Haiyi Bian

Dr. Haiyi Bian

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2020 in Applied Optics
Verified
Journal Article
Closed access
PDF file
RJRendong Ji
Rendong Ji
SMShicai Ma
Shicai Ma
HYHua Yao
Hua Yao
YHYue Han
Yue Han
XYXiao Yang
Xiao Yang
HBHaiyi Bian
Haiyi Bian
Compared with high-performance liquid chromatography and mass spectroscopy, fluorescence spectroscopy has attracted considerable attention in the field of pesticide residue detection due to its practical advantages of providing rapid, simultaneous analysis and non-destructive detection. However, given that the concentration of pesticide residue detected via fluorescence spectroscopy is calculated in accordance with the Beer–Lambert law, this method can only detect samples containing a single kind of pesticide or several kinds of pesticides with completely different fluorescences. Multiple partial least-squares (PLS) models are introduced in this work to overcome this disadvantage and achieve the concentration of zhongshengmycin, paclobutrazol, boscalid, and pyridaben, whose fluorescences are overlapping. The R squares of the models for zhongshengmycin, paclobutrazol, boscalid, and pyridaben were 0.9942, 0.9912, 0.9913, and 0.9847, respectively. Results indicated that fluorescence spectroscopy combined with multiple PLS models can be used to detect multiple kinds of pesticides in the water.

21 September 2017 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
HBHaiyi Bian
Haiyi Bian
PWPeng Wang
Peng Wang
JWJun Wang
Jun Wang
HYHuancai Yin
Huancai Yin
YTYubing Tian
Yubing Tian
JGJing Gao
Jing Gao
We report a self-reference algorithm to discriminate human and nonhuman blood by calculating the ratios of identification Raman peaks to reference Raman peaks and choosing appropriate threshold values. The influence of using different reference peaks and identification peaks was analyzed in detail. The Raman peak at 1003 cm−1 was proved to be a stable reference peak to avoid the influencing factors, such as the incident laser intensity and the amount of sample. The Raman peak at 1341 cm−1 was found to be an efficient identification peak, which indicates that the difference between human and nonhuman blood results from the C–H bend in tryptophan. The comparison between self-reference algorithm and partial least square method was made. It was found that the self-reference algorithm not only obtained the discrimination results with the same accuracy, but also provided information on the difference of chemical composition. In addition, the performance of self-reference algorithm whose true positive rate is 100% is significant for customs inspection to avoid genetic disclosure and forensic science.

5 July 2018 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
HBHaiyi Bian
Haiyi Bian
PWPeng Wang
Peng Wang
NWNing Wang
Ning Wang
YTYubing Tian
Yubing Tian
PBPengli Bai
Pengli Bai
JGJing Gao
Jing Gao
The discrimination accuracy for human and nonhuman blood is important for customs inspection and forensic applications. Recently, Raman spectroscopy has shown effectiveness in analyzing blood droplets and stains with an excitation wavelength of 785 nm. However, the discrimination of liquid whole blood in a vacuum blood tube using Raman spectroscopy, which is a form of noncontact and nondestructive detection, has not been achieved. An excitation wavelength of 532 nm was chosen to avoid the fluorescent background of the blood tube, at the cost of reduced spectroscopic information and discrimination accuracy. To improve the accuracy and true positive rate (TPR) for human blood, a dual-model analysis method is proposed. First, model 1 was used to discriminate human-unlike nonhuman blood. Model 2 was then used to discriminate human-like nonhuman blood from the “human blood” obtained by model 1. A total of 332 Raman spectra from 10 species were used to build and validate the model. A blind test and external validation demonstrated the effectiveness of the model. Compared with the results obtained by the single partial least-squares model, the discrimination performance was improved. The total accuracy and TPR, which are highly important for practical applications, increased to 99.1% and 97.4% from 87.2% and 90.6%, respectively.

20 March 2018 in Optics Express
Verified
Journal Article
Open access
PDF file
HBHaiyi Bian
Haiyi Bian
JGJing Gao
Jing Gao
Raman spectroscopy paired with the partial least squares (PLS) method is commonly used for quantitative or qualitative analysis of complex samples. However, spectral shift induced by different Raman spectroscopy, different environment or different measured time will decrease the accuracy of the PLS model. In this work, the processing algorithms that improve the accuracy by removing the noise, background and varying sources of other spectral interference were first reviewed. The error induced by the spectral shift was analyzed and the formulas of the error were derived. The formulas were then used to calculate the theoretical error in the example of discriminating human and nonhuman blood. A comparison of the actual errors obtained from the mathematical method and experiment with the theoretical value demonstrated the effectiveness of the equation. The compensation for nonhuman blood according to the average error demonstrated the improvement of the accuracy. Finally, the non-uniform sampling of the Raman shift by charge-coupled device (CCD) was considered in the error equation. An accurate error equation was obtained. This work could help improve the stability of PLS models in the case of the spectral shift of the spectrometer in Raman spectroscopy.

9 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
YWYawen Wu Yawen Wu
Yawen Wu Yawen Wu
SJSABA JASIM
SABA JASIM
Dhiya  Al-JumeilyDhiya Al-Jumeily
Dhiya Al-Jumeily
HBHaiyi Bian
Haiyi Bian
This paper’s novel focus is predicting the leaf nitrogen content of rice during growing and maturing. A multispectral image processing-based prediction model of the Radial Basis Function Neural Network (RBFNN) model was proposed. Moreover, this paper depicted three primary points as the following: First, collect images of rice leaves (RL) from a controlled condition experimental laboratory and new shoot leaves in different stages in the visible light spectrum, and apply digital image processing technology to extract the color characteristics of RL and the morphological characteristics of the new shoot leaves. Secondly, the RBFNN model, the General Regression Model (GRL), and the General Regression Method (GRM) model were constructed based on the extracted image feature parameters and the nitrogen content of rice leaves. Third, the RBFNN is optimized by and Partial Least-Squares Regression (RBFNN-PLSR) model. Finally, the validation results show that the nitrogen content prediction models at growing and mature stages that the mean absolute error (MAE), the Mean Absolute Percentage Error (MAPE), and the Root Mean Square Error (RMSE) of the RFBNN model during the rice-growing stage and the mature stage are 0.6418 (%), 0.5399 (%), 0.0652 (%), and 0.3540 (%), 0.1566 (%), 0.0214 (%) respectively, the predicted value of the model fits well with the actual value. Finally, the model may be used to give the best foundation for achieving exact fertilization control by continuously monitoring the nitrogen nutrition status of rice. In addition, at the growing stage, the RBFNN model shows better results compared to both GRL and GRM, in which MAE is reduced by 0.2233% and 0.2785%, respectively.

30 January 2019 in Optics Express
Verified
Journal Article
Closed access
PDF file
HBHaiyi Bian
Haiyi Bian
YZY. L. Zhang
Y. L. Zhang
WGWanrong Gao
Wanrong Gao
JGJing Gao
Jing Gao
Developments in analytical chemistry technology, especially the combination between the partial least squares and spectroscopy, have contributed significantly to predicting the chemical concentrations and discriminating similar chemical analytes. However, spectral shift is an unwanted but inevitable factor for the spectroscopic analyzer, especially in practical application, which decreases the method’s accuracy and stability. To remove the term of spectral shift completely and increase the robustness of spectroscopic analysis method, Fourier transform based partial least squares method was proposed. The approach used Fourier transform first to transform the spectral shift in the “time domain” to the phase term in the “frequency domain.” The module of the Fourier transformed spectra was then calculated. As a result, the phase term was removed (the module of the phase term is 1), which means the spectral shift term was removed completely. Finally, the spectra modules were used to build the model and validate. The approach’s advantages are: (i) that the approach provides a new insight to treat the spectral shift in spectroscopic analyzer; (ii) that the model is insensitive to spectral shift; (iii) that the approach makes partial least squares combined with spectroscopy more suitable for practical application, rather than lab experiment, because spectral shift is permitted, which means the decreased requirements of measure environment. As an example, blood species discrimination, using Raman spectroscopy, was used in order to demonstrate this approach’s effectiveness.