Christine Azevedo Coste

Dr. Christine Azevedo Coste

Inria
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2014 in Sensors
Verified
Journal Article
Open access
PDF file
CCChristine Azevedo Coste
Christine Azevedo Coste
BSBenoît Sijobert
Benoît Sijobert
RPRoger Pissard-Gibollet
Roger Pissard-Gibollet
MPMaud Pasquier
Maud Pasquier
BEBernard Espiau
Bernard Espiau
CGChristian Geny
Christian Geny
Freezing of gait (FOG) is a common symptom in Parkinsonism, which affects the gait pattern and is associated to a fall risk. Automatized FOG episode detection would allow systematic assessment of patient state and objective evaluation of the clinical effects of treatments. Techniques have been proposed in the literature to identify FOG episodes based on the frequency properties of inertial sensor signals. Our objective here is to adapt and extend these FOG detectors in order to include other associated gait pattern changes, like festination. The proposed approach is based on a single wireless inertial sensor placed on the patient’s lower limbs. The preliminary experimental results show that existing frequency-based freezing detectors are not sufficient to detect all FOG and festination episodes and that the observation of some gait parameters such as stride length and cadence are valuable inputs to anticipate the occurrence of upcoming FOG events.

23 December 2015 in Sensors
Verified
Journal Article
Open access
PDF file
MBMourad Benoussaad
Mourad Benoussaad
BSBenoît Sijobert
Benoît Sijobert
KMKatja Mombaur
Katja Mombaur
CCChristine Azevedo Coste
Christine Azevedo Coste
This paper introduces a method for the robust estimation of foot clearance during walking, using a single inertial measurement unit (IMU) placed on the subject’s foot. The proposed solution is based on double integration and drift cancellation of foot acceleration signals. The method is insensitive to misalignment of IMU axes with respect to foot axes. Details are provided regarding calibration and signal processing procedures. Experimental validation was performed on 10 healthy subjects under three walking conditions: normal, fast and with obstacles. Foot clearance estimation results were compared to measurements from an optical motion capture system. The mean error between them is significantly less than 15 % under the various walking conditions.

1 January 2014 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
DGDavid Guiraud
David Guiraud
CCChristine Azevedo Coste
Christine Azevedo Coste
MBMourad Benoussaad
Mourad Benoussaad
CFCharles Fattal
Charles Fattal
Experience of an implanted functional electrical stimulation neuroprosthesis (FES) associating 8-channel epimysial and 4-channel neural stimulations. The primary objective consisted in presenting clinical and technological experiences based on a 9-year follow-up of one patient implanted with this FES device. The secondary objective consisted in assessing resulting functional benefits. One patient recruited in 1996 within the European Stand Up and Walk Project benefited from a 9-year follow-up with clinical and technological evaluations. The patient was still using the system nine years later making this a unique case, even when compared to other similar studies. The analysis of muscular response to FES underlined the great variability of stimulation thresholds evolution (-26% to +360%, mean +110%) and quality of the induced contraction. Three muscles out of five scored at least 4/5 on the Medical Research Council scale, all stimulated via neural pathways. The patient used the system once a week for 6 years, up to 2006, due to lack of use, the FES-induced muscular response worsened even though the implant was properly functioning, leading to significant decline in gait performances (best 3.45 m/s on 2.9 m), due to muscle fatigue and loss of muscle mass. Two major issues arise: first the importance of muscle fatigue, underlining the relevance of muscle strength training, and second technological hurdles raising up the question of neural vs. epimysial FES. This advanced technology proves the concept of restoring lower limb motor functions in patients with spinal cord injury. The main features of the stimulation device remain stable even after long periods of inactivity, yet there is a real need for close clinical and technological monitoring.

6 October 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
CCChristine Azevedo Coste
Christine Azevedo Coste
LWLucie William
Lucie William
LFLucas Fonseca
Lucas Fonseca
AHArthur Hiairrassary
Arthur Hiairrassary
DADavid Andreu
David Andreu
DGDavid Guiraud
David Guiraud
Individuals with complete cervical spinal cord injury suffer from a permanent paralysis of upper limbs which prevents them from achieving most of the activities of daily living. We developed a neuroprosthetic solution to restore hand motor function. Electrical stimulation of the radial and median nerves by means of two epineural electrodes enabled functional movements of paralyzed hands. We demonstrated in two participants with complete tetraplegia that selective stimulation of nerve fascicles by means of optimized spreading of the current over the active contacts of the multicontact epineural electrodes induced functional and powerful grasping movements which remained stable over the 28 days of implantation. We also showed that participants were able to trigger the activation of movements of their paralyzed limb using an intuitive interface controlled by voluntary actions and that they were able to perform useful functional movements such as holding a can and drinking through a straw.

11 February 2025 in Sensors
Verified
Journal Article
Open access
PDF file
VMValentin Maggioni
Valentin Maggioni
CCChristine Azevedo Coste
Christine Azevedo Coste
SDSam Durand
Sam Durand
FBFrançois Bailly
François Bailly
Ensuring the accurate tracking of hand and fingers movements is an ongoing challenge for upper limb rehabilitation assessment, as the high number of degrees of freedom and segments in the limited volume of the hand makes this a difficult task. The objective of this study is to evaluate the performance of two markerless approaches (the Leap Motion Controller and the Google MediaPipe API) in comparison to a marker-based one, and to improve the precision of the markerless methods by introducing additional data processing algorithms fusing multiple recording devices. Fifteen healthy participants were instructed to perform five distinct hand movements while being recorded by the three motion capture methods simultaneously. The captured movement data from each device was analyzed using a skeletal model of the hand through the inverse kinematics method of the OpenSim software. Finally, the root mean square errors of the angles formed by each finger segment were calculated for the markerless and marker-based motion capture methods to compare their accuracy. Our results indicate that the MediaPipe-based setup is more accurate than the Leap Motion Controller-based one (average root mean square error of 10.9° versus 14.7°), showing promising results for the use of markerless-based methods in clinical applications.

18 October 2019 in Sensors
Verified
Journal Article
Open access
PDF file
LFLucas Fonseca
Lucas Fonseca
WTWafa Tigra
Wafa Tigra
BNBenjamin Navarro
Benjamin Navarro
DGDavid Guiraud
David Guiraud
CFCharles Fattal
Charles Fattal
CCChristine Azevedo Coste
Christine Azevedo Coste
Individuals who sustained a spinal cord injury often lose important motor skills, and cannot perform basic daily living activities. Several assistive technologies, including robotic assistance and functional electrical stimulation, have been developed to restore lost functions. However, designing reliable interfaces to control assistive devices for individuals with C4–C8 complete tetraplegia remains challenging. Although with limited grasping ability, they can often control upper arm movements via residual muscle contraction. In this article, we explore the feasibility of drawing upon these residual functions to pilot two devices, a robotic hand and an electrical stimulator. We studied two modalities, supra-lesional electromyography (EMG), and upper arm inertial sensors (IMU). We interpreted the muscle activity or arm movements of subjects with tetraplegia attempting to control the opening/closing of a robotic hand, and the extension/flexion of their own contralateral hand muscles activated by electrical stimulation. Two groups were recruited: eight subjects issued EMG-based commands; nine other subjects issued IMU-based commands. For each participant, we selected at least two muscles or gestures detectable by our algorithms. Despite little training, all participants could control the robot’s gestures or electrical stimulation of their own arm via muscle contraction or limb motion.