Jing Zheng

Dr. Jing Zheng

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JZJing Zheng
Jing Zheng
HHHai Huang
Hai Huang
JPJie Pan
Jie Pan
The electrical-mechanical dynamics of a transformer may be described by a model with cascade-connected linear and nonlinear parts. This paper shows that mechanical faults have a significant influence on the linear part of the model. A change in the system order of the linear part of the model can be used as an indicator of variance in a transformer's physical characteristics. A technique based on the Lipschitz criterion is developed to estimate the system order, which is then used for detecting changes in the vibration of the system caused by mechanical faults in the windings. The proposed method is tested on a three-phase power transformer, demonstrating promising detection of faults in transformer windings.

28 July 2019 in Electronics
Verified
Journal Article
Open access
PDF file
YHYiwei Hu
Yiwei Hu
JZJing Zheng
Jing Zheng
HHHai Huang
Hai Huang
Vibration analysis is one of the important tools for the transformer winding faults diagnosis. Previous researchers have proved that the vibration spatial distribution of the winding is significantly influenced by the winding defects for the open circuit condition. In order to study the effects of the loading current on the winding vibrations under different mechanical conditions, experiments were designed and operated on a three-phase transformer winding to analyze the winding vibration distribution under different winding defect cases. Further, to study to what extent the mechanical defects and the loading current influence characteristics of the vibration distribution on the tank, the tank vibration distribution under various winding defects and different loading currents were also measured and discussed. In addition, the possibility of detection of transformer winding faults based on tank vibration spatial distribution characteristics was also discussed.

12 May 2023 in Frontiers in Psychology
Verified
Journal Article
Open access
YSYifan Sun
Yifan Sun
TLTian Lu
Tian Lu
XWXuanyi Wang
Xuanyi Wang
WCWanlin Chen
Wanlin Chen
SCShulin Chen
Shulin Chen
JZJing Zheng
Jing Zheng
Background: Previous studies suggest that physiological feedback can be an effective method for emotion regulation (ER). However, studies on the specific effects of physiological feedback have shown conflicting results due to inconsistencies in study designs. Therefore, we present this systematic review to further validate the effectiveness of physiological feedback for ER, clarify its specific effects, as well as summarize the factors that influence its effectiveness.Method: This systematic review following PRISMA guidelines covers all studies using physiological feedback in emotions. A literature search was conducted in Web of Science, PubMed, PsychINFO, China National Knowledge Infrastructure, and WANFANG DATA. And a standardized quality assessment was performed.Results: We identified 27 relevant articles (25 studies), and the majority of these studies showed a significant regulatory effect of physiological feedback on different emotions. The feedback's content, explanation, authenticity, real-time capability, and modality were the key factors that influenced its effects, and this technology will achieve its optimal ER effect when these factors are considered comprehensively.Conclusions: These findings further confirmed the effectiveness of physiological feedback as an ER method, as well as providing key factors that should be addressed in its application. Meanwhile, due to the limitations of these studies, more well-designed studies are still needed.

27 June 2024 in Electronics
Verified
Journal Article
Open access
PDF file
YYYao Yuan
Yao Yuan
JZJiafeng Zhao
Jiafeng Zhao
KHKaixing Hong
Kaixing Hong
NWNing Wang
Ning Wang
JZJing Zheng
Jing Zheng
This paper proposes an operation modal analysis (OMA)-based approach to obtain a transformer’s mechanical condition from vibrations during the transformer’s transient processes, such as short-circuit and power-off conditions. Such processes generate a short transient vibration response, which yields a spectrum with poor frequency resolution. Vibration before the transient process could be included to increase the signal length; however, this would introduce a forced vibration component into the spectrum, making it challenging to distinguish the modal frequencies. To overcome these problems, a time–frequency analysis-based algorithm is proposed to extract the modal frequency spectrum from the vibration signal with the high-frequency resolution, providing clearer insight into the mechanical condition of the transformer. A faulty-state indicator is then proposed based on the similarity between the extracted modal spectrum and the initial modal spectrum obtained under a healthy state. To validate the proposed method, laboratory experiments were conducted under short-circuit and power-off conditions. Two mechanical faults—the looseness of the winding clamping and winding deformation—are introduced. The results show that both faults will cause variations in the modal frequency spectrum, leading to significant decreases in the indicator value. In summary, the proposed method can effectively evaluate a transformer’s mechanical condition in an OMA setting.

30 November 2023 in Sensors
Verified
Journal Article
Open access
PDF file
XJXishan Jiang
Xishan Jiang
JZJing Zheng
Jing Zheng
NWNing Wang
Ning Wang
JPJie Pan
Jie Pan
This paper investigates the properties of a mass−attached piezoelectric stack actuator and analyzes its sensitivity, which is defined as the spectrum of the driving force (the output) caused by a single−frequency voltage (the input). The force spectrum is utilized because of the nonlinear hysteresis effect of the piezoelectric stack. The sensitivity analysis shows that the nonlinear dynamics of the actuator can be interpreted as a cascade of two subsystems: a nonlinear hysteresis subsystem and a linear mechanical subsystem. Analytical solutions of the nonlinear differential equations are proposed, which show that the nonlinear transformation can be described by a steady−state mapping of a single−frequency voltage input to a multiple−frequency driving force at the driving frequency and its odd harmonics. The steady−state sensitivity is then determined by the response of the mechanical subsystem to the line spectrum of the driving force. The maximum sensitivity can be achieved by setting the frequency of the input voltage close to the natural frequency of the mechanical subsystem. The analytical model is also validated by a numerical model and experimental results and it may be used for the analysis and design of piezoelectric actuators with different structural configurations.

6 March 2019 in Electronics
Verified
Journal Article
Open access
LLLingzhi Li
Lingzhi Li
XDXuhao Du
Xuhao Du
JPJie Pan
Jie Pan
AKAdrian Keating
Adrian Keating
DMDavid Matthews
David Matthews
JZJing Zheng
Jing Zheng
In this paper, the magnetic flux density distribution on the cross-sections of a transformer core is studied. The core for this study consists of two identical U-shaped cores joint at their open surfaces with known air gaps. The magnetic flux density at one of their joint boundary surfaces was measured for different air gaps. A finite element model (FEM) was built to simulate the magnetic flux density and compared with experiment data. Using the validated FEM, the distributed magnetic flux density on the cross-section of the core structure can be obtained when the air gap approaches zero. An engineering model of the density based on the Ampere’s circuit law was also developed and used to explain the relationship between air gap and mean magnetic flux density on the cross-section. The magnetic flux density on the cross-section was found to have a convex-shaped distribution and could be described by an empirical formula. Using this approach, the magnetic flux density distribution in cores with different interlayer insulation was obtained and discussed. This method could also examine the leakage of magnetic flux density in the air gap region when the distance is non-zero, and the relationship between the leakage field and the field in the core structure. The proposed method and model can provide a more detailed understanding for the magnetic field of transformer cores and potential application in designing quiet transformers and condition monitoring.