you Fu

Dr. you Fu

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 October 2016 in Advances in Mechanical Engineering
Verified
Journal Article
Open access
JJJin Jiang
Jin Jiang
YFyou Fu
you Fu
LZLisheng Zhang
Lisheng Zhang
YLYanhui Li
Yanhui Li
WJWeidong Ji
Weidong Ji
YLYameng Liu
Yameng Liu
In this article, two fluid conservation equations of gas–liquid two-phase transient flows are deduced with an improved mass transfer model between two phases and applied to liquid-column separation transients in pipelines. A new description of gas–liquid two-phase bubbly flow numerical calculation is structured with difference method of the Steger–Warming flux vector splitting method which is combined with NND scheme. Two experiments are chosen to validate the applicability and accuracy of the two-phase flow model: (1) Simpson’s valve closure water hammer experiment and (2) our select water hammer experiment: the power failure in the horizontal pipeline pump system experiment. Results show that a reasonable agreement is achieved by comparing to the experimental results. This method is stated to be capable of capturing shock waves and the interface mass exchange during transient process in bubble flow while suppressing calculation oscillation problem.

14 September 2024 in Processes
Verified
Journal Article
Open access
PDF file
YFyou Fu
you Fu
LDLingling Deng
Lingling Deng
This paper focuses on a vertical axial flow pump and employs a 1D-3D coupling method to investigate the effects of different gate pre-opening angles on the internal and external flow characteristics of the axial flow pump during startup. Through comparative analysis, the following conclusions are drawn: In the study, a fully open gate is defined as 1, while a fully closed gate is defined as 0. When starting the axial flow pump with different valve pre-opening degrees, backflow occurs within the first 20 s of startup, and the backflow rate inside the pump gradually increases with the increase in the valve pre-opening degree. At a valve pre-opening degree of 0.6, the maximum backflow rate inside the pump reaches 5.89% of the rated flow rate. When starting the pump with the valve fully open, the maximum backflow rate reaches 10.98% of the rated flow rate, and the efficiency is affected by the backflow rate. The valve pre-opening degree has little impact on the axial force acting on the impeller during startup. When starting with a valve pre-opening degree of 0.6, the internal pressure difference in the pump is minimized. Within the first 20 s of startup, the internal pressure difference in the impeller is 28.96% higher and the flow velocity is 14.62% higher with valve pre-opening degrees of 0.8 and 1.0 compared to a 0.6 degree opening. During the initial stage of pump startup, with valve pre-opening degrees of 0.8 and 1.0, the pressure fluctuation amplitude inside the pump is minimal, with maximum relative amplitudes of only 0.621 and 0.525, which are 41.00% and 28.51% lower than the maximum amplitudes at 0 and 0.2 degrees, respectively. In summary, the peak pressure inside the pump is minimized when the valve pre-opening degree is around 0.8, while the pressure difference and flow velocity are relatively lower at a pre-opening degree of 0.6. It is recommended to start the pump with a valve pre-opening degree of around 0.6 to 0.8.

18 March 2026 in Journal of the Brazilian Society of Mechanical Sciences and Engineering
Verified
Journal Article
Closed access
PDF file
YFyou Fu
you Fu
FSFengyi Shen
Fengyi Shen
MQMulan Qi
Mulan Qi

11 February 2020 in Mathematical Problems in Engineering
Verified
Journal Article
Open access
PDF file
YFyou Fu
you Fu
ZXZhaopeng Xie
Zhaopeng Xie
WZWeiguo Zhao
Weiguo Zhao
In this paper, the seven-equation two-fluid flow model is streamlined to a five-equation numerical calculation method. This method is applied to predict the wave attenuation of the cavitation jet. Compared with 9 different experimental schemes in two separate laboratories, it is found that the velocity flow characteristics are different from normal transient flow when the cavitation jet is formed in the pipeline. Such a difference in velocity flow characteristics will cause changes in the prediction deviation of pressure response time and amplitude. A numerical method for predicting the attenuation of pressure fluctuation with the cavitation jet is presented taken into account these flow characteristics. In this method, the unsteady friction model is opened after the jet wave transmits 3–5 cycles, and the cavitation jet wave attenuation is well simulated. This calculation method could provide a research basis for pipeline leakage, vibration, noise, and other fields that need accurate pressure signals.

1 August 2025 in Physics of Fluids
Verified
Journal Article
Closed access
PQPan Qiang
Pan Qiang
WHWei Han
Wei Han
RLRennian Li
Rennian Li
YFyou Fu
you Fu
Mitigating intermittent gas blockage in helical axial-flow multiphase pumps under high gas void fraction conditions is crucial for improving pump efficiency and ensuring pipeline safety. This study applies the jet flow field control concept, using a tandem cascade structure to suppress the gas-blocking phenomenon and enhance pump performance. Employing a Latin hypercube sampling-based experimental design methodology, the research investigates the influence of tandem cascade configuration and geometric parameters on pump performance. Special emphasis is placed on three critical factors: the front blade camber angle, the rear blade camber angle, and the approximate attack angle of the rear blade. A mathematical model for the pump head under tandem cascade jet flow is established, along with a newly defined parameter that characterizes the gas aggregation scale at the trailing edge. Results show that pump efficiency exhibits higher sensitivity to front blade camber angle, whereas changes in rear blade angle predominantly affect head characteristics. The tandem cascade configuration demonstrates particularly pronounced efficiency improvements under high gas volume fraction conditions. Increasing front blade camber angle reduces pressure gradient in the rear impeller section, thus alleviating gas-phase aggregation; however, the enlarged front blade wake region introduces additional flow losses downstream. The rear blade's approximate attack angle significantly influences flow impingement on both pressure and suction surfaces of the rear blade by altering inflow conditions. When the rear blade's approximate attack angle is negative and its value is smaller, the loss of work performed by the front blade increases, with the optimal pump efficiency occurring when the value is zero.

24 August 2024 in Water
Verified
Journal Article
Open access
PDF file
KWKan Wang
Kan Wang
YFyou Fu
you Fu
JJJin Jiang
Jin Jiang
In this study, a one-dimensional mathematical model based on rigid theory is developed to evaluate the maximum water filling flow rate and filling time of closed pipeline water supply systems during rapid-filling processes. Polynomial fitting is utilized for prediction, and numerical simulation results are analyzed to understand the variations in maximum water filling flow rate, filling time, and pressure with respect to opening valve time, air valve area, filling head, and segmented filling pipe length. The findings highlight the significant impact of the filling head on the maximum water filling flow rate, while the filling time is predominantly influenced by the gas discharge coefficient. Rapid changes occur only at the initial stage of rapid filling, reaching the maximum value with a very high acceleration (around t = 4 s). It is observed that pressure fluctuations in the gas–liquid two-phase flow inside the pipeline lead to velocity differences and periodic changes in gas pressure opposite to the filling head. When the gas discharge coefficient reaches approximately 0.3, pressure variation within the water supply system diminishes, and the time and flow rate required for pipeline filling become independent of the discharge coefficient. This study suggests the use of a segmented filling approach to ensure the effectiveness and stability of pipeline filling.