Zhonghua Sun

Prof. Dr. Zhonghua Sun

Curtin University
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2018 in BMC Neurology
Verified
Journal Article
Open access
PDF file
YSYanguang Shen
Yanguang Shen
YZYan Zhong
Yan Zhong
HWHaiyi Wang
Haiyi Wang
LMLu Ma
Lu Ma
YWYingwei Wang
Yingwei Wang
HYHuiyi Ye
Huiyi Ye
To determine whether MRI feature analysis can differentiate benign retroperitoneal extra-adrenal paragangliomas and schwannomas. The MRI features of 50 patients with confirmed benign retroperitoneal extra-adrenal paragangliomas and schwannomas were retrospectively reviewed by two radiologists blinded to the histopathologic diagnosis. These features were compared between two types of tumours by use of the Mann-Whitney test and binary logistic regression. The patients’ clinical characteristics were reviewed. Analysis of MRI images from 50 patients revealed no significant differences in the quantitative MRI features of lesion size, ratio of diameter and apparent diffusion coefficient. There were significant differences in the qualitative MRI features of location, necrosis, cysts and degree of tumour enhancement for two readers, with no significant differences in the other qualitative MRI features between these tumours. The combination of necrosis with degree of tumour enhancement during the arterial phase increased the probability that a retroperitoneal mass would represent retroperitoneal extra-adrenal paraganglioma as opposed to schwannoma. We have presented the largest series of MRI features of both benign retroperitoneal extra-adrenal paragangliomas and schwannomas. Some MRI features assist in the differentiation between these tumours, with imaging features consisting of necrosis and avid enhancement during the arterial phase, suggestive of retroperitoneal extra-adrenal paragangliomas.

1 May 2012 in British Journal of Radiology
Verified
Journal Article
Open access
PDF file
Zhonghua SunZhonghua Sun
Zhonghua Sun
GCG H Choo
G H Choo
KNK H Ng
K H Ng
Coronary CT angiography has been increasingly used in the diagnosis of coronary artery disease owing to rapid technological developments, which are reflected in the improved spatial and temporal resolution of the images. High diagnostic accuracy has been achieved with multislice CT scanners (64 slice and higher), and in selected patients coronary CT angiography is regarded as a reliable alternative to invasive coronary angiography. With high-quality coronary CT imaging increasingly being performed, patients can benefit from an imaging modality that provides a rapid and accurate diagnosis while avoiding an invasive procedure. Despite the tremendous contributions of coronary CT angiography to cardiac imaging, study results reported in the literature should be interpreted with caution as there are some limitations existing within the study design or related to patient risk factors. In addition, some attention must be given to the potential health risks associated with the ionising radiation received during cardiac CT examinations. Radiation dose associated with coronary CT angiography has raised serious concerns in the literature, as the risk of developing malignancy is not negligible. Various dose-saving strategies have been implemented, with some of the strategies resulting in significant dose reduction. The aim of this review is to present an overview of the role of coronary CT angiography on cardiac imaging, with focus on coronary artery disease in terms of the diagnostic and prognostic value of coronary CT angiography. Various approaches for dose reduction commonly recommended in the literature are discussed. Limitations of coronary CT angiography are identified. Finally, future directions and challenges with the use of coronary CT angiography are highlighted.

1 May 2020 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
Zhonghua SunZhonghua Sun
Zhonghua Sun
NZNan Zhang
Nan Zhang
YLYu Li
Yu Li
XXXunhua Xu
Xunhua Xu
Chest computed tomography (CT) is frequently used in diagnosing coronavirus disease 2019 (COVID-19) for detecting abnormal changes in the lungs and monitoring disease progression during the treatment process. Furthermore, CT imaging appearances are correlated with patients presenting with different clinical scenarios, such as early versus advanced stages, asymptomatic versus symptomatic patients, and severe versus nonsevere situations. However, its role as a screening and diagnostic tool in COVID-19 remains to be clarified. This article provides a systematic review and meta-analysis of the current literature on chest CT imaging findings with the aim of highlighting the contribution and judicious use of CT in the diagnosis of COVID-19. A search of PubMed/Medline, Web of Science, ScienceDirect, Google Scholar and Scopus was performed to identify studies reporting chest imaging findings in COVID-19. Chest imaging abnormalities associated with COVID-19 were extracted from the eligible studies and diagnostic value of CT in detecting these abnormal changes was compared between studies consisting of both COVID-19 and non-COVID-19 patients. A random-effects model was used to perform meta-analysis for calculation of pooled mean values and 95% confidence intervals (95% CI) of abnormal imaging findings. Fifty-five studies met the selection criteria and were included in the analysis. Pulmonary lesions more often involved bilateral lungs (78%, 95% CI: 45–100%) and were more likely to have a peripheral (65.35%, 95% CI: 25.93–100%) and peripheral plus central distribution (31.12%, 95% CI: 1.96–74.07%), but less likely to have a central distribution (3.57%, 95% CI: 0.99–9.80%). Ground glass opacities (GGO) (58.05%, 95% CI: 16.67–100%), consolidation (44.18%, 95% CI: 1.61–71.46%) and GGO plus consolidation (52.99%, 95% CI: 19.05–76.79%) were the most common findings reported in 94.5% (52/55) of the studies, followed by air bronchogram (42.50%, 95% CI: 7.78–80.39%), linear opacities (41.29%, 95% CI: 7.44–65.06%), crazy-paving pattern (23.57%, 95% CI: 3.13–91.67%) and interlobular septal thickening (22.91%, 95% CI: 0.90–80.49%). CT has low specificity in differentiating pneumonia-related lung changes due to significant overlap between COVID-19 and non-COVID-19 patients with no significant differences in most of the imaging findings between these two groups (P>0.05). Furthermore, normal CT (13.31%, 95% CI: 0.74–38.36%) was reported in 26 (47.3%) studies. Despite widespread use of CT in the diagnosis of COVID-19 patients based on the current literature, CT findings are not pathognomonic as it lacks specificity in differentiating imaging appearances caused by different types of pneumonia. Further, there is a relatively high percentage of normal CT scans. Use of CT as a first-line diagnostic or screening tool in COVID-19 is not recommended.

17 February 2018 in Journal of Medical Radiation Sciences
Verified
Journal Article
Open access
PDF file
ILIvan Lau
Ivan Lau
Zhonghua SunZhonghua Sun
Zhonghua Sun
Three‐dimensional (3D) printing has shown great promise in medicine with increasing reports in congenital heart disease (CHD). This systematic review aims to analyse the main clinical applications and accuracy of 3D printing in CHD, as well as to provide an overview of the software tools, time and costs associated with the generation of 3D printed heart models. A search of different databases was conducted to identify studies investigating the application of 3D printing in CHD. Studies based on patient's medical imaging datasets were included for analysis, while reports on in vitro phantom or review articles were excluded from the analysis. A total of 28 studies met selection criteria for inclusion in the review. More than half of the studies were based on isolated case reports with inclusion of 1–12 cases (61%), while 10 studies (36%) focused on the survey of opinion on the usefulness of 3D printing by healthcare professionals, patients, parents of patients and medical students, and the remaining one involved a multicentre study about the clinical value of 3D printed models in surgical planning of CHD. The analysis shows that patient‐specific 3D printed models accurately replicate complex cardiac anatomy, improve understanding and knowledge about congenital heart diseases and demonstrate value in preoperative planning and simulation of cardiac or interventional procedures, assist surgical decision‐making and intra‐operative orientation, and improve patient‐doctor communication and medical education. The cost of 3D printing ranges from USD 55 to USD 810. This systematic review shows the usefulness of 3D printed models in congenital heart disease with applications ranging from accurate replication of complex cardiac anatomy and pathology to medical education, preoperative planning and simulation. The additional cost and time required to manufacture the 3D printed models represent the limitations which need to be addressed in future studies.

1 July 2008 in European Journal of Radiology
Verified
Journal Article
Closed access
Zhonghua SunZhonghua Sun
Zhonghua Sun
CLChengHsun Lin
ChengHsun Lin
RDRobert Davidson
Robert Davidson
CDChiauhuei Dong
Chiauhuei Dong
YLYunchan Liao
Yunchan Liao

1 November 2006 in European Journal of Radiology
Verified
Journal Article
Closed access
Zhonghua SunZhonghua Sun
Zhonghua Sun
WJWen Jiang
Wen Jiang