PoWei Huang

Dr. PoWei Huang

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2020 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
PHPoWei Huang
PoWei Huang
BWBing-Jhang Wu
Bing-Jhang Wu
BWBing-Fei Wu
Bing-Fei Wu
Remote photoplethysmography (rPPG) is an unobtrusive solution to heart rate monitoring in drivers. However, disturbances that occur during driving such as driver behavior, motion artifacts, and illuminance variation complicate the monitoring of heart rate. Faced with disturbance, one commonly used assumption is heart rate periodicity (or spectrum sparsity). Several methods improve stability at the expense of tracking sensitivity for heart rate variation. Based on statistical signal processing (SSP) and Monte Carlo simulations, the outlier probability is derived and ADaptive spectral filter banks (AD) is proposed as a new algorithm which provides an explicable tuning option for spectral filter banks to strike a balance between robustness and sensitivity in remote monitoring for driving scenarios. Moreover, we construct a driving database containing over 23 hours of data to verify the proposed algorithm. The influence on rPPG from driver habits (both amateurs and professionals), vehicle types (compact cars and buses), and routes are also evaluated. In comparison to state-of-the-art rPPG for driving scenarios, the mean absolute error in the Passengers, Compact Cars, and Buses scenarios is 3.43, 7.85, and 5.02 beats per minute, respectively.

29 April 2019 in IEEE Access
Verified
Journal Article
Open access
BWBing-Fei Wu
Bing-Fei Wu
YCYun-Wei Chu
Yun-Wei Chu
PHPoWei Huang
PoWei Huang
MCMeng-Liang Chung
Meng-Liang Chung
The driver’s physiological status has enormous value to public traffic safety and cannot be ignored nowadays. In addition, heart rate (HR) is one of the most important indicators of human’s health status. When detecting the driver’s HR, using traditional contact-type devices might bring about the driver’s distraction or discomfort. On the contrary, the remote photoplethysmography (rPPG) technique is a better way to monitor a driver’s HR in vehicle applications simply by using a web-camera without interfering the driver. Most of the rPPG studies intended to reduce the interference caused by facial motion or luminance changes in the indoor or controlled scenario, but there are relatively fewer discussions on outdoor scenarios. Consequently, the purpose of this paper is to enhance the rPPG technique to make it suitable for the outdoor driving scenarios and for monitoring the driver’s HR in different weather conditions, including daytime and nighttime. We first utilize artificial neural network (ANN) and train multiple personalized ANN models for each driver. For predicting the drivers’ HR beat more precisely, we propose the approach, adaptive neural network model selection (ANNMS), which adaptively selects a personalized ANN model based on different noise conditions. Our algorithm eliminates the effect of noises caused by the variations of facial luminance in eight outdoor driving scenarios. The proposed driver’s HR beat monitoring system has been evaluated against the state-of-the-art rPPG techniques that are Chrominance signal-based (CHRO) and k-nearest neighbors-based (kNN) algorithms. Compared with the CHRO and kNN algorithms, the ANNMS reduces the mean absolute error from 14.71 bpm (CHRO) and 9.91 (kNN) to 4.51 bpm (ANNMS) and enhances the success-rate-10, the probability in which the absolute error is below 10 bpm, from 44.1% (CHRO) and 56.3% (kNN) to 91.5% (ANNMS).

7 April 2020 in IEEE Access
Verified
Journal Article
Open access
YTYin-Cheng Tsai
Yin-Cheng Tsai
PLPeng-Wen Lai
Peng-Wen Lai
PHPoWei Huang
PoWei Huang
TLTzu-Min Lin
Tzu-Min Lin
BWBing-Fei Wu
Bing-Fei Wu
In this paper, a vision-based physiological signal measurement system is proposed to instantly measure driver fatigue. A remote photoplethysmography (rPPG) signal is a type of physiological signal measured by a camera without any contact device, and it also retains the characteristics of the PPG, which is useful to evaluate fatigue. To solve the inconvenience caused by the traditional contact-based physiological fatigue detection system and to improve the accuracy, the system measures both the motional and physiological information by using one image sensor. In a practical application, the environmental noise would affect the measured signal, and therefore, we performed a preprocessing step on the signal to extract a clear signal. The experiment was designed in collaboration with Taipei Medical University, and a questionnaire-based method was used to define fatigue. The questionnaire that could directly react to the feeling of the subject was treated as our ground truth. The evaluated correlation was 0.89 and the root mean square error was 0.65 for ten-fold cross-validation on the dataset. The trend of driver fatigue could be evaluated without a contact device by the proposed system. This advantage ensures the safety of the driver and reliability of the system.

1 November 2017
Verified
Conference Paper
Closed access
PHPoWei Huang
PoWei Huang
CLChun-Hao Lin
Chun-Hao Lin
MCMeng-Liang Chung
Meng-Liang Chung
TLTzu-Min Lin
Tzu-Min Lin
BWBing-Fei Wu
Bing-Fei Wu
Recent years have seen increased attention being given to Blood Pressure (BP) monitoring. Among all kinds of measurements, the monitors based on Pulse Transit Time (PTT) have gain plenty of attention due to its continuous and cuffless features. Additionally, several studies proposed a fancy way to estimate photoplethysmography (PPG) signal simply via a regular webcam. Nevertheless, literatures on issues of integrating these two advanced techniques have emerged on a slowly and scattered way. Furthermore, accuracy of BP prediction model based on PTT is often limited due to the lack of data. To address the above-mentioned problems, we proposed an image based BP measurement algorithm using k-nearest neighbor and transfer learning results from MIMICII database to real task. The study also introduces newly defined PTT features which are especially suitable for image based PPG and domain adaptation. Compared with the state-of-the-art algorithm, root mean square error of SBP evaluation has been reduced from 15.08 to 14.02.

18 April 2018 in IEEE Access
Verified
Journal Article
Open access
BWBing-Fei Wu
Bing-Fei Wu
PHPoWei Huang
PoWei Huang
CLChun-Hsien Lin
Chun-Hsien Lin
MCMeng-Liang Chung
Meng-Liang Chung
TTTsong-Yang Tsou
Tsong-Yang Tsou
YWYu-Liang Wu
Yu-Liang Wu
Medical fields have seen increasing attention being given to image based heart rate measurement in recent years. One of the major limitations is motion artifacts of subject‘s head. Although there have been many studies focusing on signal extraction using different parameters and models, the development of frequency domain analysis is emerging slowly and moving in many directions. In the field of contact photoplethysmography (PPG), recent studies employed the acceleration signals to assist their spectral peak tracking algorithms. Inspired by the development of contact PPG, we are proposing a motion resistant spectral peak tracking (MRSPT) framework which eliminates the motion artifacts by integrating facial motion signals. The effectiveness of MRSPT coupled with the optimal iPPG signal has been tested against the state-of-the-art spectral peak tracking algorithms, multi-channel spectral matrix decomposition (MC-SMD), and the maximum peak selection coupled with optimal iPPG signal (Optimal MPS). Compared with MC-SMD and Optimal MPS, MRSPT uplifts the success rate-10 (success rate-5), the probability in which the absolute error is below ten (five) beats per minutes, from 54.7% (36.3%) with MC-SMD and 73.0% (61.3%) with Optimal MPS to 90.7% (75.7%) with MRSPT in motion scenarios where subject moves arbitrarily with different distance or lighting. MRSPT also enhances the success rate-10 (success rate-5) from 40.7% (26.3%) with MC-SMD and 57.4% (45.7%) with Optimal MPS to 73.4% (58.4%) with MRSPT in all seven motion conditions including driving and running. Averagely, the success rate-5 of Optimal MRSPT surpass the success rate-10 of both Optimal MPS and MC-SMD.

15 March 2017
Verified
Book Chapter
Closed access
PDF file
BWBing-Fei Wu
Bing-Fei Wu
YCYun-Wei Chu
Yun-Wei Chu
PHPoWei Huang
PoWei Huang
MCMeng-Liang Chung
Meng-Liang Chung
TLTzu-Min Lin
Tzu-Min Lin