The aerodynamic transfer of energy from glottal airflow to vocal fold tissue during phonation was explored using complementary synthetic and numerical vocal fold models. The synthetic model was fabricated using a flexible polyurethane rubber compound. The model size, shape, and material properties were generally similar to corresponding human vocal fold characteristics. Regular, self-sustained oscillations were achieved at a frequency of approximately 120 Hz. The onset pressure was approximately 1.2 kPa. A corresponding two-dimensional finite element model was developed using geometry definitions and material properties based on the synthetic model. The finite element model upstream and downstream pressure boundary conditions were based on experimental values acquired using the synthetic model. An analysis of the fully coupled fluid and solid numerical domains included flow separation and unsteady effects. The numerical results provided detailed flow data that was used to investigate aerodynamic energy transfer mechanisms. The results support the hypothesis that a cyclic variation of the orifice profile from a convergent to a divergent shape leads to a temporal asymmetry in the average wall pressure, which is the key factor for the achievement of self-sustained vocal fold oscillations.
30 June 2010 in Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences
Acoustic analogy methods are used as post-processing tools to predict aerodynamically generated sound from numerical solutions of unsteady flow. The Ffowcs Williams–Hawkings (FW–H) equation and related formulations, such as Farassat’s Formulations 1 and 1A, are among the commonly used analogies because of their relative low computation cost and their robustness. These formulations assume the propagation of sound waves in a medium at rest. The present paper describes a surface integral formulation based on the convective wave equation, which takes into account the presence of a mean flow. The formulation was derived to be easy to implement as a numerical post-processing tool for computational fluid dynamics codes. The new formulation constitutes one possible extension of Farassat’s Formulation 1 and 1A based on the convective form of the FW–H equation.
Tropocollagen types I and III were simultaneously fibrilized in vitro, and the differences between the geometric and mechanical properties of the heterotypic fibrils with different mixing ratios of tropocollagen III to I were investigated. Transmission electron microscopy was used to confirm the simultaneous presence of both tropocollagen types within the heterotypic fibrils. The incorporation of collagen III in I caused the fibrils to be thinner with a shorter D-banding than pure collagen I. Hertzian contact model was used to obtain the elastic moduli from atomic force microscope indentation testing using a force volume analysis. The results indicated that an increase in the percentage of tropocollagen III reduced the mechanical stiffness of the obtained fibrils. The mechanical stiffness of the collagen fibrils was found to be greater at higher loading frequencies. This observation might explain the dominance of collagen III over I in soft distensible organs such as human vocal folds.
25 October 2002 in The Journal of the Acoustical Society of America
The aerodynamic generation of sound during phonation was studied using direct numerical simulations of the airflow and the sound field in a rigid pipe with a modulated orifice. Forced oscillations with an imposed wall motion were considered, neglecting fluid–structure interactions. The compressible, two-dimensional, axisymmetric form of the Navier–Stokes equations were numerically integrated using highly accurate finite difference methods. A moving grid was used to model the effects of the moving walls. The geometry and flow conditions were selected to approximate the flow within an idealized human glottis and vocal tract during phonation. Direct simulations of the flow and farfield sound were performed for several wall motion programs, and flow conditions. An acoustic analogy based on the Ffowcs Williams–Hawkings equation was then used to decompose the acoustic source into its monopole, dipole, and quadrupole contributions for analysis. The predictions of the farfield acoustic pressure using the acoustic analogy were in excellent agreement with results from the direct numerical simulations. It was found that the dominant sound production mechanism was a dipole induced by the net force exerted by the surfaces of the glottis walls on the fluid along the direction of sound wave propagation. A monopole mechanism, specifically sound from the volume of fluid displaced by the wall motion, was found to be comparatively weak at the frequency considered (125 Hz). The orifice geometry was found to have only a weak influence on the amplitude of the radiated sound.
Non-compressible hemorrhage is an unmet clinical challenge that accounts for high mortality in trauma. Rapid pressurized blood flows under hemorrhage impair the function and integrity of hemostatic agents and the adhesion of bioadhesive sealants. Here, we report the design and performance of bioinspired microstructured bioadhesives, formed with a macroporous tough xerogel infused with functional liquids. The xerogel can rapidly absorb interfacial fluids such as whole blood and promote blood clotting, while the infused liquids facilitate interfacial bonding, sealing, and antibacterial function. Their synergy enables the bioadhesives to form tough adhesion on ex vivo human and porcine tissues and diverse engineered surfaces without the need for compression, as well as on-demand instant removal and storage stability. We demonstrate a significantly improved hemostatic efficacy and biocompatibility in rats and pigs compared to non-structured counterparts and commercial products. This work opens new avenues for the development of bioadhesives and hemostatic sealants.