Paul S. Pagel

Paul S. Pagel


Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2003 in Anesthesiology
Verified
Journal Article
Closed access
PPPaul S. Pagel
Paul S. Pagel
FKFranz Kehl
Franz Kehl
MGMeir Gare
Meir Gare
DHDouglas A. Hettrick
Douglas A. Hettrick
JKJudy R. Kersten
Judy R. Kersten
DWDavid C. Warltier
David C. Warltier

22 August 2011 in Anaesthesia
Verified
Journal Article
Open access
PDF file
PPPaul S. Pagel
Paul S. Pagel
JHJ. A. Hudetz
J. A. Hudetz
Summary: The h‐index is used to evaluate scholarly productivity in academic medicine, but has not been extensively used in anaesthesia. We analysed the publications, citations, citations per publication and h‐index from 1996 to date using the Scopus ® database for 1630 (1120 men, 510 women) for faculty members from 24 randomly selected US academic anaesthesiology departments The median (interquartile range [range]) h‐index of US academic anaesthesiologists was 1 [0–5 (0–44)] with 3 [0–18 (0–398)] total publications, 24 [0–187 (0–8515)] total citations, and 5 [0–14 (0–252)] citations per publication. Faculty members in departments with National Institutes of Health funding were more productive than colleagues in departments with little or no government funding. The h‐index increased significantly between successive academic ranks concomitant with increases in the number of publications and total citations. Men had higher median h‐index than women concomitant with more publications and citations, but the number of citations per publication was similar between groups. Our results suggest that h‐index is a reasonable indicator of scholarly productivity in anaesthesia. The results may help comparisons of academic productivity across countries and may be used to assess whether new initiatives designed to reverse recent declines in academic anaesthetic are working. You can respond to this article at http://www.anaesthesiacorrespondence.com

1 September 2007 in Anesthesia & Analgesia
Verified
Journal Article
Closed access
PPPaul S. Pagel
Paul S. Pagel
JKJohn G. Krolikowski
John G. Krolikowski
YSYon Hee Shim
Yon Hee Shim
SVSuneetha Venkatapuram
Suneetha Venkatapuram
JKJudy R. Kersten
Judy R. Kersten
PPPhillip F. Pratt
Phillip F. Pratt
Survival signaling kinases [including phosphatidylinositol-3-kinase, extracellular signal-regulated kinase, and 70-kDa ribosomal protein s6 kinase] and inhibition of mitochondrial permeability transition pore (mPTP) opening in vivo. METHODS: Rabbits (n = 98) instrumented for hemodynamic measurement and subjected to a 30-min left anterior descending coronary artery (LAD) occlusion and 3 h reperfusion received 0.9% saline (control), three cycles of 70% He-, Ne-, or Ar-30% O2 administered for 5 min interspersed with 5 min of 70% N2–30% O2 before LAD occlusion, or three cycles of brief (5 min) ischemia interspersed with 5 min reperfusion before prolonged LAD occlusion and reperfusion (ischemic preconditioning). Additional groups of rabbits received selective inhibitors of phosphatidylinositol-3-kinase (wortmannin; 0.6 mg/kg), extracellular signal-regulated kinase (PD 098059; 2 mg/kg), or 70-kDa ribosomal protein s6 kinase (rapamycin; 0.25 mg/kg) or mPTP opener atractyloside (5 mg/kg) in the absence or presence of He pretreatment. RESULTS: He, Ne, Ar, and ischemic preconditioning significantly (P < 0.05) reduced myocardial infarct size [23% ± 4%, 20% ± 3%, 22% ± 2%, 17% ± 3% of the left ventricular area at risk (mean ± sd); triphenyltetrazolium chloride staining] versus control (45% ± 5%). Wortmannin, PD 098059, rapamycin, and atractyloside alone did not affect infarct size, but these drugs abolished He-induced cardioprotection. CONCLUSIONS: The results indicate that noble gases without anesthetic properties produce cardioprotection by activating prosurvival signaling kinases and inhibiting mPTP opening in rabbits....

16 June 2006 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
JLJohn F LaDisajr
John F LaDisajr
LOLars E Olson
Lars E Olson
HDHettrick A Douglas
Hettrick A Douglas
DWDavid C Warltier
David C Warltier
JKJudy R Kersten
Judy R Kersten
PPPaul S. Pagel
Paul S. Pagel
Background: The success of stent implantation in the restoration of blood flow through areas of vascular narrowing is limited by restenosis. Several recent studies have suggested that the local geometric environment created by a deployed stent may influence regional blood flow characteristics and alter distributions of wall shear stress (WSS) after implantation, thereby rendering specific areas of the vessel wall more susceptible to neointimal hyperplasia and restenosis. Stents are most frequently implanted in curved vessels such as the coronary arteries, but most computational studies examining blood flow patterns through stented vessels conducted to date use linear, cylindrical geometric models. It appears highly probable that restenosis occurring after stent implantation in curved arteries also occurs as a consequence of changes in fluid dynamics that are established immediately after stent implantation. Methods: In the current investigation, we tested the hypothesis that acute changes in stent-induced regional geometry influence distributions of WSS using 3D coronary artery CFD models implanted with stents that either conformed to or caused straightening of the primary curvature of the left anterior descending coronary artery. WSS obtained at several intervals during the cardiac cycle, time averaged WSS, and WSS gradients were calculated using conventional techniques. Results: Implantation of a stent that causes straightening, rather than conforms to the natural curvature of the artery causes a reduction in the radius of curvature and subsequent increase in the Dean number within the stented region. This straightening leads to modest skewing of the velocity profile at the inlet and outlet of the stented region where alterations in indices of WSS are most pronounced. For example, time-averaged WSS in the proximal portion of the stent ranged from 8.91 to 11.7 dynes/cm2 along the pericardial luminal surface and 4.26 to 4.88 dynes/cm2 along the myocardial luminal surface of curved coronary arteries as compared to 8.31 dynes/cm2 observed throughout the stented region of a straight vessel implanted with an equivalent stent. Conclusion: The current results predicting large spatial and temporal variations in WSS at specific locations in curved arterial 3D CFD simulations are consistent with clinically observed sites of restenosis. If the findings of this idealized study translate to the clinical situation, the regional geometry established immediately after stent implantation may predispose portions of the stented vessel to a higher risk of neointimal hyperplasia and subsequent restenosis.

1 March 2005 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
JLJr. John F. LaDisa
Jr. John F. LaDisa
LOLars E. Olson
Lars E. Olson
IGIsmail Guler
Ismail Guler
DHDouglas A. Hettrick
Douglas A. Hettrick
JKJudy R. Kersten
Judy R. Kersten
PPPaul S. Pagel
Paul S. Pagel
The success of vascular stents in the restoration of blood flow is limited by restenosis. Recent data generated from computational fluid dynamics (CFD) models suggest that stent geometry may cause local alterations in wall shear stress (WSS) that have been associated with neointimal hyperplasia and subsequent restenosis. However, previous CFD studies have ignored histological evidence of vascular straightening between circumferential stent struts. We tested the hypothesis that consideration of stent-induced vascular deformation may more accurately predict alterations in indexes of WSS that may subsequently account for histological findings after stenting. We further tested the hypothesis that the severity of these alterations in WSS varies with the degree of vascular deformation after implantation. Steady-state and time-dependent simulations of three-dimensional CFD arteries based on canine coronary artery measurements of diameter and blood flow were conducted, and WSS and WSS gradients were calculated. Circumferential straightening introduced areas of high WSS between stent struts that were absent in stented vessels of circular cross section. The area of vessel exposed to low WSS was dependent on the degree of circumferential vascular deformation and axial location within the stent. Stents with four vs. eight struts increased the intrastrut area of low WSS in vessels, regardless of cross-sectional geometry. Elevated WSS gradients were also observed between struts in vessels with polygonal cross sections. The results obtained using three-dimensional CFD models suggest that changes in vascular geometry after stent implantation are important determinants of WSS distributions that may be associated with subsequent neointimal hyperplasia.

8 September 2011 in Acta Anaesthesiologica Scandinavica
Verified
Journal Article
Closed access
PDF file
PPPaul S. Pagel
Paul S. Pagel
JHJ. A. Hudetz
J. A. Hudetz