This paper presents a laboratory investigation of hydraulic conductivity of municipal solid waste (MSW) in landfills and provides a comparative assessment of measured hydraulic conductivity values with those reported in the literature based on laboratory and field studies. A series of laboratory tests was conducted using shredded fresh and landfilled MSW from the Orchard Hills landfill (Illinois, United States) using two different small-scale and large-scale rigid-wall permeameters and a small-scale triaxial permeameter. Fresh waste was collected from the working phase, while the landfilled waste was exhumed from a borehole in a landfill cell subjected to leachate recirculation for approximately 1.5 years. The hydraulic conductivity tests conducted on fresh MSW using small-scale rigid-wall permeameter resulted in a range of hydraulic conductivity 2.8× 10−3 –11.8× 10−3 cm/s with dry unit weight varied in a narrow range between 3.9–5.1 kN/ m3 . The landfilled MSW tested using the same permeameter produced ...
In foundation designs, standard penetration test (SPT) blow counts are typically used to estimate shear strength properties of soils. Few correlations are widely in use to make such estimations. However, the selection of these correlation equations are not often justified or explained. This manuscript describes a new approach to estimate the shear strength properties based on the SPT blow counts. The proposed method treats SPT analogous to driving a miniature open-ended pipe pile. During SPT, part of the energy is transferred into the soil. This energy is dissipated at the soil-sampler interface to overcome skin and point resistance to penetrate a sampler into the soil. Energy balance was used to correlate the SPT blow count to the shear strength properties of the soil at the depth of testing. Two separate equations were derived: one to estimate the friction angle ( ϕ′ ) of sand and the other to estimate the undrained shear strength ( cu ) of clay. SPT results from two sites were used to calibrate the pro...
The subsurface exploration of a site is often the aspect of a project that gets overlooked during the design process. Many clients will get standard soil borings, but do not want to pay for a full laboratory analysis. Lack of data forces the designer to estimate important engineering properties of the soil. Very often the Standard Penetration Test (SPT) blow counts are used to estimate the shear strength properties of soil in foundation designs. Few correlations are widely used. However, no clear explanation is found to justify the selection most of these mathematical equations. This manuscript describes a new approach to estimate the shear strength parameters based on the SPT blow counts. In this method, the standard penetration test is treated analogous to driving a miniature pipe pile. The energy input to the soil is used to correlate the SPT blow count to the shear strength parameters of the soil at the depth of testing. Soil boring records from few different sites were analyzed and a statistical analysis revealed that the proposed method can provide a better estimation than the widely used existing correlations.
This paper compares the geotechnical properties of fresh municipal solid waste (MSW) to landfilled MSW obtained from a bioreactor landfill. Fresh MSW samples were collected from the working face of Orchard Hills Landfill. Landfilled MSW (15–19 months old, subjected to intermittent very low flow leachate recirculation for a year) samples were recovered from a borehole located near a multi-level horizontal leachate recirculation system in the same landfill. Laboratory testing was performed on shredded samples to determine the variation in in-situ moisture content, organic content, biochemical methane potential (BMP), specific gravity, density, hydraulic conductivity, compressibility, and shear strength properties of fresh as well as landfilled MSW. In-situ dry gravimetric moisture content of fresh MSW was around 44% and landfilled MSW varied between 21–43%. Organic content of the fresh MSW was 76% whereas degradation and presence of other components in landfilled MSW resulted in organic content between 62–68%. Due to the presence of finer particles, reconstituted dry density of landfilled MSW was 601–712 kg/m3 whereas fresh waste was 515 kg/m3. For confining pressure greater than 69 kPa, both fresh and landfilled waste possessed similar hydraulic conductivity. Compressibility test results showed higher strains for fresh MSW than for the landfilled, with compression index of 0.28 for fresh and 0.22 for landfilled MSW. Based on direct shear testing, shear strength properties for fresh MSW were: c'=47 kPa and φ'=290 and for landfilled MSW were: c'=12 kPa and φ'=320. Overall, this study shows that the changes in geotechnical properties of waste subjected to low overall rates of leachate recirculation for a year are not significant; however, additional research is warranted to quantify changes in properties of waste under longer-term leachate recirculation.
1 October 2013 in Journal of Hazardous, Toxic, and Radioactive Waste
This manuscript presents a detailed discussion of the challenges faced and lessons learned during the initial phase of operation of the Calgary Biocell. The Calgary Biocell is a full-scale pilot project that has been implemented to acquire data and demonstrate the applicability of the biocell concept under severe winter conditions. The biocell concept involves operating a waste cell in three phases: first as an anaerobic bioreactor to recover biogas and produce energy, second as an aerobic bioreactor or an in-ground composter, and finally mined to recover processed waste and land for reuse. The Calgary Biocell has been in operation in its first phase, as an anaerobic bioreactor, for over the past five years. The cell was equipped with sensors to gather performance data during anaerobic and aerobic bioreactor operation. The settlement, moisture content, pressure, and temperature sensors provided early data, but failed after several months of cell operation. Regular monitoring and repairs were perfo...