1 May 2012 in British Journal of Radiology
Coronary CT angiography has been increasingly used in the diagnosis of coronary artery disease owing to rapid technological developments, which are reflected in the improved spatial and temporal resolution of the images. High diagnostic accuracy has been achieved with multislice CT scanners (64 slice and higher), and in selected patients coronary CT angiography is regarded as a reliable alternative to invasive coronary angiography. With high-quality coronary CT imaging increasingly being performed, patients can benefit from an imaging modality that provides a rapid and accurate diagnosis while avoiding an invasive procedure. Despite the tremendous contributions of coronary CT angiography to cardiac imaging, study results reported in the literature should be interpreted with caution as there are some limitations existing within the study design or related to patient risk factors. In addition, some attention must be given to the potential health risks associated with the ionising radiation received during cardiac CT examinations. Radiation dose associated with coronary CT angiography has raised serious concerns in the literature, as the risk of developing malignancy is not negligible. Various dose-saving strategies have been implemented, with some of the strategies resulting in significant dose reduction. The aim of this review is to present an overview of the role of coronary CT angiography on cardiac imaging, with focus on coronary artery disease in terms of the diagnostic and prognostic value of coronary CT angiography. Various approaches for dose reduction commonly recommended in the literature are discussed. Limitations of coronary CT angiography are identified. Finally, future directions and challenges with the use of coronary CT angiography are highlighted.
21 June 2018 in British Journal of Radiology
Objective:To investigate the use of shear wave elastography (SWE)-derived estimates of Young’s modulus (YM) as an indicator to detect abnormal renal tissue diagnosed by estimated glomerular filtration rate (eGFR).Methods:The study comprised 106 chronic kidney disease (CKD) patients and 203 control subjects. Conventional ultrasound was performed to measure the kidney length and cortical thickness. SWE imaging was performed to measure renal parenchymal stiffness. Diagnostic performance of SWE and conventional ultrasound were correlated with serum creatinine, urea levels and eGFR.Results:Pearson’s correlation coefficients revealed a negative correlation between YM measurements and eGFR (r = −0.576, p < 0.0001). Positive correlations between YM measurements and age (r = 0.321, p < 0.05), serum creatinine (r = 0.375, p < 0.0001) and urea (r = 0.287, p < 0.0001) were also observed. The area under the ROC curve for SWE (0.87) was superior to conventional ultrasound alone (0.35–0.37). The cut-off value of less or...
23 May 2015 in European Radiology
1 December 2009 in Australasian Physics & Engineering Sciences in Medicine
18 May 2006 in Radiation Protection Dosimetry
The systematic monitoring of image quality and radiation dose is an ultimate solution to ensuring the continuously high quality of mammography examination. At present several protocols exist around the world, and different test objects are used for quality control (QC) of the physical and technical aspects of screen-film mammography. This situation may lead to differences in radiation image quality and dose reported. This article reviews the global QC perspective for the physical and technical aspects of screen-film mammography with regard to image quality and radiation dose. It points out issues that must be resolved in terms of radiation dose and that also affect the comparison.
25 July 2014 in BioMedical Engineering OnLine
The phonetic properties of six Malay vowels are investigated using magnetic resonance imaging (MRI) to visualize the vocal tract in order to obtain dynamic articulatory parameters during speech production. To resolve image blurring due to the tongue movement during the scanning process, a method based on active contour extraction is used to track tongue contours. The proposed method efficiently tracks tongue contours despite the partial blurring of MRI images. Consequently, the articulatory parameters that are effectively measured as tongue movement is observed, and the specific shape of the tongue and its position for all six uttered Malay vowels are determined. Speech rehabilitation procedure demands some kind of visual perceivable prototype of speech articulation. To investigate the validity of the measured articulatory parameters based on acoustic theory of speech production, an acoustic analysis based on the uttered vowels by subjects has been performed. As the acoustic speech and articulatory parameters of uttered speech were examined, a correlation between formant frequencies and articulatory parameters was observed. The experiments reported a positive correlation between the constriction location of the tongue body and the first formant frequency, as well as a negative correlation between the constriction location of the tongue tip and the second formant frequency. The results demonstrate that the proposed method is an effective tool for the dynamic study of speech production.