Konstantina Vasilatou

Dr. Konstantina Vasilatou

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2020 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
ESEric Sauvageat
Eric Sauvageat
YZYanick Zeder
Yanick Zeder
KAKevin Auderset
Kevin Auderset
BCBertrand Calpini
Bertrand Calpini
BCBernard Clot
Bernard Clot
KVKonstantina Vasilatou
Konstantina Vasilatou
We present the first validation of the Swisens Poleno, currently the only operational automatic pollen monitoring system based on digital holography. The device provides in-flight images of all coarse aerosols, and here we develop a two-step classification algorithm that uses these images to identify a range of pollen taxa. Deterministic criteria based on the shape of the particle are applied to initially distinguish between intact pollen grains and other coarse particulate matter. This first level of discrimination identifies pollen with an accuracy of 96 %. Thereafter, individual pollen taxa are recognized using supervised learning techniques. The algorithm is trained using data obtained by inserting known pollen types into the device, and out of eight pollen taxa six can be identified with an accuracy of above 90 %. In addition to the ability to correctly identify aerosols, an automatic pollen monitoring system needs to be able to correctly determine particle concentrations. To further verify the device, controlled chamber experiments using polystyrene latex beads were performed. This provided reference aerosols with traceable particle size and number concentrations in order to ensure particle size and sampling volume were correctly characterized.

15 November 2018 in Aerosol Science and Technology
Verified
Journal Article
Open access
MEMichaela N. Ess
Michaela N. Ess
KVKonstantina Vasilatou
Konstantina Vasilatou
Flame-generated soot from miniCAST burners is increasingly being used in academia and industry as engine exhaust soot surrogate for atmospheric studies and instrument calibration. Previous studies have found that EC (elemental carbon) content of miniCAST soot is proportional to the mean particle size. Here, the characterization of a prototype miniCAST generator (5201 Type BC), which was designed to decouple the soot composition from the particle size and produce soot particles with high EC and BC content in a large size range, is reported. This prototype may operate either in a diffusion-flame or a partially premixed-flame mode, an option that was not available in former models. It was confirmed that soot properties, such as EC content and Ångström absorption exponent (AAE), were linked to the overall flame composition. In particular, combustion under fuel-rich conditions provided particles with size coupled to the EC fraction and AAE, i.e. smaller particles exhibited a lower EC fraction and higher AAE. In contrast, with fuel-lean diffusion flames and especially with premixed flames under near overall stoichiometric conditions small particles (down to 30 nm) with high EC/TC ratios (>60%) and low AAE (≈1.4) could be generated even without any thermal after-treatment. This new source might thus serve in the future as a useful surrogate for engine exhaust emissions and help to improve calibration procedures of common aerosol instruments.

27 June 2022 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
LDLuka Drinovec
Luka Drinovec
UJUroš Jagodič
Uroš Jagodič
LPLuka Pirker
Luka Pirker
MŠMiha Škarabot
Miha Škarabot
MKMario Kurtjak
Mario Kurtjak
Grisa MocnikGrisa Mocnik
Grisa Mocnik
There exists a lack of aerosol absorption measurement techniques with low uncertainties and without artefacts. We have developed the two-wavelength Photothermal Aerosol Absorption Monitor (PTAAM-2λ), which measures the aerosol absorption coefficient at 532 and 1064 nm. Here we describe its design, calibration and mode of operation and evaluate its applicability, limits and uncertainties. The 532 nm channel was calibrated with ∼ 1 µmol mol−1 NO2, whereas the 1064 nm channel was calibrated using measured size distribution spectra of nigrosin particles and a Mie calculation. Since the aerosolized nigrosin used for calibration was dry, we determined the imaginary part of the refractive index of nigrosin from the absorbance measurements on solid thin film samples. The obtained refractive index differed considerably from the one determined using aqueous nigrosin solution. PTAAM-2λ has no scattering artefact and features very low uncertainties: 4 % and 6 % for the absorption coefficient at 532 and 1064 nm, respectively, and 9 % for the absorption Ångström exponent. The artefact-free nature of the measurement method allowed us to investigate the artefacts of filter photometers. Both the Aethalometer AE33 and CLAP suffer from cross-sensitivity to scattering – this scattering artefact is most pronounced for particles smaller than 70 nm. We observed a strong dependence of the filter multiple scattering parameter on the particle size in the 100–500 nm range. The results from the winter ambient campaign in Ljubljana showed similar multiple scattering parameter values for ambient aerosols and laboratory experiments. The spectral dependence of this parameter resulted in AE33 reporting the absorption Ångström exponent for different soot samples with values biased 0.23–0.35 higher than the PTAAM-2λ measurement. Photothermal interferometry is a promising method for reference aerosol absorption measurements.

1 February 2022 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
DKDaniel Martin Kalbermatter
Daniel Martin Kalbermatter
Grisa MocnikGrisa Mocnik
Grisa Mocnik
LDLuka Drinovec
Luka Drinovec
BVBradley Visser
Bradley Visser
JRJannis Röhrbein
Jannis Röhrbein
KVKonstantina Vasilatou
Konstantina Vasilatou
We report on an inter-comparison of black-carbon- and aerosol-absorption-measuring instruments with laboratory-generated soot particles coated with controlled amounts of secondary organic matter (SOM). The aerosol generation setup consisted of a miniCAST 5201 Type BC burner for the generation of soot particles and a new automated oxidation flow reactor based on the micro smog chamber (MSC) for the generation of SOM from the ozonolysis of α-pinene. A series of test aerosols was generated with elemental to total carbon (EC / TC) mass fraction ranging from about 90 % down to 10 % and single-scattering albedo (SSA at 637 nm) from almost 0 to about 0.7. A dual-spot Aethalometer AE33, a photoacoustic extinctiometer (PAX, 870 nm), a multi-angle absorption photometer (MAAP), a prototype photoacoustic instrument, and two prototype photo-thermal interferometers (PTAAM-2λ and MSPTI) were exposed to the test aerosols in parallel. Significant deviations in the response of the instruments were observed depending on the amount of secondary organic coating. We believe that the setup and methodology described in this study can easily be standardised and provide a straightforward and reproducible procedure for the inter-comparison and characterisation of both filter-based and in situ black-carbon-measuring (BC-measuring) instruments based on realistic test aerosols.

8 December 2021 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
GLGian Lieberherr
Gian Lieberherr
KAKevin Auderset
Kevin Auderset
BCBertrand Calpini
Bertrand Calpini
BCBernard Clot
Bernard Clot
BCBenoît Crouzy
Benoît Crouzy
KVKonstantina Vasilatou
Konstantina Vasilatou
This study presents the first reference calibrations of three commercially available bioaerosol detectors. The Droplet Measurement Technologies WIBS-NEO (new version of the wideband integrated bioaerosol spectrometer), Plair Rapid-E, and Swisens Poleno were compared with a primary standard for particle number concentrations at the Federal Institute for Metrology (METAS). Polystyrene (PSL) spheres were used to assess absolute particle counts for diameters from 0.5 to 10 µm. For the three devices, counting efficiency was found to be strongly dependent on particle size. The results confirm the expected detection range for which the instruments were designed. While the WIBS-NEO achieves its highest efficiency with smaller particles, e.g. 90 % for 0.9 µm diameter, the Plair Rapid-E performs best for larger particles, with an efficiency of 58 % for particles with a diameter of 10 µm. The Swisens Poleno is also designed for larger particles but operates well from 2 µm. However, the exact counting efficiency of the Poleno could not be evaluated as the cut-off diameter range of the integrated concentrator unit was not completely covered. In further experiments, three different types of fluorescent particles were tested to investigate the fluorescent detection capabilities of the Plair Rapid-E and the Swisens Poleno. Both instruments showed good agreement with the reference data. While the challenge to produce known concentrations of larger particles above 10 µm or even fresh pollen particles remains, the approach presented in this paper provides a potential standardised validation method that can be used to assess counting efficiency and fluorescence measurements of automatic bioaerosol monitoring devices.

12 April 2021 in Aerosol Science and Technology
Verified
Journal Article
Open access
MEMichaela N. Ess
Michaela N. Ess
MBMichele Bertò
Michele Bertò
MIMartin Irwin
Martin Irwin
RMRobin L. Modini
Robin L. Modini
MGMartin Gysel-Beer
Martin Gysel-Beer
KVKonstantina Vasilatou
Konstantina Vasilatou
The miniCAST 5201 BC generator is a novel soot generator able to produce soot particles with a wide range of properties in a stable and reproducible manner. In this study, particles generated with diffusion and premixed flames were comprehensively analyzed, with a special focus on particle morphology, nanostructure, and optical properties. It was found that aggregate BC particles with a mean electrical mobility diameter of about 160 nm generated with an overall near-stoichiometric diffusion flame consist of primary particles with turbostratic layers and onion-like structures. Moreover, they possessed an absorption Ångström exponent (AAE) close to 1, low single scattering albedo (SSA), and a mass absorption cross section MAC870nm,total (calculated from photoacoustic absorption coefficient and total particle mass) of 4.3 m2/g. With premixed flames under fuel-lean conditions, particles with mean mobility diameters of 50 nm, 75 nm and 100 nm could be generated with high elemental carbon to total carbon mass fractions (> 85%). These particles had a high structural order, exhibited an absorption AAE of 1.1-1.2, SSA and MAC870nm,total of 3.0-3.3 m2/g. The similarities of the properties of the miniCAST generated soot particles to real-world engine emitted soot particles indicate that the miniCAST 5201 BC generator is a very promising source of reference aerosols for the calibration of black carbon (BC) diagnostic instruments and engine-exhaust particle counters.