Gexiang Zhang

Dr. Gexiang Zhang

School of Control Engineering CUIT, Chengdu University of Information Technology, Chengdu 610225, China
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2014 in International Journal of Neural Systems
Verified
Journal Article
Closed access
Gexiang ZhangGexiang Zhang
Gexiang Zhang
HRHaina Rong
Haina Rong
FNFerrante Neri
Ferrante Neri
Mario J. Pérez-JiménezMario J. Pérez-Jiménez
Mario J. Pérez-Jiménez

29 June 2010 in Journal of Heuristics
Verified
Journal Article
Closed access
PDF file
Gexiang ZhangGexiang Zhang
Gexiang Zhang

1 June 2019 in Information Sciences
Verified
Journal Article
Closed access
SCSheng Cao
Sheng Cao
Gexiang ZhangGexiang Zhang
Gexiang Zhang
PLPengfei Liu
Pengfei Liu
XZXiaosong Zhang
Xiaosong Zhang
FNFerrante Neri
Ferrante Neri

28 August 2014 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
TWTao Wang
Tao Wang
Gexiang ZhangGexiang Zhang
Gexiang Zhang
JZJunbo Zhao
Junbo Zhao
ZHZhengyou He
Zhengyou He
JWJun Wang
Jun Wang
Mario J. Pérez-JiménezMario J. Pérez-Jiménez
Mario J. Pérez-Jiménez
This paper proposes a graphic modeling approach, fault diagnosis method based on fuzzy reasoning spiking neural P systems (FDSNP), for power transmission networks. In FDSNP, fuzzy reasoning spiking neural P systems (FRSN P systems) with trapezoidal fuzzy numbers are used to model candidate faulty sections and an algebraic fuzzy reasoning algorithm is introduced to obtain confidence levels of candidate faulty sections, so as to identify faulty sections. FDSNP offers an intuitive illustration based on a strictly mathematical expression, a good fault-tolerant capacity due to its handling of incomplete and uncertain messages in a parallel manner, a good description for the relationships between protective devices and faults, and an understandable diagnosis model-building process. To test the validity and feasibility of FDSNP, seven cases of a local subsystem in an electrical power system are used. The results of case studies show that FDSNP is effective in diagnosing faults in power transmission networks for single and multiple fault situations with/without incomplete and uncertain SCADA data, and is superior to four methods, reported in the literature, in terms of the correctness of diagnosis results.

30 October 2015 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
JZJunbo Zhao
Junbo Zhao
Gexiang ZhangGexiang Zhang
Gexiang Zhang
MSMassimo La Scala
Massimo La Scala
Zhaoyang DongZhaoyang Dong
Zhaoyang Dong
CCChen Chen
Chen Chen
JWJianhui Wang
Jianhui Wang
Successful detection of false data injection attacks (FDIAs) is essential for ensuring secure power grids operation and control. First, this paper extends the approximate dc model to a more general linear model that can handle both supervisory control and data acquisition and phasor measurement unit measurements. Then, a general FDIA based on this model is derived and the error tolerance of such attacks is discussed. To detect such attacks, a method based on short-term state forecasting considering temporal correlation is proposed. Furthermore, a statistics-based measurement consistency test method is presented to check the consistency between the forecasted measurements and the received measurements. This measurement consistency test is further integrated with ∞-norm and L 2 -norm-based measurement residual analysis to construct the proposed detection metric. The proposed detector addresses the shortcoming of previous detectors in terms of handling critical measurements. Besides, the removal problem of attacked measurements, which may cause the system to become unobservable, is addressed effectively by the proposed method through forecasted measurements. Numerical tests on IEEE 14-bus and 118-bus test systems verify the effectiveness and performance of the proposed method.

25 May 2015 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
JZJunbo Zhao
Junbo Zhao
Gexiang ZhangGexiang Zhang
Gexiang Zhang
KDKaushik Das
Kaushik Das
GKGeorge N. Korres
George N. Korres
NMNikolaos M. Manousakis
Nikolaos M. Manousakis
ZHZhengyou He
Zhengyou He
Accurate real-time states provided by the state estimator are critical for power system reliable operation and control. This paper proposes a novel phasor measurement unit (PMU)-based robust state estimation method (PRSEM) to real-time monitor a power system under different operation conditions. To be specific, an adaptive weight assignment function to dynamically adjust the measurement weight based on the distance of big unwanted disturbances from the PMU measurements is proposed to increase algorithm robustness. Furthermore, a statistical test-based interpolation matrix H updating judgment strategy is proposed. The processed and resynced PMU information are used as priori information and incorporated to the modified weighted least square estimation to address the measurements imperfect synchronization between supervisory control and data acquisition and PMU measurements. Finally, the innovation analysis-based bad data (BD) detection method, which can handle the smearing effect and critical measurement errors, is presented. We evaluate PRSEM by using IEEE benchmark test systems and a realistic utility system. The numerical results indicate that, in short computation time, PRSEM can effectively track the system real-time states with good robustness and can address several kinds of BD.