Urban areas are often warmer than rural areas due to the phenomenon known as the “urban heat island” (UHI) effect, which can cause discomfort for those engaging in outdoor activities and can have a disproportionate impact on low-income communities, people of color, and the elderly. The intensity of the UHI effect is influenced by a variety of factors, including urban morphology, which can vary from one area to another. To investigate the relationship between outdoor thermal comfort and urban morphology in different urban blocks with varying social vulnerability status, this study developed a geographic information system (GIS)-based workflow that combined the “local climate zone” (LCZ) classification system and an urban microclimate assessment tool called ENVI-met. To demonstrate the effectiveness of this methodology, the study selected two different urban blocks in Philadelphia, Pennsylvania–with high and low social vulnerability indices (SVI)–to compare their microclimate conditions in association with urban morphological characteristics such as green coverage area, sky view factor (SVF), albedo, and street height to width (H/W) ratio. The results of the study showed that there was a strong correlation between tree and grass coverage and outdoor air and mean radiant temperature during hot seasons and extremely hot days, which in turn affected simulated predicted mean vote (PMV). The effects of greenery were more significant in the block associated with a low SVI, where nearly 50% of the site was covered by trees and grass, compared to only 0.02% of the other block associated with a high SVI. Furthermore, the investigation discovered that reduced SVF, along with increased albedo and H/W ratio, had a beneficial impact on the microclimate at the pedestrian level within the two studied urban blocks. This study provided an effective and easy-to-implement method for tackling the inequity issue of outdoor thermal comfort and urban morphology at fine geographic scales.
The integration of distributed renewable energy technologies (such as building-integrated photovoltaics (BIPV)) into buildings, especially in space-constrained urban areas, offers sustainable energy and helps offset fossil-fuel-related carbon emissions. However, the intermittent nature of these distributed renewable energy sources can negatively impact the larger power grids. Efficient onsite energy storage solutions capable of providing energy continuously can address this challenge. Traditional large-scale energy storage methods like pumped hydro and compressed air energy have limitations due to geography and the need for significant space to be economically viable. In contrast, electrochemical storage methods like batteries offer more space-efficient options, making them well suited for urban contexts. This literature review aims to explore potential substitutes for batteries in the context of solar energy. This review article presents insights and case studies on the integration of electrochemical energy harvesting and storage into buildings. The seamless integration can provide a space-efficient source of renewable energy for new buildings or existing structures that often have limited physical space for retrofitting. This work offers a comprehensive examination of existing research by reviewing the strengths and drawbacks of various technologies for electrochemical energy harvesting and storage, identifying those with the potential to integrate into building skins, and highlighting areas for future research and development.
Masonry screen walls are architectural elements made from bricks that create different patterns to provide shade and natural ventilation to buildings. This paper presents a digital framework for the design of masonry screen walls, whose performance as environmental control elements is optimized while complying with vernacular construction rules. The framework employs shape grammars for creating a generative design system based on existing construction rules. This design system is then translated into a parametric model and connected to a simulation engine that calculates daylight metrics and cooling energy loads. A genetic algorithm is then used to find a family of optimized solutions, with visual feedback being provided to facilitate the understanding of trade-offs between such solutions. The proposed framework is tested with a case study, in which design solutions are generated by manipulating selected design variables to find optimal design solutions in terms of environmental performance. .
In the 1950s, architect William Hajjar built a four-story research building with a two-story double-skin facade (DSF) on all four building sides with the intention to explore solar heat control strategies: in winter, the movement of warm air from sun-exposed DSFs toward the cold sides to reduce heating loads, and in summer, the removal of the DSF’s warm air to reduce cooling loads. The article presents archival studies, computational fluid dynamics simulations, and smoke experiments, all undertaken to explore the performance of four-sided DSFs with regard to heat distribution and airflow patterns in winter. The studies confirm the potentials to create a temperature equilibrium around the facade and reduce heating loads. However, excessive heat build-up in the DSFs on clear days remains challenging.
21 August 2026 in Energy Conversion and Management