Background Acquired long QT syndrome is a reversible condition that can lead to torsades de pointes and sudden cardiac death. Objective To determine the frequency, onset, frequency of medications, and risk factors for the syndrome in intensive care patients. Methods In a retrospective chart review of 88 subjects, hourly corrected QT intervals calculated by using the Bazett formula were collected. Acquired long QT syndrome was defined as a corrected QT of 500 milliseconds or longer or an increase in corrected QT of 60 milliseconds or greater from baseline level. Risk factors and medications administered were collected from patients’ medical records. Results The syndrome occurred in 46 patients (52%); mean time of onset was 7.4 hours (SD, 9.4) from time of admission. Among the 88 patients, 52 (59%) received a known QTc-prolonging medication. Among the 46 with the syndrome, 23 (50%) received a known QT-prolonging medication. No other risk factor studied was significantly predictive of the syndrome. Conclusions Acquired long QT syndrome occurs in patients not treated with a known QT-prolonging medication, indicating the importance of frequent QT monitoring of all intensive care patients.
24 March 2014 in Journal of the American Heart Association
Background: Over 140 million iP ads ® have been sold worldwide. The iP ad2 ® , with magnets embedded in its frame and Smart Cover and 3G cellular data capability, can potentially cause electromagnetic interference in implantable cardioverter defibrillators. This can lead to potentially life‐threatening situations in patients. The goal of this study was to determine whether the iP ad2 ® can cause electromagnetic interference in patients with implantable cardioverter defibrillators. Methods and Results: Twenty‐seven patients with implantable cardioverter defibrillators were studied. The iP ad2 ® was held at reading distance and placed directly over the device with cellular data capability activated and deactivated. The manufacturers/models of devices and the patients' body mass index were noted. The presence of electromagnetic interference was detected by using a programmer supplied by each manufacturer. Magnet mode with suspension of anti‐tachycardia therapy was triggered in 9 (33%) patients. All occurred when the iP ad2 ® was placed directly over the device. The cellular data status did not cause interference and no noise or oversensing was noted. There was no significant difference between the mean body mass index of the groups with or without interference. Conclusions: The iP ad2 ® can trigger magnet mode in implantable cardioverter defibrillators when laid directly over the device. This is potentially dangerous if patients should develop life‐threatening arrhythmias at the same time. As new electronic products that use magnets are produced, the potential risk to patients with implantable defibrillators needs to be addressed.
According to the Centers for Disease Control and Prevention statistics, about 6.2 million adults in the United States have heart failure. Guideline-Directed Medical Therapy (GDMT) involving the use of renin-angiotensin-aldosterone system inhibitors with or without a neprilysin inhibitor, β-blockers, mineralocorticoid-receptor-antagonists, and sodium-glucose cotransporter-2 inhibitors serve as the backbone for heart failure with reduced ejection fraction (HFrEF) therapy. However, in patients with refractory hypotension, the initiation of GDMT may not be possible. We present four cases where the use of midodrine, an alpha adrenergic agonist, serves as bridge therapy for the initiation or continuation of GDMT with marked clinical improvement. These cases illustrate how exacerbations of HFrEF may be ameliorated with outpatient midodrine titration among patients with baseline, persistent hypotension such that GDMT may be better tolerated.