“Skin-core-skin” structure is a typical crystal morphology in injection products. Previous numerical works have rarely focused on crystal evolution; rather, they have mostly been based on the prediction of temperature distribution or crystallization kinetics. The aim of this work was to achieve the “skin-core-skin” structure and investigate the role of external flow and temperature fields on crystal morphology. Therefore, the multiscale algorithm was extended to the simulation of polymer crystallization in a pipe flow. The multiscale algorithm contains two parts: a collocated finite volume method at the macroscopic level and a morphological Monte Carlo method at the microscopic level. The SIMPLE (semi-implicit method for pressure linked equations) algorithm was used to calculate the polymeric model at the macroscopic level, while the Monte Carlo method with stochastic birth-growth process of spherulites and shish-kebabs was used at the microscopic level. Results show that our algorithm is valid to predict “skin-core-skin” structure, and the initial melt temperature and the maximum velocity of melt at the inlet mainly affects the morphology of shish-kebabs.
Molecular dynamics simulations on the nonisothermal crystallization of a single polyethylene chain and short polyethylene chains based on the all-atom model and optimized potentials for liquid simulations-all atom (OPLS-AA) force field are conducted in this article. Four all-atom single chain models with different chain lengths (C1000, C2000, C3000, and C4000) and four all-atom short chain models with the same chain length and different number of chains (2C500, 4C500, 6C500, and 8C500) are constructed. The collapse process at a high temperature of 600 K and the nonisothermal crystallization process with different cooling rates at the temperature range of 600–300 K are simulated. Roles of chain length, number of chains, cooling rate on the potential energy, van der Waals ( Vdw ) energy, radius of gyration, root mean square deviation, and crystallinity are explored. By comparing with the existing results obtained by the united atom model, the validity and accuracy of this study are proved. Results show that in the collapse process, the chain length is the major factor, whereas the cooling rate has the greatest influence during the nonisothermal crystallization process. As the cooling rate decreases, a “platform” appeared in the Vdw energy curve, which has a profound impact on the crystallization.
Polymers are poor heat conductors, so the cooling of thick-walled shapes results in temperature gradients. Here, isotactic polypropylene (iPP) is chosen as a model polymer for the study of polymer crystallization in a temperature gradient field. The morphological Monte Carlo algorithm is applied, combined with the radius growth model, to predict the growth of spherulites. Through comparison of the two numerical solutions, analytical solution and experimental data, the validity of the morphological Monte Carlo algorithm is demonstrated. In addition, the roles of central temperature, temperature gradient for the evolution of spherulites, and the conversion degree of the melt into spherulites are considered. The results of the study show that increases in central temperature and temperature gradient can increase the anisotropy of spherulites. Isothermal crystallization and crystallization in a temperature gradient field are compared, and the differences are considered. Results show that when the central temperature is below 125 °C, and when the temperature gradients are less than 15 K/mm and 27 K/mm, the differences in the conversion degree of the melt into spherulites are less than 2% and 5%, respectively. Therefore, crystallization under such temperature gradient conditions can be simplified as isothermal crystallization.
The population balance equation (PBE) is the main governing equation for modeling dynamic crystallization behavior. In the view of mathematics, PBE is a convection–reaction equation whose strong hyperbolic property may challenge numerical methods. In order to weaken the hyperbolic property of PBE, a diffusive term was added in this work. Here, the Chebyshev spectral collocation method was introduced to solve the PBE and to achieve accurate crystal size distribution (CSD). Three numerical examples are presented, namely size-independent growth, size-dependent growth in a batch process, and with nucleation, and size-dependent growth in a continuous process. Through comparing the results with the numerical results obtained via the second-order upwind method and the HR-van method, the high accuracy of Chebyshev spectral collocation method was proven. Moreover, the diffusive term is also discussed in three numerical examples. The results show that, in the case of size-independent growth (PBE is a convection equation), the diffusive term should be added, and the coefficient of the diffusive term is recommended as 2G × 10−3 to G × 10−2, where G is the crystal growth rate.
Superhydrophobic surfaces have garnered attention for their ability to decrease fluid resistance, which can significantly reduce energy consumption. This study aims to accurately capture critical flow phenomena in a microchannel and explore the internal drag-reduction mechanism of the flow field. To achieve this, the three-dimensional (3D) superhydrophobic surface flow field with conical microstructure is numerically simulated using the gas–liquid two-phase flow theory and Volume of Fluid (VOF) model, combined with a Semi-implicit method for the pressure-linked equation (SIMPLE) algorithm. The surface drag-reduction effect of the conical microstructure is investigated and compared it to that of the V-longitudinal groove and V-transverse groove surfaces. Additionally, the changes in the drag-reduction effect during the wear of the conical microstructure were explored. The numerical results reveal that the drag-reduction effect improves with a larger period spacing of the conical microstructure, the drag reduction rate can reach 25.23%. As the height of the conical microstructure increases, the aspect ratio (ratio of width to height) decreases, and the dimensionless pressure drop ratio and the drag-reduction ratio increase. When the aspect ratio approaches 1, the drag reduction rate can reach over 28%. indicating a more effective drag-reduction. The microstructure is most effective in reducing drag at the beginning of the wear period but becomes less effective as the wear level increases, when the high wear reaches 10, the drag reduction rate decreases to 3%. Compared to the V-shaped longitudinal groove and V-shaped transverse grooves, the conical microstructure is the most effective in reducing drag.
1 January 2024 in Computer Modeling in Engineering & Sciences
Transient heat conduction problems widely exist in engineering. In previous work on the peridynamic differential operator (PDDO) method for solving such problems, both time and spatial derivatives were discretized using the PDDO method, resulting in increased complexity and programming difficulty. In this work, the forward difference formula, the backward difference formula, and the centered difference formula are used to discretize the time derivative, while the PDDO method is used to discretize the spatial derivative. Three new schemes for solving transient heat conduction equations have been developed, namely, the forward-in-time and PDDO in space (FT-PDDO) scheme, the backward-in-time and PDDO in space (BT-PDDO) scheme, and the central-in-time and PDDO in space (CT-PDDO) scheme. The stability and convergence of these schemes are analyzed using the Fourier method and Taylor’s theorem. Results show that the FT-PDDO scheme is conditionally stable, whereas the BT-PDDO and CT-PDDO schemes are unconditionally stable. The stability conditions for the FT-PDDO scheme are less stringent than those of the explicit finite element method and explicit finite difference method. The convergence rate in space for these three methods is two. These constructed schemes are applied to solve one-dimensional and two-dimensional transient heat conduction problems. The accuracy and validity of the schemes are verified by comparison with analytical solutions.