Jiang Du

Prof. Dr. Jiang Du

Department of Radiology, University of California, San Diego, CA 92122, USA
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2010 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
Jiang DuJiang Du
Jiang Du
MCMichael Carl
Michael Carl
MBMark Bydder
Mark Bydder
ATAtsushi Takahashi
Atsushi Takahashi
CCChristine B. Chung
Christine B. Chung
GBGraeme M. Bydder
Graeme M. Bydder

20 December 2011 in Journal of Bone and Mineral Research
Verified
Journal Article
Open access
PDF file
WBWon C Bae
Won C Bae
PCPeter C Chen
Peter C Chen
CCChristine B Chung
Christine B Chung
KMKoichi Masuda
Koichi Masuda
DDDarryl D'lima
Darryl D'lima
Jiang DuJiang Du
Jiang Du
In this study we describe the use of ultrashort echo time (UTE) magnetic resonance imaging (MRI) to evaluate short and long T2* components as well as the water content of cortical bone. Fourteen human cadaveric distal femur and proximal tibia were sectioned to produce 44 rectangular slabs of cortical bone for quantitative UTE MR imaging, microcomputed tomography (µCT), and biomechanical testing. A two‐dimensional (2D) UTE pulse sequence with a minimal nominal TE of 8 µseconds was used together with bicomponent analysis to quantify the bound and free water in cortical bone using a clinical 3T scanner. Total water concentration was measured using a 3D UTE sequence together with a reference water phantom. UTE MR measures of water content (total, free, and bound), T2* (short and long), and short and long T2* fractions were compared with porosity assessed with µCT, as well as elastic (modulus, yield stress, and strain) and failure (ultimate stress, failure strain, and energy) properties, using Pearson correlation. Porosity significantly correlated positively with total (R2 = 0.23; p < 0.01) and free (R2 = 0.31; p < 0.001) water content as well as long T2* fraction (R2 = 0.25; p < 0.001), and negatively with short T2* fraction and short T2* (R2 = 0.24; p < 0.01). Failure strain significantly correlated positively with short T2* (R2 = 0.29; p < 0.001), ultimate stress significantly correlated negatively with total (R2 = 0.25; p < 0.001) and bound (R2 = 0.22; p < 0.01) water content, and failure energy significantly correlated positively with both short (R2 = 0 30; p < 0.001) and long (R2 = 0.17; p < 0.01) T2* values. These results suggest that UTE MR measures are sensitive to the structure and failure properties of human cortical bone, and may provide a novel way of evaluating cortical bone quality. © 2012 American Society for Bone and Mineral Research.

28 December 2012 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
Jiang DuJiang Du
Jiang Du
GBGraeme M. Bydder
Graeme M. Bydder

1 May 2011 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
Jiang DuJiang Du
Jiang Du
MBMark Bydder
Mark Bydder
ATAtsushi M. Takahashi
Atsushi M. Takahashi
MCMichael Carl
Michael Carl
CCChristine B. Chung
Christine B. Chung
GBGraeme M. Bydder
Graeme M. Bydder

27 October 2011 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
Jiang DuJiang Du
Jiang Du
EDEric Diaz
Eric Diaz
MCMichael Carl
Michael Carl
WBWon Bae
Won Bae
CCChristine B. Chung
Christine B. Chung
GBGraeme M. Bydder
Graeme M. Bydder
Biological tissues frequently contain different water compartments, and these often have distinct transverse relaxation times. Quantification of these may be problematic on clinical scanners because spin echo sequences usually have initial echo times that are too long to accurately quantify shorter relaxation time components. In this study, an ultrashort echo time pulse sequence was used together with bicomponent analysis to quantify both the short and long T2 components in tissues of the musculoskeletal system. Feasibility studies were performed using numerical simulation, and on phantoms and in vitro tissues including bovine cortical bone, ligaments, menisci, tendons, and articular cartilage. The simulation and phantom studies demonstrated that this technique can quantify T2* and fractions of the short and long T2 components. The tissues studies showed two distinct components with short T2*s ranging from 0.3 ms for bovine cortical bone to 2.1 ms for menisci, and long T2*s ranging from 2.9 ms for bovine cortical bone to 35.0 ms for articular cartilage. The short T2* fraction ranged from 18.5% for patella cartilage to 80.9% for ligaments. The results show that ultrashort echo time imaging with bicomponent analysis can quantify the short and long T2 water components in vitro in musculoskeletal tissues. Magn Reson Med, 2012.

1 February 2014 in NeuroImage
Verified
Journal Article
Closed access
Jiang DuJiang Du
Jiang Du
GMGuolin Ma
Guolin Ma
SLShihong Li
Shihong Li
MCMichael Carl
Michael Carl
NSNikolaus M. Szeverenyi
Nikolaus M. Szeverenyi
GBGraeme M. Bydder
Graeme M. Bydder