Eunmin Cho

Dr. Eunmin Cho


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
ECEunmin Cho
Eunmin Cho
HJHyungjin Jeon
Hyungjin Jeon
DYDan Ki Yoon
Dan Ki Yoon
SPSi Hyun Park
Si Hyun Park
HHHyong JIn Hong
Hyong JIn Hong
Lee Cheol MinLee Cheol Min
Lee Cheol Min
Currently, low-cost, sensor-based fine dust measurement devices are commercially available in South Korea. This study evaluated the reliability of three such devices—Yi Shan A4, Plantower PMS7003, and Plantower PMS7003—in comparison to long-term consecutive monitoring systems for discharge and prevention facilities regarding fine dust control. The performance of these devices for concentration intervals over time was examined through real-time comparison using a GRIMM (Model: 11-A, dust spectrometer from Grimm Technologies) as a reference; this included a correction factor (C-Factor), calculated by a gravimetric method and an equivalence test. For comparison, the reference and target devices were installed in a chamber with fine dust concentrations of 2 µg/m3, with temperature and humidity maintained at 20 °C and 40%, respectively. The fine particulate matter (PM)2.5 concentrations were classified into five intervals: ≤40 µg/m3, 40–80 µg/m3, 80–120 µg/m3, 120–160 µg/m3, and 200–230 µg/m3. Statistical analysis was performed using data obtained from national stations for monitoring and controlling fine dust released from facilities under high fine dust loading conditions. The results showed that the measurements of all target devices, which were corrected according to the reference device, provided accurate values at PM2.5 concentrations of ≥40 µg/m3. The statistical analysis results suggest that the evaluated devices are more reliable than the conventional numerical-analysis-based monitoring system

ECEunmin Cho
Eunmin Cho
HHHyong JIn Hong
Hyong JIn Hong
SPSi Hyun Park
Si Hyun Park
DYDan Ki Yoon
Dan Ki Yoon
SGSun Ju Nam Goung
Sun Ju Nam Goung
Lee Cheol MinLee Cheol Min
Lee Cheol Min
The aim of this study was to support management of airborne bacteria in facilities used by pollution-sensitive individuals (in daycares, medical facilities, elder care facilities, and postnatal care centers). A field survey was conducted on 11 facilities from October 2017 to April 2018. Elder care facilities in industrial, urban, and forested areas were excluded. Two indoor, and one outdoor, measuring points were selected per facility. These points were located in areas most often used by the residents. Measurements were taken at random time-points before February 2018 and at specific times in the morning and afternoon thereafter. The relationships among bacterial counts, carbon dioxide concentrations, dust levels, temperature, relative humidity, and ventilation were examined. The pooled average bacterial counts at the daycares, medical facilities, elder care facilities, and postnatal care centers were 540.25 CFU m−3, 245.49 CFU m−3, 149.63 CFU m−3, and 169.65 CFU m−3, respectively. Considering the upper 95% confidence interval, the bacterial counts in many daycares may in fact be >800 CFU m−3, which is the threshold set by the Korean Ministry of the Environment. The pooled average indoor: outdoor bacterial count ratio was 1.13. Indoor airborne bacterial counts were influenced mainly by their sources. This study found no significant correlations among indoor temperature, relative humidity, carbon dioxide concentration, dust levels, and airborne bacterial counts, unlike previous studies. Airborne bacteria management at daycares should be a top priority. The sources of airborne bacteria must also be identified, and a management plan must be developed to control them.

29 April 2016 in BioChip Journal
Verified
Journal Article
Closed access
PDF file
SJSeok-Won Jang
Seok-Won Jang
MOMin-Su Oh
Min-Su Oh
SYSung Yang
Sung Yang
ECEunmin Cho
Eunmin Cho