Bilirubin originates from hemoglobin metabolism and is an important biomarker for liver function. A ratiometric film sensor based on gold nanoclusters (AuNCs) was fabricated for highly sensitive determination of free bilirubin (fBR). Using bovine serum albumin (BSA) as a template, AuNCs that can emit blue and red fluorescence were prepared by the hydrothermal method at different pH values. Two kinds of AuNCs were incorporated into a single film by the layer-by-layer assembly (LBL) technique. The obtained thin-film showed dual fluorescence peaks excited at 372 nm, corresponding to the blue (443 nm) and red (622 nm) emissions of AuNCs respectively. When fBR interacted with the film, both fluorescence peaks were quenched at different degrees. A ratiometric method for fBR detection was established based on the fluorescence intensity ratio of the two emissions. The linear calibration curve for fBR lay in the concentration range of 0.01–2.00 μmol L−1 with a detection limit of 8.90 ± 0.34 nmol L−1 (S/N = 3). The film sensor showed a quick and sensitive response to fBR and could detect fBR in real samples with satisfactory results.
Serum bilirubin is an important biomarker for the diagnosis of various types of liver diseases and blood disorders. A polydopamine/gold nanoclusters composite film was fabricated for the fluorescent sensing of free bilirubin. Bovine serum albumin (BSA)-stabilized gold nanoclusters (AuNCs) were used as probes for biorecognition. The polydopamine film was utilized as an adhesion layer for immobilization of AuNCs. When the composite film was exposed to free bilirubin, due to the complex that was formed between BSA and free bilirubin, the fluorescence intensity of the composite film was gradually weakened as the bilirubin concentration increased. The fluorescence quenching ratio (F0/F) was linearly proportional to free bilirubin over the concentration range of 0.8~50 μmol/L with a limit of detection of 0.61 ± 0.12 μmol/L (S/N = 3). The response was quick, the film was recyclable, and common ingredients in human serum did not interfere with the detection of free bilirubin.
8 May 2023 in Analytical and Bioanalytical Chemistry
As an essential indicator of liver function, bilirubin is of great significance for clinical diagnosis. A non-enzymatic sensor has been established for sensitive bilirubin detection based on the bilirubin oxidation catalyzed by unlabeled gold nanocages (GNCs). GNCs with dual-localized surface plasmon resonance (LSPR) peaks were prepared by a one-pot method. One peak around 500 nm was ascribed to gold nanoparticles (AuNPs), and the other located in the near-infrared region was the typical peak of GNCs. The catalytic oxidation of bilirubin by GNCs was accompanied by the disruption of cage structure, releasing free AuNPs from the nanocage. This transformation changed the dual peak intensities in opposite trend, and made it possible to realize the colorimetric sensing of bilirubin in a ratiometric mode. The absorbance ratios showed good linearity to bilirubin concentrations in the range of 0.20~3.60 μmol/L with a detection limit of 39.35 nM (3σ, n = 3). The sensor exhibited excellent selectivity for bilirubin over other coexisting substances. Bilirubin in real human serum samples was detected with recoveries ranging from 94.5 to 102.6%. The method for bilirubin assay is simple, sensitive and without complex biolabeling.