This work demonstrates the ability of the Ion-Sensitive Field-Effect Transistor (ISFET)-based immunosensor to detect antibodies against the human leukocyte antigen (HLA) and the major histocompatibility complex class-I-related chain A (MICA). The sensing membrane of the ISFET devices was modified and functionalized using an APTES-GA strategy. Surface properties, including wettability, surface thickness, and surface topology, were assessed in each module of the modification process. The optimal concentrations of HLA and MICA proteins for the immobilization were 10 and 50 μg/mL. The dose-response curve showed a detection range of 1.98–40 µg/mL for anti-HLA and 5.17–40 µg/mL for anti-MICA. The analytical precision (%CV) was found to be 10.69% and 8.92% for anti-HLA and -MICA, respectively. Moreover, the electrical signal obtained from the irrelevant antibody was considerably different from that of the specific antibodies, indicating the specific binding of the relevant antibodies without noise interference. The sensitivity and specificity in the experimental setting were established for both antibodies (anti-HLA: sensitivity = 80.00%, specificity = 86.36%; anti-MICA: sensitivity = 86.67%, specificity = 88.89%). Our data reveal the potential of applying the ISFET-based immunosensor to the detection of relevant anti-HLA and -MICA antibodies, especially in the field of kidney transplantation.
13 March 2020 in Japanese Journal of Applied Physics
This paper presents a modification of a Si 3 N 4 Polyvinyl chloride (PVC) membrane on a surface of an ion selective field effect transistor (ISFET) using silane with two different functional groups for comparison of nitrate sensing characteristics. Effects of amino (NH 2 ) and thiol groups (SH) toward structures and characteristics of nitrate sensors were analyzed using the following techniques: ellipsometry, scanning electron microscope (SEM), infrared spectroscopy (FTIR), zeta potential and electrochemical impedance spectroscopy (EIS). After surface modification, the thickness of the silane layers for both cases were similar with uniform surface topology. Absolute zeta potentials of PVC ion-selective membrane (7.65 mV) and Si 3 N 4 surface modification with MPTMS (−51.46 mV) reflected the surface functional group and showed that membranes could be bonded to the PVC ion-selective membrane. Since APTMS produced higher EIS than MPTMS, the resulting nitrate sensors modified by MPTMS had higher sensitivity than the sensors with APTMS. Finally, the modified sensors had a useful life time of 3 months.
In addition to their use as an additive to improve physical properties of solvent polymeric membranes, plasticizers have a considerable impact on the specificity and sensitivity of membrane-modified electrochemical sensors. In this work, we aim at the hybridization of two different plasticizers using the electropolymerization technique in the development of a cadmium(II)-selective electrochemical sensor based on screen-printed gold electrode along with cyclic voltammetric measurement. At this point, we first screen for the primary plasticizer yielding the highest signal using cyclic voltammetry followed by pairing it with the secondary plasticizers giving rise to the most sensitive current response. The results show that the hybridization of DOS and TOTM with 3:1 weight ratio (~137.7-μm-thick membrane) renders a signal that is >26% higher than that from the sensor plasticized by DOS per se in water. The solution of 0.1 mM hydrochloric acid (pH 4) is the optimal supporting electrolyte. In addition, hybrid plasticizers have adequate redox capacity to induce cadmium(II) transfer from bulk solution to the membrane/water interfaces. Conversion of voltammetric signals to semi-integral currents results in linearity with cadmium(II) concentration, indicating the irreversible cadmium(II) transfer to the membrane. The DOS:TOTM hybrid sensor also exhibits high sensitivity, with a limit of detection (LOD) and limit of quantitation (LOQ) of 95 ppb and 288 ppb, respectively, as well as greater specificity towards cadmium(II) than that obtained from the single plasticizer sensor. Furthermore, recovery rates of spiked cadmium(II) in water samples were higher than 97% using the hybrid plasticizer sensor. Unprecedentedly, our work reports that the hybridization of plasticizers serves as ion-to-electron transducer that can improve the sensor performance in cadmium(II) detection.