In this paper a concept of finite impulse response (FIR) narrow band-stop (notch) filter with non-zero initial conditions, based on infinite impulse response (IIR) prototype filter, is proposed. The filter described in this paper is used to suppress power line noise from ECG signals. In order to reduce the transient response of the proposed FIR notch filter, optimal initial conditions for the filter have been determined. The algorithm for finding the length of the initial conditions vector is presented. The proposed values of the length of initial conditions vector, for several ECG signals and interfering frequencies, are calculated. The proposed filters are tested using various ECG signals. Computer simulations demonstrate that the proposed FIR filters outperform traditional FIR filters with initial conditions set to zero.
18 December 2020 in IEEE Transactions on Instrumentation and Measurement
In this article, an analytical concept and hardware verification of the time-varying infinite impulse response narrow multiband-stop filter with nonzero initial conditions are presented. The time variability of the filter parameters and nonzero initial conditions are introduced to the filter structure in order to reduce its transient response. Such a filter can be very useful in various measurement systems. In particular, short transient filters are very desirable for processing signals whose initial part is of great importance. In this article, the algorithm for finding the length of the initial conditions vector is presented. As an example, the proposed IIR multinotch filter is used for removing power-line interferences from the ECG signal. Computer simulations, hardware verification, and performance indices demonstrate that the proposed time-varying IIR multinotch filter with nonzero initial conditions possesses much better properties than the traditional time-invariant filter with zero initial conditions.
9 May 2022 in IEEE Transactions on Instrumentation and Measurement
In the paper, a concept of digital time-efficient IIR elliptic notch filters with a reduced transient response is presented. The proposed notch filter is designed to effectively suppress power line interferences from short-latency evoked potentials. Desired time-domain properties of the considered filter have been achieved through a time-varying stop-band width and non-zero initial values of the filter. The designed filter has been verified with the use of the brainstem auditory evoked potential (BAEP) corrupted by the power line noise. The results of simulations and performance indices prove that the proposed parameter-varying elliptic notch filter with non-zero initial values is definitely more effective in removing the power line interference than commonly used time-invariant filters with zero initial values.
In this paper a concept of the second order digital infinite impulse response narrow band-reject filter with reduced transient response is proposed. In order to suppress the transient response of the considered infinite impulse response (IIR) notch filter its pole radius is temporarily varied in time using the Bézier parametric curve. Computer simulations verifying the effectiveness of the proposed pole-radius-varying notch filter are presented and compared to the performance of the traditional time-invariant filter using ECG signals distorted by unwanted powerline interference.
In this paper a concept of infinite impulse response narrow multi-band-stop time-varying filter based on all-pass prototype filter is proposed. The IIR multi-notch filter is used for removing power-line interferences from biomedical sources such as ECG. In order to reduce the duration of the transient state of the proposed IIR multi-notch filter, the parameters of the all-pass prototype filter are temporarily varied in time. The proposed filter is tested using sinusoidal and ECG signals. Computer simulations and performance indexes demonstrate that the proposed time-varying IIR multi-notch filter based on the all-pass prototype filter possesses better properties than traditional time-invariant IIR multi-notch filter.
In this paper a digital FIR notch filter used for removing power-line interference from biomedical recordings is presented. A concept of finite impulse response narrow bandstop time-varying filter with non-zero initial conditions, based on linear Kalman notch prototype filter, is proposed. In order to reduce the duration of the transient response of the proposed FIR notch filter, a parameter of the Kalman notch prototype filter is temporarily varied in time. Moreover, optimal initial conditions for the proposed FIR filter have been determined. The presented filters are tested using sinusoidal and EEG signal. Computer simulations demonstrate that the proposed time-varying FIR filters outperform traditional time-invariant FIR filters with initial conditions set to zero.