There is a discussion in Europe about the dominant role of air pollution for health effects, most researchers claim that the particulate matter is responsible for inflammatory processes in the respiratory system, while others underline the role of nitrogen dioxide. The aim of the study was to assess the risk related to NOx, NO2 and PM2.5 concentration increase and daily outpatient visits or hospitalization due to bronchitis and asthma exacerbation in the entire population of Silesian Voivodeship, Poland. To assess the relationship between daily pollutants concentrations and the number of outpatient visits or hospitalizations due to bronchitis and asthma (available in the regional registry), the multivariable log-linear Poisson regression model was used. Results were presented by relative risk (RR) of health outcomes related to the increase in pollutant concentration by unit (interquartile range). Obtained results confirmed a statistically significant association between outpatient visits and hospitalizations due to bronchitis and asthma exacerbation and daily nitrogen oxides concentrations in Silesian voivodeship, Poland. The strongest relationship was observed in the case of NO2 and outpatient visits due to bronchitis, e.g., RR = 1.434 (1.308–1.571) for exposure expressed by the 50-day moving average concentration. In the case of hospitalizations, the health effect was lagged a few days in relation to the increase in exposure.
13 March 2017 in International Journal of Environmental Science and Technology
The aim of this study was to characterize both the viable airborne bacteria and fungi collected in different types of wastewater treatment plants in Poland. Bacterial and fungal aerosols in five different wastewater treatment plants in Poland were studied, including the pioneering antibiotic resistance testing of airborne bacteria. Concentration level was measured using the six-stage Andersen impactor. After incubation, bioaerosol particles captured on nutrient media on Petri dishes were quantitatively evaluated and qualitatively identified. It was found that the concentration levels of both airborne bacteria and fungi ranged from 10² to 10³ colony-forming units/m³, in all stages of the wastewater treatment plants. The patterns of size distributions of airborne bacteria and fungi were very similar, showing dominant peaks typically in the size range between 3.3 and 4.7 μm. The majority fraction of small bacterial and fungal particles (less than 4.7 μm) in the studied areas indicates that the bioaerosol is relatively fresh, and mostly of local origin. The Gram-positive cocci and nonsporing Gram-positive rods were the dominating forms in the studied wastewater treatment plants environment. The existing differences in the concentration levels between sampling sites enabled identification of the main bioaerosol sources. The highest concentration of bacterial aerosol appeared in sections, where activated sludge post-processing and mechanical purifying are conducted. The most frequently occurring species in the sampled bacterial aerosol were Gram-positive cocci and nonsporing Gram-positive rods. Multi-antibiotic resistance testing showed that among the isolated airborne bacteria, the most antibiotic-resistant features were present among Bacillus species (especially Bacillus mycoides).
The ability to measure and control the composition of activated sludge is an important issue, aiming at evaluating the effectiveness of changes occurring in the sludge, what determines its usefulness to treat wastewater. In this research, diffuse reflectance infrared Fourier transform (FTIR–DRIFT) technique was used, which relies on measuring the reflectance of the powdered substance’s surface layer and capturing spectra in range of infrared wave. First, spectra correlation table of the substances mostly occurring in wastewater was developed to assess the main components of the tested samples of activated sludge. The simplest compounds containing functional groups characteristic for particular chemical classes were chosen: peptides (peptone and albumin), fats (glycerin and fatty acids), carbohydrates (glucose and sucrose), nitrogen compounds (NaNO3 and NH4SO4), sulfur compounds (Na2SO4 and Na2S2O3), silicate, etc. The spectra of those substances were captured and characteristic absorption bands for respective bonds in the function groups were assigned. Second, samples of activated sludge from lab-scale membrane bioreactors (MBRs), which purifies petroleum wastewater, were taken. Samples were properly prepared (lyophilization and homogenization) and their spectra were captured. During spectra analysis, previously developed correlation table was used. In obtained spectra of activated sludge, absorption bonds characteristic for amides, peptides, carbohydrates, fats, and aliphatic was identified. The spectra profile of the sludge sample from MBR feed with petroleum wastewater was slightly different from the control MBR sample’s spectra. Intensity of bands in the area characteristic for aliphatic compounds and phenols was clearly higher. This study proves the usefulness of FT-IR technique to observe changes in the chemical composition of activated sludge.
20 June 2018 in Annals of Agricultural and Environmental Medicine
Bioaerosols are particularly sensitive to sterilization processes due to their biological characteristics. Phenomena occurring in the atmosphere have major influence on airborne bacteria and fungi concentration levels. The presented study evaluates the sterilization properties of ambient air temperature and solar radiation on viable bioaerosols concentration levels in outdoor air in Gliwice, Poland. Assigned were the breakpoints indicating limited stimulation properties of the air temperature, which amounted 7.5°C for bacterial aerosol and 16.5 °C for fungal aerosol. Also revealed was the influence of solar radiation properties on decreasing the bioaerosols concentration levels. Both bacterial and fungal viable aerosol were sensitive to this radiation, although the phenomenon was more effective for airborne bacteria.
The relationship between the worsening of air quality during the colder season of the year and respiratory health problems among the exposed population in many countries located in cold climates has been well documented in numerous studies. Silesian Voivodeship, a region located in southern Poland, is one of the most polluted regions in Europe. The aim of this study was to assess the relationship between daily concentration of particulate matter (PM: PM2.5 and PM10) in ambient air and exacerbations of respiratory diseases during the period from 1 January 2016 to 31 August 2017 in the central agglomeration area of Silesian Voivodeship. The study results confirmed a significant increase of daily fine particulate matter concentration in ambient air during the cold season in Silesian Voivodeship with a simultaneous increase of the number of outpatient visits and hospitalizations due to respiratory diseases. The moving average concentration was better suited for the modelling of biological response as a result of PM2.5 or PM10 exposure than the temporal lag of health effects. Each increase of dose expressed in the form of moving average concentration over a longer time leads to an increase in the daily number of respiratory effects. The highest risk of hospitalization due to respiratory diseases was related to longer exposure of PM expressed by two to four weeks of exposure; outpatient visits was related to a shorter exposure duration of 3 days.
The main aim of this work is the estimation of health risks arising from exposure to ozone or other air pollutants by different statistical models taking into account delayed health effects. This paper presents the risk of hospitalization due to bronchitis and asthma exacerbation in adult inhabitants of Silesian Voivodeship from 1 January 2016 to 31 August 2017. Data were obtained from the daily register of hospitalizations for acute bronchitis (code J20–J21, International Classification of Diseases, Tenth Revision – ICD-10) and asthma (J45–J46) which is governed by the National Health Fund. Meteorological data and data on tropospheric ozone concentrations were obtained from the regional environmental monitoring database of the Provincial Inspector of Environmental Protection in Katowice. The paper includes descriptive and analytical statistical methods used in the estimation of health risk with a delayed effect: Almon Distributed Lag Model, the Poisson Distributed Lag Model, and Distributed Lag Non-Linear Model (DLNM). A significant relationship has only been confirmed by DLNM for bronchitis and a relatively short period (1–3 days) from exposure above the limit value (120 µg/m3). The relative risk value was RR = 1.15 (95% CI 1.03–1.28) for a 2-day lag. However, conclusive findings require the continuation of the study over longer observation periods.