazawa
Momoko Kitazawa
TKTaishiro Kishimoto
Taishiro Kishimoto
Loss of cognitive ability is commonly associated with dementia, a broad category of progressive brain diseases. However, major depressive disorder may also cause temporary deterioration of one’s cognition known as pseudodementia. Differentiating a true dementia and pseudodementia is still difficult even for an experienced clinician and extensive and careful examinations must be performed. Although mental disorders such as depression and dementia have been studied, there is still no solution for shorter and undemanding pseudodementia screening. This study inspects the distribution and statistical characteristics from both dementia patient and depression patient, and compared them. It is found that some acoustic features were shared in both dementia and depression, albeit their correlation was reversed. Statistical significance was also found when comparing the features. Additionally, the possibility of utilizing machine learning for automatic pseudodementia screening was explored. The machine learning part includes feature selection using LASSO algorithm and support vector machine (SVM) with linear kernel as the predictive model with age-matched symptomatic depression patient and dementia patient as the database. High accuracy, sensitivity, and specificity was obtained in both training session and testing session. The resulting model was also tested against other datasets that were not included and still performs considerably well. These results imply that dementia and depression might be both detected and differentiated based on acoustic features alone. Automated screening is also possible based on the high accuracy of machine learning results.

5 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
YMYasue Mitsukura
Yasue Mitsukura
BSBrian Sumali
Brian Sumali
MNMasaki Nagura
Masaki Nagura
KFKoichi Fukunaga
Koichi Fukunaga
Masato YasuiMasato Yasui
Masato Yasui
Ballistocardiogram (BCG) is a graphical representation of the subtle oscillations in body movements caused by cardiovascular activity. Although BCGs cause less burden to the user, electrocardiograms (ECGs) are still commonly used in the clinical scene due to BCG sensors’ noise sensitivity. In this paper, a robust method for sleep time BCG measurement and a mathematical model for predicting sleep stages using BCG are described. The novel BCG measurement algorithm can be described in three steps: preprocessing, creation of heartbeat signal template, and template matching for heart rate variability detection. The effectiveness of this algorithm was validated with 99 datasets from 36 subjects, with photoplethysmography (PPG) to compute ground truth heart rate variability (HRV). On average, 86.9% of the inter-beat intervals were detected and the mean error was 8.5ms. This shows that our method successfully extracted beat-to-beat intervals from BCG during sleep, making its usability comparable to those of clinical ECGs. Consequently, compared to other conventional BCG systems, even more accurate sleep heart rate monitoring with a smaller burden to the patient is available. Moreover, the accuracy of the sleep stages mathematical model, validated with 100 datasets from 25 subjects, is 80%, which is higher than conventional five-stage sleep classification algorithms (max: 69%). Although, in this paper, we applied the mathematical model to heart rate interval features from BCG, theoretically, this sleep stage prediction algorithm can also be applied to ECG-extracted heart rate intervals.

19 February 2019 in Health Informatics Journal
Verified
Journal Article
Open access
PDF file
YMYasue Mitsukura
Yasue Mitsukura
KFKoichi Fukunaga
Koichi Fukunaga
MYMasato Yasui
Masato Yasui
MMMasaru Mimura
Masaru Mimura
Getting enough quality sleep plays a vital role in protecting our mental health, physical health, and quality of life. Sleep deprivation can make it difficult to concentrate on daily activities, and lower sleep quality is associated with hypertension, hyperglycemia, and hyperlipidemia. The amount of sleep we get is important, but in recent years, quality sleep has also been deemed significant. Polysomnography, which has been the gold standard in assessing sleep quality based on stages, requires that the subject be attached to electrodes, which can disrupt sleep. An easier method to objectively measure sleep is therefore needed. The aim of this study was to construct an easy and objective sleep stage monitoring method. A cross-sectional study for healthy subjects has been done in our research. A new easy model for monitoring the sleep stages is built on only heart rate calculated by the electrocardiogram. This enabled us to easily assess the sleep quality based on five stages. This experiment included a total of 50 subjects. The overall accuracy in determining the five sleep stages was 66.0 percent. Four stages for sleep are identified accurately compared with other conventional methods. Despite there are no five sleep stage separation method using only heart rate, our method achieved the five separation for sleep with a relatively good accuracy. This study represents a great contribution to the field of sleep science. Because sleep stages can be recognized by the heart rate alone, sleep can be noninvasively assessed with any heart rate meter. This method will make it easier to determine sleep stages and diagnose sleep disorders.

22 April 2022 in BMC Psychiatry
Verified
Journal Article
Open access
PDF file
YMYasue Mitsukura
Yasue Mitsukura
BSBrian Sumali
Brian Sumali
HWHideto Watanabe
Hideto Watanabe
TIToshiharu Ikaga
Toshiharu Ikaga
TNToshihiko Nishimura
Toshihiko Nishimura
Background: Previous studies using EEG (electroencephalography) as biomarker for dementia have attempted to research, but results have been inconsistent. Most of the studies have extremely small number of samples (average N = 15) and studies with large number of data do not have control group. We identified EEG features that may be biomarkers for dementia with 120 subjects (dementia 10, MCI 33, against control 77). Methods: We recorded EEG from 120 patients with dementia as they stayed in relaxed state using a single-channel EEG device while conducting real-time noise reduction and compared them to healthy subjects. Differences in EEG between patients and controls, as well as differences in patients’ severity, were examined using the ratio of power spectrum at each frequency. Results: In comparing healthy controls and dementia patients, significant power spectrum differences were observed at 3 Hz, 4 Hz, and 10 Hz and higher frequencies. In patient group, differences in the power spectrum were observed between asymptomatic patients and healthy individuals, and between patients of each respective severity level and healthy individuals. Conclusions: A study with a larger sample size should be conducted to gauge reproducibility, but the results implied the effectiveness of EEG in clinical practice as a biomarker of MCI (mild cognitive impairment) and/or dementia.

1 January 2016 in Journal of Signal Processing
Verified
Journal Article
Open access
YMYasue Mitsukura
Yasue Mitsukura