Árpád Farkas

Dr. Árpád Farkas

Centre for Energy Research

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2021 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
PPPetra Party
Petra Party
CBCsilla Balla-Bartos
Csilla Balla-Bartos
ÁFÁrpád Farkas
Árpád Farkas
PSPiroska Szabó-Révész
Piroska Szabó-Révész
Rita AmbrusRita Ambrus
Rita Ambrus
Pulmonary delivery has high bioavailability, a large surface area for absorption, and limited drug degradation. Particle engineering is important to develop inhalable formulations to improve the therapeutic effect. In our work, the poorly water-soluble meloxicam (MX) was used as an active ingredient, which could be useful for the treatment of non-small cell lung cancer, cystic fibrosis, and chronic obstructive pulmonary disease. We aimed to produce inhalable “nano-in-micro” dry powder inhalers (DPIs) containing MX and additives (poly-vinyl-alcohol, leucine). We targeted the respiratory zone with the microcomposites and reached a higher drug concentration with the nanonized active ingredient. We did the following investigations: particle size analysis, morphology, density, interparticular interactions, crystallinity, in vitro dissolution, in vitro permeability, in vitro aerodynamics (Andersen cascade impactor), and in silico aerodynamics (stochastic lung model). We worked out a preparation method by combining wet milling and spray-drying. We produced spherical, 3–4 µm sized particles built up by MX nanoparticles. The increased surface area and amorphization improved the dissolution and diffusion of the MX. The formulations showed appropriate aerodynamical properties: 1.5–2.4 µm MMAD and 72–76% fine particle fraction (FPF) values. The in silico measurements proved the deposition in the deeper airways. The samples were suitable for the treatment of local lung diseases.

1 October 2016 in European Journal of Pharmaceutical Sciences
Verified
Journal Article
Closed access
ÁFÁrpád Farkas
Árpád Farkas
ÁJÁgnes Jókay
Ágnes Jókay
IBImre Balásházy
Imre Balásházy
PFPéter Füri
Péter Füri
VMVeronika Müller
Veronika Müller
AHAlpár Horváth
Alpár Horváth

10 June 2020 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
EBEdit Benke
Edit Benke
ÁFÁrpád Farkas
Árpád Farkas
PSPiroska Szabó-Révész
Piroska Szabó-Révész
Rita AmbrusRita Ambrus
Rita Ambrus
Most of the marketed dry powder inhalation (DPI) products are traditional, carrier-based formulations with low drug concentrations deposited in the lung. However, due to their advantageous properties, their development has become justified. In our present work, we developed an innovative, carrier-based DPI system, which is an interactive physical blend of a surface-modified carrier and a spray-dried drug with suitable shape and size for pulmonary application. Meloxicam potassium, a nonsteroidal anti-inflammatory drug (NSAID), was used as an active ingredient due to its local anti-inflammatory effect and ability to decrease the progression of cystic fibrosis (CF) and chronic obstructive pulmonary disease (COPD). The results of the in vitro and in silico investigations showed high lung deposition in the case of this new formulation, confirming that the interparticle interactions were changed favorably.

1 November 2020 in European Journal of Pharmaceutical Sciences
Verified
Journal Article
Open access
AHAlpár Horváth
Alpár Horváth
ÁFÁrpád Farkas
Árpád Farkas
ASAnnamária Szipőcs
Annamária Szipőcs
GTGábor Tomisa
Gábor Tomisa
ZSZsuzsanna Szalai
Zsuzsanna Szalai
GGGabriella Gálffy
Gabriella Gálffy
The effect of breathing parameters on the airway deposition of the inhaled aerosols with known size was intensively studied in the literature. However, in the case of dry powder aerosol drugs both the quantity and quality of the particles emitted by the inhaler and inhaled by the patients is a complex function of the patient's breathing parameters, which in turn depend also on the disease severity and current status of the patient. The aim of this study was to evaluate the impact of breathing parameters, gender, age, symptoms and exacerbation history related disease severity (GOLD groups) of chronic obstructive pulmonary disease (COPD) patients on the lung dose of four different drugs emitted by three DPIs (dry powder inhalers). Breathing profiles of 47 COPD patients were recorded while they inhaled through Turbuhaler®, Breezhaler® and Genuair® inhalers. Patient specific emitted doses and particle size distributions were determined for Symbicort® Turbuhaler®, Onbrez® Breezhaler®, Seebri® Breezhaler® and Bretaris® Genuair® aerosol drugs. Airway deposition was quantified by a validated whole respiratory tract particle deposition model. Correlation analysis of the lung doses with breathing parameters through the devices and with standard spirometric parameters was performed. The effects of gender, age and degree of disease severity (GOLD groups) on the lung doses were also studied by statistical analysis. Mean values and distributions of the deposited lung doses proved to be both drug and device specific, yielding 24.2 (±7.8), 22.6 (±3.6), 34.2 (±4.8) and 23.9 (±5.4) % values for Symbicort®, Onbrez®, Seebri® and Bretaris®, respectively. Drugs with flow rate sensitive emitted dose and emitted particle size distribution exhibited higher intersubject variability of the lung doses. The degree of correlation of lung doses with breathing parameters through the devices was also drug specific. Correlation with flow rate was the strongest for Symbicort® Turbuhaler®. Longer breath-hold increased the lung dose of all the studied drugs. Correlations of lung dose with standard spirometric parameters was generally weaker than its correlation with the parameters measured when inhaling through the devices. Men had higher lung deposition than women, younger patients had higher deposition than older ones and patients with less severe disease higher doses than those with more severe COPD, but the differences were statistically significant only upon gender and only in case of Symbicort® and Seebri®. Patients with better inhalation parameters are likely to have higher lung deposition when inhaling a drug with emitted dose and particle size distribution sensitive to the inhalation flow rate. At the same time, patients with lower lung capacity show better deposition results when inhaling from inhalers emitting a more constant amount of drug and particles with more stable aerodynamic characteristics. A more powerful inhalation significantly increases the lung dose for the drug emitted by Turbuhaler®, while long breath-hold is likely to yield significantly higher deposition for drugs emitted by Breezhaler® and Genuair®. Lung doses of two different drugs dispensed in the same inhaler can be significantly different.

1 November 2017 in International Journal of Pharmaceutics
Verified
Journal Article
Open access
ÁFÁrpád Farkas
Árpád Farkas
DLDavid Lewis
David Lewis
TCTanya Church
Tanya Church
ATAlan Tweedie
Alan Tweedie
FMFrancesca Mason
Francesca Mason
IBImre Balásházy
Imre Balásházy
The breath-actuated mechanism (BAM) is a mechanical unit included in NEXThaler® with the role of delaying the emission of the drug until the inhalation flow rate of the patient is sufficiently high to detach the drug particles from their carriers. The main objective of this work was to analyse the effect of the presence of BAM on the size distribution of the emitted drug and its airway deposition efficiency and distribution. Study of the hygroscopic growth of the emitted drug particles and its effect on the deposition was another goal of this study. Size distributions of Foster® NEXThaler® drug particles emitted by dry powder inhalers with and without BAM have been measured by a Next Generation Impactor. Three characteristic inhalation profiles of asthmatic patients (low, moderate and high flow rates) were used for both experimental and modelling purposes. Particle hygroscopic growth was determined by a new method, where experimental measurements are combined with simulations. Upper airway and lung deposition fractions were computed assuming 5s and 10s breath-hold times. By the inclusion of BAM the fine particle fraction of the steroid component increased from 24 to 30% to 47-51%, while that of bronchodilator from 25-34% to 52-55%. The predicted upper airway steroid and bronchodilator doses decreased from about 60% to 35-40% due to BAM. At the same time, predicted lung doses increased from about 20%-35% (steroid) and from 22% to 38% (bronchodilator) for the moderate flow profile and from about 25% to 40% (steroid) and from 29% to 47% (bronchodilator) for the high inhalation flow profile. Although BDP and FF upper airway doses decreased by a factor of about two when BAM was present, lung doses of both components were about the same in the BAM and no-BAM configurations at the weakest flow profile. However, lung dose increased by 2-3% even for this profile when hygroscopic growth was taken into account. In conclusion, the NEXThaler® BAM mechanism is a unique feature enabling high emitted fine particle fraction and enhanced drug delivery to the lungs.

1 April 2019 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
ÁFÁrpád Farkas
Árpád Farkas
FLFrantisek Lizal
Frantisek Lizal
Jan JedelskyJan Jedelsky
Jan Jedelsky
JEJakub Elcner
Jakub Elcner
AHAlpár Horváth
Alpár Horváth
MJMiroslav Jicha
Miroslav Jicha
Medical aerosols are key elements of current chronic obstructive pulmonary disease (COPD) therapy. Therapeutic effects are conditioned by the delivery of the right amount of medication to the right place within the airways, that is, to the drug receptors. Deposition of the inhaled drugs is sensitive to the breathing pattern of the patients which is also connected with the patient’s disease severity. The objective of this work was to measure the realistic inhalation profiles of mild, moderate, and severe COPD patients, simulate the deposition patterns of Symbicort® Turbuhaler® dry powder drug and compare them to similar patterns of healthy control subjects. For this purpose, a stochastic airway deposition model has been applied. Our results revealed that the amount of drug depositing within the lungs correlated with the degree of disease severity. While drug deposition fraction in the lungs of mild COPD patients compared with that of healthy subjects (28% versus 31%), lung deposition fraction characteristic of severe COPD patients was lower by a factor of almost two (about 17%). Deposition fraction of moderate COPD patients was in-between (23%). This implies that for the same inhaler dosage severe COPD patients receive a significantly lower lung dose, although, they would need more.