In articular cartilage, chondrocytes are surrounded by a pericellular matrix (PCM), which together with the chondrocyte have been termed the “chondron.” While the precise function of the PCM is not known there has been considerable speculation that it plays a role in regulating the biomechanical environment of the chondrocyte. In this study, we measured the Young’s modulus of the PCM from normal and osteoarthritic cartilage using the micropipette aspiration technique, coupled with a newly developed axisymmetric elastic layered half-space model of the experimental configuration. Viable, intact chondrons were extracted from human articular cartilage using a new microaspiration-based isolation technique. In normal cartilage, the Young’s modulus of the PCM was similar in chondrons isolated from the surface zone (68.9±18.9 kPa) as compared to the middle and deep layers (62.0±30.5 kPa). However, the mean Young’s modulus of the PCM (pooled for the two zones) was significantly decreased in osteoarthritic cartilage (66.5±23.3 kPa versus 41.3±21.1 kPa, In combination with previous theoretical models of cell-matrix interactions in cartilage, these findings suggest that the PCM has an important influence on the stress-strain environment of the chondrocyte that potentially varies with depth from the cartilage surface. Furthermore, the significant loss of PCM stiffness that was observed in osteoarthritic cartilage may affect the magnitude and distribution of biomechanical signals perceived by the chondrocytes.
4 January 2011 in Annals of Biomedical Engineering
In this paper, we analyze how elastic and viscoelastic properties differ across seven locations along the large arteries in 11 sheep. We employ a two-parameter elastic model and a four-parameter Kelvin viscoelastic model to analyze experimental measurements of vessel diameter and blood pressure obtained invitro at conditions mimicking invivo dynamics. Elastic and viscoelastic wall properties were assessed via solutions to the associated inverse problem. We use sensitivity analysis to rank the model parameters from the most to the least sensitive, as well as to compute standard errors and confidence intervals. Results reveal that elastic properties in both models (including Young's modulus and the viscoelastic relaxation parameters) vary across locations (smaller arteries are stiffer than larger arteries). We also show that for all locations, the inclusion of viscoelastic behavior is important to capture pressure-area dynamics.