Metal matrix syntactic foams (MMSFs) are becoming increasingly relevant from the lightweight structural materials point of view. They are also used as energy absorbers and as core materials for sandwich structures. The mechanical properties of MMSFs are extensively influenced by the properties of their filler materials which are used to create and ensure the porosity inside the metal matrix. As the properties of fillers are of such importance in the case of MMSFs, in this paper three different filler materials: (i) ceramic hollow spheres (CHSs), (ii) metallic hollow spheres (MHSs) and (iii) lightweight expanded clay particles (LECAPs), have been investigated in numerous aspects. The investigations cover the microstructural features of the fillers and the basic mechanical properties of the fillers and the produced MMSFs as well. The microstructure was studied by optical and electron microscopy extended by energy-dispersive X-ray spectrometry, while the basic mechanical properties were mapped by standardized compression tests. It was found that in the terms of cost-awareness the LECAPs are the best fillers, because they are ~100 times cheaper than the CHSs or MHSs, but their mechanical properties can be compared to the aforementioned, relatively expensive filler materials and still exceed the properties of the most ‘conventional’ metallic foams.
Aluminum alloy (Al99.5 or AlSi12)-based metal matrix syntactic foams (MMSFs) were produced by pressure infiltration with ~65 vol % Globocer filler (33 wt % Al2O3, 48 wt % SiO2, 19 wt % Al2O3∙SiO2). The infiltrated blocks were machined by different geometry tools in order to produce notched samples. The samples were loaded in three-point bending, and the loading force values were recorded against the cross-head displacements and the crack opening displacements. To measure up the notch sensitivity and toughness of the MMSFs, the fracture energies and the fracture toughness values were determined. The results showed that the mentioned quantities are needed to describe the behavior of MMSFs. The fracture energies were shown to be notch-sensitive, while the fracture toughness values were dependent only on the matrix material and were insensitive to the notch geometry. The complex investigation of the fracture surfaces revealed strong bonding between the hollow spheres and the Al99.5 matrix due to a chemical reaction, while this bonding was found to be weaker in the case of the AlSi12 matrix. This difference resulted in completely different crack propagation modes in the case of the different matrices.
In this study two different types of hollow sphere were examined by mechanical, geometrical and microstructural measurements, and the fracture force, geometrical properties and chemical composition were determined. The diameter of the „01 globocer” type specimens was 2.37 mm on average, while the value for the „03 globocer” type specimens was 6.88 mm, both were smaller than the nominal diameter. The average deviation from the circularity of the 01 globocer specimens was 8 %, the value for the 03 globocer specimens was 6 %, while the average wall porosity was 53±3 % and 56±3 % respectively. The surface of the hollow spheres was uneven, which has an impact on the contact surfaces during pressure tests, which affects the fracture force values. The average value of the fracture force of 01 globocer spheres was 42 N, and of 03 globocer hollow spheres was 288 N. The diameter had a bigger impact on the fracture force values of the type 01 specimens than in the case of 03.
As cellular materials are gaining more ground in the automotive, airplane, and railway industries, the demand for functionally graded metal foams has appeared. In the case of syntactic metal foams, by changing the distribution of the filler material, the properties of the foams can be precisely adjusted according to the desired area of application. Several kinds of graded aluminum matrix syntactic foams (GMSFs) were fabricated with lightweight expanded clay aggregate particles and ceramic hollow spheres as filler materials. Their mechanical properties were observed by modal analysis and compression tests, supplemented with an accurate density determination by computer tomography measurements. The compressive properties were set up on a large scale by adjusting the density by adding specific amounts of Al particles to the filler. Based on the modal analysis results, simple averaging the density of GMSFs produces an inaccurate result in mode shapes and material parameters, so the varying density distributions should be taken into account. By simply varying the distribution of the filler material, we can modify the effective material properties of metal foams to better fit industrial requirements.
Additive manufacturing (AM) is becoming increasingly important, making it possible to produce a product in a short time, to specific individual requirements, and even in the presence of the customer. This research is related to direct metal laser sintering of additive manufacturing. This new technology is increasingly being used in more sectors, for example in biomedical industry, where a damaged product can potentially endanger human life. Corrosion tests were carried out during our research. Cyclic voltammetry curves and corrosion rates were determined with a potentiostat. Two typical biocompatible implant materials were compared, a cobalt chromium alloy (powder metallurgy) and a titanium alloy (3D printed). The results will help in specifying the corrosion properties of additively manufactured materials.
During implantation, stents are delivered in crimped state to the narrowed lesion, where they are expanded to the desired size by the balloon. Due to insufficient size selection or high resistance to plaque, the stent is often widened by the expansion pressure to a level greater than the nominal pressure specified by the manufacturer. Depending on the degree of overpressure, the nominal diameter of the stent may change by several tenths of a millimetre. Numerous studies have dealt with the physiological effects of overexposure and stenogenic stress, but so far no studies have been carried out to investigate the stent coating and corrosion properties of the stent. In our research a widely used drug-eluting, platinum-chromium alloyed steel stent was observed with an inflation pressure of 12 and 18 bar. Scanning electron microscopy revealed lesions of the coating and potentiodynamic tests were performed to determine the corrosion rate.