We present the design and validation of a low-cost, customizable and 3D-printed anthropomorphic soft robotic hand exoskeleton for rehabilitation of hand injuries using remotely administered physical therapy regimens. The design builds upon previous work done on cable actuated exoskeleton designs by implementing the same kinematic functionality, but with the focus shifted to ease of assembly and cost effectiveness as to allow patients and physicians to manufacture and assemble the hardware necessary to implement treatment. The exoskeleton was constructed solely from 3D-printed and widely available off-the-shelf components. Control of the actuators was realized using an Arduino microcontroller, with a custom-designed shield to facilitate ease of wiring. Tests were conducted to verify that the range of motion of the digits and the forces exerted at the fingertip coincided with those of a healthy human hand.
The increasing incidence of head and neck cancers in South Asia has been described as a global health crisis.1 Particularly in India, the high incidence of oral cancers is ascribed to the popularity of chewing “gutka” (a compound mixture of tobacco, acacia, and betel nut extracts). The problem of high oral cancer incidence is exacerbated, particularly in rural areas, by limited accessibility of early stage medical screening and imaging. Furthermore, the economic burden of late stage treatments such as complex surgical procedures and/or radiation therapy pose a further barrier in oral cancer management.2 Photodynamic therapy (PDT) has emerged as an alternative and noninvasive early stage anticancer treatment modality.3 PDT is a treatment in which a precursor or photosensitizer drug localized to the lesion sites is activated by light to generate singlet oxygen ()-mediated photocytotoxicity against cancer cells. Here, we used 5-aminolevulinic acid (ALA as Levulan®, DUSA, SUN Pharmaceuticals, Inc.), a precursor for the photoactive derivative protoporphyrin IX (PpIX).4 PpIX not only acts as a fluorescent probe but also imparts antitumor toxicity when activated by light. This dual functionality has been used successfully for image-guided treatment of various cancers, including those of the oral cavity.5,6 In clinical settings, PpIX fluorescence and photobleaching make it effective as a diagnostic as well as a treatment monitoring tool.7,8 Recently, a smartphone with fluorescence imaging capability has been used as a low-cost device for premalignant oral screening.8 The wide availability and popularity of smartphones, particularly in the developing countries, make this device promising as a low-cost, portable, and capable theragnostic cancer technology for global health.9–11 Building on previous preliminary findings,12 we report here an evaluation of this simple and low-cost fluorescence imaging approach for guidance and monitoring of PDT treatment in the clinic.
Oral cancer prevalence is increasing at an alarming rate worldwide, especially in developing countries which lack the medical infrastructure to manage it. For example, the oral cancer burden in India has been identified as a public health crisis. The high expense and logistical barriers to obtaining treatment with surgery, radiotherapy and chemotherapy often result in progression to unmanageable late stage disease with high morbidity. Even when curative, these approaches can be cosmetically and functionally disfiguring with extensive side effects. An alternate effective therapy for oral cancer is a light based spatially-targeted cytotoxic therapy called photodynamic therapy (PDT). Despite excellent healing of the oral mucosa in PDT, a lack of robust enabling technology for intraoral light delivery has limited its broader implementation. Leveraging advances in 3D printing, we have developed an intraoral light delivery system consisting of modular 3D printed light applicators with pre-calibrated dosimetry and mouth props that can be utilized to perform PDT in conscious subjects without the need of extensive infrastructure or manual positioning of an optical fiber. To evaluate the stability of the light applicators, we utilized an endoscope in lieu of the optical fiber to monitor motion in the fiducial markers. Here we showcase the stability (less than 2 mm deviation in both horizontal and vertical axis) and ergonomics of our applicators in delivering light precisely to the target location in ten healthy volunteers. We also demonstrate in five subjects with T1N0M0 oral lesions that our applicators coupled with a low-cost fiber coupled LED-based light source served as a complete platform for intraoral light delivery achieving complete tumor response with no residual disease at initial histopathology follow up in these patients. Overall, our approach potentiates PDT as a viable therapeutic option for early stage oral lesions that can be delivered in low resource settings.
Brain/Body Computer Interface (BBCI) technology facilitates research in human cognition and assistive technologies. BBCI acquires and analyzes physiological signals from human body/brain such as electroencephalography (EEG) to observe human physiological states and potentially enable external control. BBCI devices require accurate data acquisition systems with sufficient dynamic range for various brain/body signals. Also, embedded processing is desirable for real-time interaction and flexible deployment. However, most off-the-shelf BBCI devices are very costly, e.g. g.USBamp at $15K and do not offer embedded processing. Hence, an open embedded device for BBCI acquisition and processing is needed to foster the BBCI research. This paper proposes EEGu2 as a portable embedded BBCI device. Based on a BeagleBone Black (BBB), EEGu2 integrates a custom-designed cape including 2 PCBs: an acquisition board for 16-channel 24-bit acquisition up to 1KHz sampling frequency and a power board for wall charging and powering mobile operations. EEGu2 measurement shows a high acquisition accuracy with 25dB signal-to-noise ratio and 0.785μV peak-to-peak input referred noise. At maximum performance, the cape consumes 101.2 mW while BBB consumes 1850 mW. With two lithium batteries, EEGu2 operates independently 12 hours. We demonstrate the flexibility and portability of EEGu2 in the context of Human-in-the-Loop Cyber-Physical Systems (HiLCPS) that augments human interaction with physical world through BBCI. The EEGu2 firmware is integrated into the HiLCPS Framework to enable the location transparent access via the MATLAB interface. EEGu2 empowers rapid embedded BBCI application deployment and we show the flexibility of EEGu2 with a BCI Speller application that acquires real-time EEG signals and infers the user spelling based on Steady State Visually Evoked Potential.
13 January 2020 in Industrial Robot: the international journal of robotics research and application
Purpose: This paper aims to present an intuitive control system for robotic manipulators that pairs a Leap Motion, a low-cost optical tracking and gesture recognition device, with the ability to record and replay trajectories and operation to create an intuitive method of controlling and programming a robotic manipulator. This system was designed to be extensible and includes modules and methods for obstacle detection and dynamic trajectory modification for obstacle avoidance. Design/methodology/approach: The presented control architecture, while portable to any robotic platform, was designed to actuate a six degree-of-freedom robotic manipulator of our own design. From the data collected by the Leap Motion, the manipulator was controlled by mapping the position and orientation of the human hand to values in the joint space of the robot. Additional recording and playback functionality was implemented to allow for the robot to repeat the desired tasks once the task had been demonstrated and recorded. Findings: Experiments were conducted on our custom-built robotic manipulator by first using a simulation model to characterize and quantify the robot’s tracking of the Leap Motion generated trajectory. Tests were conducted in the Gazebo simulation software in conjunction with Robot Operating System, where results were collected by recording both the real-time input from the Leap Motion sensor, and the corresponding pose data. The results of these experiments show that the goal of accurate and real-time control of the robot was achieved and validated our methods of transcribing, recording and repeating six degree-of-freedom trajectories from the Leap Motion camera. Originality/value: As robots evolve in complexity, the methods of programming them need to evolve to become more intuitive. Humans instinctively teach by demonstrating the task to a given subject, who then observes the various poses and tries to replicate the motions. This work aims to integrate the natural human teaching methods into robotics programming through an intuitive, demonstration-based programming method.