Mukhtiar Memon

Dr. Mukhtiar Memon


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2014 in Sensors
Verified
Journal Article
Open access
PDF file
MMMukhtiar Memon
Mukhtiar Memon
SWStefan Wagner
Stefan Wagner
CPChristian Fischer Pedersen
Christian Fischer Pedersen
FBFemina Hassan Aysha Beevi
Femina Hassan Aysha Beevi
FHFinn Overgaard Hansen
Finn Overgaard Hansen
Ambient Assisted Living (AAL) is an emerging multi-disciplinary field aiming at exploiting information and communication technologies in personal healthcare and telehealth systems for countering the effects of growing elderly population. AAL systems are developed for personalized, adaptive, and anticipatory requirements, necessitating high quality-of-service to achieve interoperability, usability, security, and accuracy. The aim of this paper is to provide a comprehensive review of the AAL field with a focus on healthcare frameworks, platforms, standards, and quality attributes. To achieve this, we conducted a literature survey of state-of-the-art AAL frameworks, systems and platforms to identify the essential aspects of AAL systems and investigate the critical issues from the design, technology, quality-of-service, and user experience perspectives. In addition, we conducted an email-based survey for collecting usage data and current status of contemporary AAL systems. We found that most AAL systems are confined to a limited set of features ignoring many of the essential AAL system aspects. Standards and technologies are used in a limited and isolated manner, while quality attributes are often addressed insufficiently. In conclusion, we found that more inter-organizational collaboration, user-centered studies, increased standardization efforts, and a focus on open systems is needed to achieve more interoperable and synergetic AAL solutions.

8 December 2016 in Sensors
Verified
Journal Article
Open access
PDF file
JMJorge Miguel Miranda
Jorge Miguel Miranda
Jorge CabralJorge Cabral
Jorge Cabral
SWStefan Wagner
Stefan Wagner
CPChristian Fischer Pedersen
Christian Fischer Pedersen
BRBlaise Ravelo
Blaise Ravelo
MMMorten Mathiesen
Morten Mathiesen
Population aging and increasing pressure on health systems are two issues that demand solutions. Involving and empowering citizens as active managers of their health represents a desirable shift from the current culture mainly focused on treatment of disease, to one also focused on continuous health management and well-being. Current developments in technological areas such as the Internet of Things (IoT), lead to new technological solutions that can aid this shift in the healthcare sector. This study presents the design, development, implementation and evaluation of a platform called Common Recognition and Identification Platform (CRIP), a part of the CareStore project, which aims at supporting caregivers and citizens to manage health routines in a seamless way. Specifically, the CRIP offers sensor-based support for seamless identification of users and health devices. A set of initial requirements was defined with a focus on usability limitations and current sensor technologies. The CRIP was designed and implemented using several technologies that enable seamless integration and interaction of sensors and people, namely Near Field Communication and fingerprint biometrics for identification and authentication, Bluetooth for communication with health devices and web services for wider integration with other platforms. Two CRIP prototypes were implemented and evaluated in laboratory during a period of eight months. The evaluations consisted of identifying users and devices, as well as seamlessly configure and acquire vital data from the last. Also, the entire Carestore platform was deployed in a nursing home where its usability was evaluated with caregivers. The evaluations helped assess that seamless identification of users and seamless configuration and communication with health devices is feasible and can help enable the IoT on healthcare applications. Therefore, the CRIP and similar platforms could be transformed into a valuable enabling technology for secure and reliable IoT deployments on the healthcare sector.

7 February 2017 in IEEE Microwave Magazine
Verified
Journal Article
Closed access
JMJorge Miguel Miranda
Jorge Miguel Miranda
MMMukhtiar Memon
Mukhtiar Memon
Jorge CabralJorge Cabral
Jorge Cabral
BRBlaise Ravelo
Blaise Ravelo
SWStefan Wagner
Stefan Wagner
CNClaus Nielsen
Claus Nielsen
Wireless technologies are currently among the most prominent candidates for use by the medical and care-giving community as a part of the development of telemedicine systems. The exponential progress of these technologies is expected to open a multitude of opportunities and choices for enhanced patient safety, better data collection, increased convenience for patients, and reduced costs for health systems. Thanks to the cost effectiveness and clinical acceptability of wireless telecommunication technology, patient diagnosis and treatment have been significantly improved. Technology for remote sensing of patients' activity is also being developed.

12 August 2008
Verified
Book Chapter
Closed access
PDF file
MHMichael Hafner
Michael Hafner
MMMukhtiar Memon
Mukhtiar Memon
MAMuhammad Alam
Muhammad Alam

7 January 2015 in The European Physical Journal Applied Physics
Verified
Journal Article
Closed access
PDF file
JMJorge Miguel Miranda
Jorge Miguel Miranda
Jorge CabralJorge Cabral
Jorge Cabral
BRBlaise Ravelo
Blaise Ravelo
SWStefan Wagner
Stefan Wagner
CPChristian F. Pedersen
Christian F. Pedersen
MMMorten Mathiesen
Morten Mathiesen
An innovative e-healthcare platform named common recognition and identification platform (CRIP) was developed and tested as part of the CareStore project. CareStore and CRIP aims at delivering accurate and safe disease management by minimising human operator errors in hospitals and care facilities. To support this, the CRIP platform features fingerprint biometrics and near field communication (NFC) for user identification; and Bluetooth communication support for a range of telemedicine medical devices adhering to the IEEE 11073 standard. The aim of this study was to evaluate the electromagnetic compatibility (EMC) immunity of the CRIP platform in order to validate it for medical application use. The first prototype of CRIP was demonstrated to operate as expected by showing the user identification function feasibility, both via NFC and biometric, and by detection of Bluetooth devices via radio frequency (RF) scanning. The NFC module works in the 13.56 MHz band and the Bluetooth module work in the 2.4 GHz band, according to the IEEE 802.15.1 standard. The standard test qualification of the CRIP was performed based on the radiated EMC immunity with respect to the EN 61000-4-3 standard. The immunity tests were conducted under industrial EMC compliance with electric field aggression, with levels up to 10 V/m in both horizontal and vertical polarisations when the test antenna and the CRIP were placed at a distance of 3 m. It was found that the CRIP device complies with the European electromagnetic (EM) radiation immunity requirements.

15 August 2012 in Software and Systems Modeling
Verified
Journal Article
Closed access
PDF file
MMMukhtiar Memon
Mukhtiar Memon
GMGordhan D. Menghwar
Gordhan D. Menghwar
MHMansoor Hyder
Mansoor Hyder
AJAkhtar Ali Jalbani
Akhtar Ali Jalbani
WMWaqar Mehmood
Waqar Mehmood